Single-use-USB-Data-Logger

Views:
 
Category: Entertainment
     
 

Presentation Description

Single use temperature data logger is also known as disposable data logger. This data logger can be used to record temperature of sensitive goods such as medicines, food, fruits, vegetables etc.

Comments

Presentation Transcript

slide 1:

Rev 1 12 Jan 2015 Please input your required data in the highlighted cells Details Example Description Customer name: Please give your details for reference Your Time Zone GMT+4 Please indicate your time Zone where the data will be recorded Day time savings Yes/No Yes Please indicate Yes if your time zone has day time savings Readings in Deg C or Deg F Deg C Please indicate whether you want to be in Deg C or Deg F Sampling interval seconds 60.00 Seconds The frequency can be programmed from 5 seconds to 17 hours. eg. If sampling interval is programmed to be 60 seconds the temperature reading will be recorded every 60 seconds This also will decide the total duration of recording. The logger has a memory capacity to record 7928 readings. Hence if sampling interval is 60 seconds it will record for 5.5 days If sampling interval is every 3 minutes it will record for 16.5 days If sampling interval is every 5 minutes it will record for 27.5 days Start Delay minutes 10.00 Minutes This decides the delay to start recording after pressing the start button. Eg. If delay is 10 minutes the logger will start recording 10 minutes after starting the logger eg. If you are planning to keep the logger inside a 2-8 Deg box it is better to keep 10 minutes delay. Other wise when the logger is started outside the box the first few readings may be recorded in the room temperature. High High Alarm 10 ° C 3 minutes The second red LED will be activated once the temperature goes above this temperature for the delay period. LED will start blinking if temperature goes above 10°C for 3 minutes High Alarm 8 ° C 3 minutes The first red LED will be activated once the temperature goes above this temperature for the delay period Low Alarm 2 ° C 3 minutes The first Blue LED will be activated once the temperature goes below this temperature for the delay period Low Low Alarm 0 ° C 3 minutes The second Blue LED will be activated once the temperature goes below this temperature for the delay period Total delay before alarm 5 Input any value between 1 and 254. If you enter 5 the alarm LED will not be triggered unless 5 readings are recorded above the alarm level for 5 times. 5 times during the entire duration not necessarily to be consecutive Consecutive delay before alarm 4 Input any value between 1 and 254. If you enter 4 the alarm LED will not be triggered unless 4 consecutive readings are recorded above the alarm level for 4 times. If you want to program the device yourself please check the link: Details of SIngle use Disposable Data Logger Your Input Programming details for Single use USB Data Logger Models MS-ST-S-8 MS-ST-S-8-P VackerGlobal 306 RKM Bldg DeiraDubai United Arab Emirates www.vackerglobal.com Email: infovackerglobal.com Tel:+971 42 66 11 44

authorStream Live Help