LED Heatsinks & Housings Tips from Top T8 LED Tube Manufacturer China

Views:
 
     
 

Presentation Description

T8 LED Tubes with Heat Sink - Buyer Guide China

Comments

Presentation Transcript

slide 1:

R LED T8 Tube with Aluminium Heat Sink DLC 4.0 E484385 E484385 Lighting Specialists in High Efficiency Lighting

slide 2:

Specialists in High Efficiency Lighting www.seniorled.com PolycarbonatePC Tube with Internal Aluminium Heat Sink Transparent or frosted fully polycarbonate tube cover for increased light transmission and protection from electrical shock. Perfect for USA where internal isolators are not required by law. PLUS internal aluminium heat sink for improved heat dissipation and extended lifespan. 270° beam angle for improved light coverage -widest available on the market in 2016 Perfect combination of safety and durability. Light weight and impact resistant for peace of mind during transport and installation. High Luminous Efficiency 150-165lm/W with CSA Test Report Low level factories believe increasing the efficiency of LED chips is the only way to increase the lights lumens. We create cost-effective 10 high lumen lighting by controlling four aspects: 1.The efficiency of driver must be over 92. 2.Light transmittance diffusion of diffuse cover must be over 93. 3.Maximize every single LED chips output. 4.Design the arrangement of IF and VF of LED chips perfectly. Super Driver We use Japanese RUBYCON IC and special thickness PCB board for our own perfectly designed driver producing reliable drivers with a long lifespan. • Full protection function against short circuiting current overload voltage overload and protection against surges. Wide input voltage range. 100-277V. Maximum industrial input voltage can be customized to 305V if required Electrolytic capacitor information: DC36-80V 240MA Long lifespan design.105°C 35000-50000 working hours THD 15 AIG Insured All of our LED lighting products are insured with AIG Product Liability Insurance. It ensures peace of mind in the rare event of any manufacturing faults or defects by guaranteeing our warranty and compensation. 2 R PolycarbonatePC with Internal Aluminium Heat Sink Aluminium heat sink SMLED Chips Polycarbonate PC tube

slide 3:

www.seniorled.com Features Single end power supply ballast bypass gives added anti-electric shock measures ensuring safety. Internal constant current driver features a instant start up or shut off mechanism with no warming up times and flickering as well as protection from overpowering overheating electrical shorting and overexposed circuitry. Wide input voltage range 120-277V/AC and THD 15. Retrofit for direct replacement of T8 linear fluorescent compatible with G13 socket R17D FA8 available. Environmentally friendly and mercury free – eliminating hazardous installation removal and disposal. Certified by UL cUL and DLC 4.0 listed. Long lifespan up to 50000hrs. Based on ideal temperature 25°C and 10hrs/day operating conditions. Limited warranty 5 years insured by AIG. Office Supermarket Hotel Exhibition hall COMMERCIAL LIGHTING PUBLIC LIGHTING INDUSTRIAL LIGHTING Tunnel MTR station Etc Train station Bus station Airport Factory Warehouse Applications 3 R Specialists in High Efficiency Lighting

slide 4:

Certificates UL cUL DLC Ballast Compatible NoSingle end power supply Lamp Body Material PC+Aluminium Heat Sink Lamp Cover Available Frosted Clear 3000K 4000K 5000K 6500K without DLC Color Temperature Epistar/Hongli LED Chips Brand CRI Ra ≥80 Dimmable No THD 15 Life Span 50000 + hours Warranty 5 Years www.seniorled.com 4 Power Factor ≥0.95 Beam Angle ° 160° LED Type SMD 2835 Header G13 LED Chips Qty pcs 126 Real Power W 12±1 Clear Lens 1850 luminous flux lm 150Lm/w Frost Lens 1800 Carton Size mm 1305193240 Dimension LWD 1200/26/30mm Qty per CTN pcs 30 Model SLPV-4FT-12W Input V Electric Spec 100277 Specification R Specialists in High Efficiency Lighting

slide 5:

www.seniorled.com 54200 Pcs per 40HQ 1200MM T8 Length TUBE Type 1 Single Box 40 Pcs/ctn 12.8 G.W./ctnkg 22360 Pcs per 20GP Finished product pile up Packing A C Product Dimension B Model NO. Size AMM Size BMM Size CMM SLPV-4FT-12W 1200 26 12.7 G13 5 R Above loading quantity is calculated without pallet. Specialists in High Efficiency Lighting

