Streamline E&I design schedules : 

Streamline E&I design schedules Henk Uiterwijk 09-02-2005

Agenda : 

© 2004. Intergraph Corporation. All Rights Reserved. Agenda SmartPlant Instrumentation SmartPlant Electrical Off-Site Projects AsBuilt / Project environment Intergration Benefits Demonstration

What is SmartPlant Instrumentation (SPI)? : 

© 2004. Intergraph Corporation. All Rights Reserved. What is SmartPlant Instrumentation (SPI)? SPI is a instrumentation design and maintenance package. SPI is part of the SmartPlant Enterprise. SPI is a Client – Server application SPI is used world-wide by leading Operating Owners

SPI Product Highlights : 

© 2004. Intergraph Corporation. All Rights Reserved. SPI Product Highlights Supporting Oracle and MS SQL Server Import/Export data to/from almost any source Project Environment Generate documents on-the-fly Revision management Part of SmartPlant Enterprise Use of 3rd party suppliers data Demo Demo

What is SmartPlant Electrical? : 

© 2004. Intergraph Corporation. All Rights Reserved. What is SmartPlant Electrical? An easy and flexible tool for electrical engineers to design and maintain electrical power distribution networks.

What is SmartPlant Electrical? : 

© 2004. Intergraph Corporation. All Rights Reserved. What is SmartPlant Electrical? Creation of consistent data, using reference data, and conventions. No drawing tool but it creates the main electrical documents from the database. Organizing plant / project power consumption and spare capacity. Adding automation and efficiency: Create data once, use it many times. Data centric engineering tool

Share data between SPI and SPEL : 

© 2004. Intergraph Corporation. All Rights Reserved. Share data between SPI and SPEL Tag Number Power Supply Wiring Data Loop Data Panel Data

Slide 8: 

© 2004. Intergraph Corporation. All Rights Reserved. Ability to view and embed SPI loop drawings in SPEL schematics (and vice versa, ability to view schematics in SPI) Retrieve of PLC card termination data into Schematics

© 2004. Intergraph Corporation. All Rights Reserved.

Slide 10: 

© 2004. Intergraph Corporation. All Rights Reserved.

Slide 11: 

© 2004. Intergraph Corporation. All Rights Reserved.

Slide 12: 

© 2004. Intergraph Corporation. All Rights Reserved.

Slide 13: 

© 2004. Intergraph Corporation. All Rights Reserved.

Slide 14: 

© 2004. Intergraph Corporation. All Rights Reserved.

Slide 15: 

© 2004. Intergraph Corporation. All Rights Reserved.

Centralize Databases (Off-Site) : 

© 2004. Intergraph Corporation. All Rights Reserved. Centralize Databases (Off-Site) Local Engineering Department EPC 1 Project B Country X EPC 1 Project A Country X EPC 2 Project A Country Y

Centralized Database (Off-Site) : 

© 2004. Intergraph Corporation. All Rights Reserved. Centralized Database (Off-Site) Minimize ‘on-site’ employees No confusion with As-Built data Consistent Data Entry No Data Hand-over Shorter engineering times Re-use AsBuilt data in a Project. From Project to Asbuilt < 1 Day

AsBuilt / Project Environment : 

© 2004. Intergraph Corporation. All Rights Reserved. AsBuilt / Project Environment AsBuilt Site Project A Project B Claimed data

Benefits Project Environment : 

© 2004. Intergraph Corporation. All Rights Reserved. Benefits Project Environment Check work progress All parties using same reference data Correct non-compliancy in early stage No data hand-over No document hand-over Shorter project times

Why a DCS Interface? – Benefits : 

© 2004. Intergraph Corporation. All Rights Reserved. Why a DCS Interface? – Benefits Improve engineering performance Reuse of intellectual investment Reduce risks throughout the entire plant life cycle Improved decision support Automatic generation of project documentation Single source of information throughout the entire plant life cycle SPI providing Validation Rules preventing design mistakes, such as: incorrect terminal layout including terminal numbering incorrect channel type for every terminal Control on naming of different parts to the DCS configuration (e.g. panel name, nest / rack name, etc.) Control over other parameters of the card configuration

When a DCS Interface? : 

© 2004. Intergraph Corporation. All Rights Reserved. When a DCS Interface? New Greenfield Projects Exiting Brownfield: Plant Expansion Plant Revamp / Modification DCS Upgrade Plant Upgrade to Foundation FieldBus Process Design Changes Information As-building Production Changes and Simulation Re-runs Etc, Etc,

Slide 22: 

© 2004. Intergraph Corporation. All Rights Reserved. DCS Current Vendor Alliance status Single Direction Interface (SPI >> DeltaV) available since V6.0 Bi-Directional I/F (SPI – DeltaV) dev starting on SPF Adaptors soon... Successfully proto-types of AMS – SPI interface using SPI - API Bi-Directional I/F (SPI – CS3000) available since V7.0 Continue improve the interface with tight cooperation with Yokogawa Bi-Directional I/F (SPI – System 800xA) available (V6.0 / V7.0) = PETI ABB Catalog Manager available from V7.0.2 Note - PETI sold only by ABB Honeywell standardized on SPI for Global projects EPKS Catalog Manager available from V7.0.2 Bidirectional Interface in SPI V8

Slide 23: 

© 2004. Intergraph Corporation. All Rights Reserved. Engineering SP Instrumentation DeltaV Resources Configured Control System DeltaV Reconcile File DeltaV System DeltaV Components SPI The Interface

Slide 24: 

© 2004. Intergraph Corporation. All Rights Reserved. The CS 3000 Interface

ROI Sample (1) : 