New Radon MItigation Trickle Technology

Views:
 
     
 

Presentation Description

New "Trickle" technology provides accurate, adjustable radon reduction. Quiet, minimal mold risk. Excellent buyer acceptance

Comments

By: GreyP (3 month(s) ago)

For help with radon mitigation in Raleigh, asbestos abatement, or mold removal, http://www.remtechenvironmental.com offers a full list of services.

By: HaroldJoh (20 month(s) ago)

We used this radon detection company in Raleigh NC to check our home for this dangerous substance http://raleighradon.com/Test.htm

Presentation Transcript

New Radon Mitigation Technology : 

New Radon Mitigation Technology Neat, Simple, Effective Preferred by Buyers and Sellers in Hot, Humid, Climates RadonMan, Inc. www.radonman.net 239 435-0774

Radon Evolution in Florida : 

Radon Evolution in Florida Most radon systems in Florida are identical to and being installed in the same way they were installed twenty-five years ago. The radon mitigators did and still do usually fail to warn the homeowners that the systems could create new mold problems by increasing indoor relative humidity.

Radon Evolution in Florida : 

Radon Evolution in Florida Most of those systems deliver dirty, unfiltered air and from 40 to 100 pounds of water vapor a day into a home, to soak into clothes, furniture, books, walls, wood, artwork, etc. ERVs, Energy Recovery Ventilators always increase moisture loads...ask the ERV manufacturers, and they will tell you the truth about how ERVs increase indoor moisture in hot, humid climates. ERVs work very well in cold climates.

Radon Evolution in Florida : 

Radon Evolution in Florida In hot, humid climates, it is not unusual for air conditioners to be overloaded with moisture and unable to maintain dry interiors... and for furnishings to soak up the excess moisture

Radon Evolution In Florida : 

Radon Evolution In Florida RadonMan saw radon systems that were complicated, unreliable, difficult to operate and that they caused mold, moisture and odor problems It was not unusual that home owners turned the systems off because of noise, dirt, high humidity and mold. Because the radon systems were so unsatisfactory.

Old Style Air Intake : 

Old Style Air Intake Clothes Dryer Exhaust Hood Sometimes fitted with a makeshift filter Poor paint adhesion Duct tape hurricane cover-up

Another Old Style Air Intake : 

Another Old Style Air Intake Usually has no filter at all Sometimes has a 1/8 inch thick sponge filter four inches square Any insect smaller than the grid is chopped to pieces and dumped inside the home

New Style Air Intake (RadonMan) : 

New Style Air Intake (RadonMan) Heavy gauge aluminum CNC (computer) laser cut and bent Permanent polyester finish Can be painted Hood manually closes for instant hurricane protection

Old Style Filter : 

Old Style Filter Plastic grid Two cut-to-fit layers 4”X4” hog's hair 4”X4” non-woven polyester 16 square inches filter area Disassemble and Wash every month

New Style Air Filter (RadonMan) : 

New Style Air Filter (RadonMan) Polyester/fiberglass 70 pleats Rubber gasket 1,500 square inches of filter area Change in two minutes with no tools necessary Filter life: two years

Comparison : 

Comparison No words necessary

Old Style “Pulse” Blower : 

Old Style “Pulse” Blower Noisy blower toggles off and on full speed with $6.00 lamp timer Single speed 100 CFM blower Dumps high humidity air into a closed laundry closet Illegally wired with an extension cord

New Trickle Ventilator (RadonMan) : 

New Trickle Ventilator (RadonMan) Quiet Adjustable trickle rate 15 to 65 CFM allows easy radon level adjustment Requires no duct Electronically controlled variable speed blower Good for 4.0 to 7 pCi/l

Old Style Control Panel : 

Old Style Control Panel Table lamp timer ($6) Subject to jamming in “on” position How do you turn it off when you leave? On when you return?

New Style Control Panel (RadonMan) : 

New Style Control Panel (RadonMan) Convenient Green system OK light One finger rocker switch Concealed low voltage wiring

Old Style System Indicator : 

Old Style System Indicator How do you read it? What does it mean? Will it give false indications?

New Style System Indicator (RadonMan) : 

New Style System Indicator (RadonMan) Green = system functioning Red = system off

New RadonMan Precision Trickle Mitigation System : 

New RadonMan Precision Trickle Mitigation System The simple system with full, easy control For radon levels of 4.0 to 7.0 picoCuries per liter Includes six point air conditioner check and tuning to ensure sufficient dehumidification performance Superior home buyer acceptance Easily adjust radon level with one knob Includes electronic radon monitor

Precision Trickle Ventilation Technology : 

Precision Trickle Ventilation Technology RadonMan, Inc The Leader in Radon Mitigation Technology in hot, humid climates Solving Radon and Indoor Air Quality Problems since 1986 Expert Witness in Radon, Mold, Moisture, Rot, Odor, Building Science, and Energy Issues www.radonman.net 239 435-0774 wayne@radonman.net