CONDITION MONITORING IN THERMAL POWER PLANT

Views:
 
     
 

Presentation Description

No description available.

Comments

By: kishoreputha (12 month(s) ago)

hi sir i want this presentation it is very interesting ....... please allow me to download this presentation

By: mostafa_mobset (12 month(s) ago)

Thank you

By: webstarsandeep (13 month(s) ago)

Dear Sir, Currently we are working for tube cleaning analysis project for our academics. Kindly send me this ppt and any other available related to tube maintenance to webstarsandeep@gmail.com Thanks & Regards, Sandeep

By: nganmh (15 month(s) ago)

e -mail address : nganmh@hotmail.com

By: nganmh (15 month(s) ago)

It is very related to my job, would you please send me the presentation of condition monitorin in thermal power plant for my further learning? Thank you

See all

Presentation Transcript

CONDITION MONITORING IN THERMAL POWER PLANT : 

CONDITION MONITORING IN THERMAL POWER PLANT SHIVAJI CHOUDHURY

OBJECTIVE OF CONDITION MONITORING : 

OBJECTIVE OF CONDITION MONITORING TO IDENTIFY CHANGES IN CONDITION OF MACHINE THAT WILL INDICATE SOME POTENTIAL FAILURE. DIAGNOSIS OF FAULT PREDICTION OF FAULT TO AVOID FURTHER DAMAGES TO PLAN BETTER SPARE MANAGEMENT OUTAGE OF EQUIPMENT CAN BE BETTER PLANNED. ENHANCING THE MACHINE EDURANCE LIMIT. LESS DOWN TIME AND MORE PRODUCTIVITY GREATER SAFETY TO WORK FORCE.

MONITORING TECHNIQUE : 

MONITORING TECHNIQUE VIBRATION MONITORING. LUBRICANT ANALYSIS. NOISE ANALYSIS. WEAR DEBRIS ANALYSIS. THERMOGRAGHY. D G A. NDT ULTRASONIC

VIBRATION ANALYSIS : 

VIBRATION ANALYSIS TURBINE. GENERATOR. PUMP. MOTOR. FAN. COMPRESSOR.

VIBRATION DIAGNOSIS : 

VIBRATION DIAGNOSIS SHAFT AND ROTOR- UNBALANCE , BENT, MISALIGNMENTS BEARING –DAMAGES,,DISTORTION,LOSS OF LUBRICANT. GEAR –TOOTH MESHING FAULT,WORN TEETH,MISALIGNMENT MECHANICAL LOOSNESS

LUB OIL ANALYSIS : 

LUB OIL ANALYSIS MOISTURE MECHANICAL IMPURIRTIES DENSITY VISCOCITY ACIDITY

LUB OIL DIAGNOSIS : 

LUB OIL DIAGNOSIS DEGRADATION OF LUB OIL IMPURITIES IN LUB OIL

WEAR DEBRIS ANALYSIS & DIAGNOSIS : 

WEAR DEBRIS ANALYSIS & DIAGNOSIS WEAR DEBRIS CARRIED OUT FOR WEAR PARTICLE CONCENTRATION IN OIL CONDITION OF LUB OIL OUTSIDE CONTENMATION TO DETERMINE TO WEAR CONDITION OF MACHINE NORMAL RUBBING BEARING FAILURE CONDITION OF GEAR CUTTING OF METAL

THERMOVISION MONITORING : 

THERMOVISION MONITORING IDENTIFICATION OF HOT SPOT . USED FOR MONITORING OF SWITCHYARD EQUIPMENT. ROUTINE MONITORING OF MOTOR/PUMP. MONITORING OF DRAIN PIPES LINES TO DETECT CHOKING OF PIPE LINES. TO MONITOR OF CONDITION OF INSULATION ON PIPE AND EQUIPMENT.

DISSOLVE GAS ANALYSIS : 

DISSOLVE GAS ANALYSIS FOR ALL TRANSFORMERS. DIELECTRIC STRENGTH OF TRANSFORMER OIL. MOISTURE,DENSITY,COLOUR OF TRANSFORMER OIL. DISSOLVE GAS ANALYSIS IN TRANSFORMER OIL-TO DIAGNOSIS OF FAULT.

TRANSFORMER OIL DIAGNOSIS : 

TRANSFORMER OIL DIAGNOSIS CO AND CO2 IN OIL—THERMALCONDITION INVOLVING PAPER METHANE,ETHANE,ETHYLENE AND SMALL AMOUNT OF ACETYLENE IN OIL - THERMAL CONDITION INVOLVING THE OIL HYDROGEN,METHA AND SMALL AMOUNT OF ACETYLENE AND ETHANE IN OIL--PARTIAL DISCHARGE HYDROGEN,ACETYIENE AND ETHELENE IN OIL-SUSTAINED ARCING-SUSTAINED ARCING

CONDITION MONITORING SCHEDULE : 

CONDITION MONITORING SCHEDULE VIBRATION MONITORING DAILY/WEEKLY/MONTHLY CHEMICAL ANALYSIS OF OIL QUARTELY THERMOGRAPHY QUARTELY DGA QUARTELY NSD ULTRASONIC ANNUALY

THANKYOU : 