PPT ON TRANSFORMER

Views:
 
Category: Education
     
 

Presentation Description

IN THIS PRESENTATION TOTAL KNOWLEDGE ALL ABOUT TRANSFORMER DURING SIX MONTHS INDUSTRIAL TRAINING IN MUSKAAN POWER INFRASTRUCTURE LTD.

Comments

Presentation Transcript

PRESENTATION ON SIX MONTHS INDUSTRIAL TRAINING AT MUSKAAN POWER INFRASTRUCTURE LTD. Presented By:- PUSHKAR KUMAR ROLL NO.- 90210718918 B.TECH-EEE , 8TH SEM.  :

PRESENTATION ON SIX MONTHS INDUSTRIAL TRAINING AT MUSKAAN POWER INFRASTRUCTURE LTD. Presented By:- PUSHKAR KUMAR ROLL NO.- 90210718918 B.TECH-EEE , 8 TH SEM .

COMPANY PROFILE:

COMPANY PROFILE Muskaan Power Infrastructure Ltd. (Formerly Known as Muskaan Engineers) Year of Establishment : 2003 Nature of Business : Supplier, Manufacturer, Exporter Total Number of Employees : 101 to 500 People Turn over : 65 crores

INTRODUCTION OF TRANSFORMER:

INTRODUCTION OF TRANSFORMER A Transformer is a static device which transfers ac electrical power from one circuit to the other at the same frequency but the voltage level is changed .

PARTS OF TRANSFORMER:

PARTS OF TRANSFORMER Main tank Primary winding Secondary winding Buchholz relay Oil level indicator Breather Radiator L T & HT bushes Tap changer Air release plug

PROCESS FLOW CHART:

PROCESS FLOW CHART

WINDING SECTION L.V WINDING :

WINDING SECTION L.V WINDING

PowerPoint Presentation:

15 KVA L.V WINDING DETAILS I.D 84mm O.D 96mm A/L 366 mm Turn 75 Turn/layer 37 Layer 2 Conductor Size 9.0 x 2.0

H.V WINDING:

H.V WINDING

PowerPoint Presentation:

Number of layer 18 Number of turn 1888 I .D 166 mm O.D 141 mm A/L 68 mm Number of turn /layer 108 Size of wire 050 i.e , 25 no. wire . Tapping type 1167-1525 15 KVA H.V WINDING DETAILS Note :- I.D- Inner diameter. O.D-Outer diameter. A/L-Axial length

CORE SECTION:

CORE SECTION

PowerPoint Presentation:

A1 140 68.8 A2 130 17.4 A3 120 13.5 A4 110 10.9 A5 100 9.1 A6 85 11.1 A7 70 8.6 A8 55 6.6 A9 40 4.8 225 KVA CORE SPECIFICATION DETAILS CD-156 L ayer W idth (mm) Height(mm) CL-260 WH-400 Base on which core is placed is called CHANNEL . Core cutting by Press machine

PLACEMENT OF LV WINDING :

PLACEMENT OF LV WINDING The core is covered with cotton and this coil winding in the core limb. They are fitted tightly in all three limb using pressed board.

PLACEMENT OF HV WINDING:

PLACEMENT OF HV WINDING This coil is placed on LV winding as second layer of core. -LV coil then after HV coil. - the gap b/w the LV and HV coil is filled with runner of pressed board using cotton.

PowerPoint Presentation:

TRANSFORMER TANK

PowerPoint Presentation:

CLEANING OF TRANSFORMER TANK: When the cabinet of transformer is prepared. Dip in acid at least 15 min. during summer season or otherwise 2 hours. In order to remove paints & rust. Put in water to clean-up. Again put in acid to bring roughness on tank to have proper grip. ACID  WATER  ACID  PRIMER  PAINT

INSULATION:

INSULATION 1.Transformers Insulated with NOMEX brand materials are extremely safe , even when exposed to fire . 2.Pre-compressed board PARMALI board and JAPANEESE insulation paper of best quality is used. 3. Insulation is friendly to use during manufacturing , no skin irritants .

FUNCTION OF TRANSFORMER OIL:

FUNCTION OF TRANSFORMER OIL Muskaan Transformers are designed for a maximum temp. rise of 40-50 o C of oil and winding. Oil is tested for resistivity, dielectric and acidic characteristics. The transformer is immersed in oil which acts as an insulator as well as a coolant .

CONNECTIONS:

CONNECTIONS STAR –STAR DELTA – DELTA STAR – DELTA DELTA – STAR Relations :- In Star I L = I ph & V L = √3 V ph In Delta V L = V ph & I L = √3I ph

TESTING OF TRANSFORMER:

TESTING OF TRANSFORMER All transformers are tested for Routine test Routine tests :- Measurement of winding resistance . Measurement of voltage / turn ratio. Measurement of impedance voltage / short circuit . Measurement of No load loss & No load current . Measurement of Insulation resistance . Ratio test between three phases .

LOSSES IN TRANSFORMER:

LOSSES IN TRANSFORMER LOSSES : - 1. COPPER LOSS ( variable loss ) 2. IRON LOSS a.) Hysteresis loss b.) Eddy current loss Magneto striation :- Types of losses in a transformer . i.e. , Humming noise of transformer.

FAULTS IN TRANSFORMER:

FAULTS IN TRANSFORMER Temperature rise in winding . Temperature rise in oil. Overload Insulation failure in oil. Short circuit Failure of Tap- changing Open circuit Over heating etc.

PROTECTION OF TRANSFORMERS:

PROTECTION OF TRANSFORMERS Oil Temperature Indicators. Winding Temperature indicators. Buchholz Relay. Oil level Gauge. Explosion Vent.

APPLICATION AREAS:

APPLICATION AREAS Cement Plant High Rise Buildings Cold Storages Tea Estate Tube Mills Flour Mills Nursing Home Engineering Units Rubber Industries Food Processing Units Textile Mills Paper Mills

TRANSFORMER READY FOR DISPATCH :

TRANSFORMER READY FOR DISPATCH

THANK YOU !:

THANK YOU !

THANKS:

THANKS FOR ANY QUERY MY CONTACT NO. 9501476470 & EMAIL:- pushkar918@gmail.com