slide 6:

www.seniorled.com Installation Guide BEFORE YOU BEGIN Read these instructions completely and carefully. Provided Components The components have been properly packed to avoid damage during transit. Inspect the components to confirm there is no physical damage. Do not install damaged components. The carton consists of: LED tubes Drivers Instruction sheet Labels Tools and Components Required Screwdriver 6-12mm Wire cutters WARNING RISK OF FIRE OR ELECTRIC SHOCK • Disconnect power before installation or maintenance. Contact a qualified electrician for installation. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified do not attempt installation. Contact a qualified electrician. • • Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. • To prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or other sharp objects. Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors. CAUTION RISK OF INJURY • Tube may fall down if not installed properly follow installation instructions. • Wear safety glasses and proper aid during installation and maintenance. RISK OF PRODUCT DAMAGE • Do not replace conventional LFL directly with LED tubes. Save These Instructions These Instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to be met in connection with installation operation or maintenance. Should further information be desired or should particular problem arise which are not covered sufficiently for the purchaser’s purpose the matter should be referred to Seniorled Ltd. Seniorled does not claim liability for any installation not performed according to this guide or not by a qualified electrician. Installation to be performed by factory trained or qualified personnel. Ensure this manual is provided to the installers and users. Use this product only in the manner intended by the manufacturer. If there are any questions or concerns contact the manufacturer. This tube is designed for indoor application only and should not be used in environment of high temperature and high humidity. This device is not intended for use with Emergency exits. Suitable for dry location. Max. 4pcs LED tubes can be operated in a luminaire. For Your Safety Read and observe all CAUTIONS and WARNINGS shown throughout these instructions. Refit Solutions 6 R Specialists in High Efficiency Lighting

slide 7:

www.seniorled.com Inspire-led Tube Retrofit 7 Fluorescent Tube Fluorescent Tube Remove ballast reconnect the wire Remove ballast reconnect the wire Packaging It is important to inspect and replace the socket/tube holder or remove the brass tab in the socket/tube holder that may join the Live and natural wires causing a short circuit. The socket/tube holder must separate the live wire connection from the natural wire. If the ballast contains PCB please remove and dispose of them safely. They are extremely toxic and hazardous to people and the environment. Take out the ballast and starter if found disconnect the wires and either leave the ballast in place or remove it. After disconnecting the ballast reconnect the circuit. There are two sets of wires that connect to each bulb - only one set is needed to be connected to the respective Live and natural wires. Refer to the wiring diagram. If you have a fixture with more than one tube holder double or quads make sure only one wire set from each additional fixture is going to the Live and natural supply wires. Disconnect any jumper wires connecting the additional fixtures to each other. In effect on a single tube there should be four wires two at each end going to the the live and natural supply wires. Now you only need one going to the live and natural supply wires from each fixture. Refer to the wiring diagram. Install the new LED Tube into the fluorescent light fixture. Inspect all wiring connections prior to turning on the power. Switch on the power to light the LED tube. Installation steps retrofit existing fixture with ballast Installation based on Magnetic Ballast Installation based on Electronic Ballast Senior Led Tube Senior Led Tube Retrofit AC100-277V AC100-277V Remove the starter reconnect the wire. Remove ballast reconnect the wire. Remove ballast reconnect the wire. Electronic Ballast Electronic Ballast No Electrical Connections. Used only for fixture support. No Electrical Connections. Used only for fixture support. R Specialists in High Efficiency Lighting

slide 8:

www.seniorled.com New Installation – fixture without ballast There are two sets of wires that connect to each bulb –only one set is needed to be connected to the respective Live and natural wires. If you have a fixture with more than one tube holder double or quads make sure that only one wire set from each additional fixture is going to the Live and cold supply wires. Disconnect any jumper wire connecting the additional fixtures to each other. In effect on a single tube there were four wires two at each end going to the Live and natural supply wires. Now you only need one going to the Live and natural from each fixture. Install the new Internal Driver LED tube into the fluorescent light fixture. Inspect all wiring connections prior to turning on the power. Switch on the power to light the LED tube. 8 AC100-277V Switch No Electrical Connections. Used only for fixture support. R Specialists in High Efficiency Lighting

authorStream Live Help