logging in or signing up OB-dopplerultrasound hamoda1992 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 50 Category: Education License: Some Rights Reserved Like it (0) Dislike it (0) Added: December 18, 2009 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript DOPPLER ULTRASOUND in Pregnancy : DOPPLER ULTRASOUND in Pregnancy Dr. Mohammed AbdallaEgypt, Domiat Hospital Doppler History : First use of Doppler ultrasonography to study flow velocity in the fetal umbilical artery was reported in 1977 Doppler History Doppler History : Doppler History Fitzgerald & Drumm. Umbilical artery studies 1977BMJ Eik-Nes et al. Fetal aortic velocimetry : Dupplexscanner 1980 Lancet Campbell et al. Utero-placental circulation: Dupplex scanner 1983 Lancet Wladimiroff et al. MCA / UA PI ratio 1987 OG Kiserud et al. Ductus venosus velocimetry 1991Lancet Basic principals : Basic principals Echoes from stationary tissues are the same from pulse to pulse. Echoes from moving objects exhibit slight differences in the time for the signal to be returned to the receiver. These differences can measured as phase shift from which the Doppler frequency is obtained. . Slide 5: T1 : time of omitted signal . T2 : time of returned signal . T2 – T1 = time difference or phase shift . from phase shift the Doppler frequency is obtained. AS TIME DIFFERENCE DECREASE THE DOPPLER FREQUENCY INCREASE. Slide 6: pulse repetition frequency (T2 –T1) phase shift with known beam / flow angle can calculate flow velocity . T1 T2 Basic Principals : The time difference or phase shift are then proceeded to produce either colorflow display or a Doppler sonogram Basic Principals Basic Principals : Basic Principals ‘Doppler frequency’ is obtained by measuring the time difference for the signal to be returned when reflected from moving scatterers . Doppler frequency increase if: flow velocity increased . beam is more aligned to the direction of flow. higher transducer frequency is used. Slide 9: (the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. Freq. q The angle of insonation Flow velocity 3 2 1 Factors affecting doppler frequency (the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. : (the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. beam (A) is more aligned than (B) The beam/flow angle at (C) is almost 90° and there is a very poor Doppler signal The flow at (D) is away from the beam and there is a negative signal. Aliasing : Aliasing If a second pulse is sent before the first is received, the receiver cannot discriminate between the reflected signal from both pulses and aliasing occur. Aliasing : So to eliminate aliasing The pulse repetition frequency or scale is set appropriately for the flow velocities Aliasing Slide 13: The volume flow in the UAs increases with advancing gestation. The high vascular impedance detected in the first trimester gradually decreases. It is attributed to growth of placental unit and increase in the number of the functioning vascular channels. Basic Principals Uses : Uses plays a vital role in the diagnosis of fetal cardiac defects . assessment of the hemodynamic responses to fetal hypoxia and anemia. diagnosis of other non-cardiac malformations. Slide 15: Blood supply provided by the ovarian and uterine arteries Uterine Arteries: main branches of the internal iliac arteries Uterine Arteries: Ascend through the lateral wall and anastomose with the ovarian arteries Anatomy Slide 16: Spiral Arteries: connect the maternal circulation to the endometrium Responsible for a 10 fold increase in blood flow Anatomy Arcuate Arteries: Run Circumferentially around the uterus Uterus: Blood supply to anterior and posterior walls provided by the Arcuate arteries Radial Arteries: Extend from the arcuate arteries and enter the endometrium Slide 17: Conversion of small muscular spiral arteries into large vascular channels transforms the uteroplacental circulation into a low-resistance-to-flow system. These have a dilated and tortuous lumen, a complete absence of muscular and elastic tissue, no continuous endothelial lining. Anatomy Slide 18: Umbilical artery doppler Slide 19: Doppler indices Slide 20: UMBILICAL ARTERY FLOW characteristic saw-tooth appearance of arterial flow in one direction and continuous umbilical venous blood flow in the other. Umbilical artery FACTORS AFFECTING UMBILICAL ARTERY DOPPLER FLOW VELOCITY WAVEFORMS* : FACTORS AFFECTING UMBILICAL ARTERY DOPPLER FLOW VELOCITY WAVEFORMS* Slide 22: Benefit of Umbilical Artery Evaluation Less experienced operators can achieve highly reproducible results with simple, inexpensive continuous-wave equipment . Umbilical artery Slide 23: The 40% of the combined fetal ventricular output is directed to the placenta by two umbilical arteries. The assessment of umbilical blood flow provides information on blood perfusion of the fetoplacental unit . . Umbilical artery Slide 24: With advancing gestation, umbilical arterial Doppler waveforms demonstrate a progressive rise in the end-diastolic velocity and a decrease in the pulsatility index. Umbilical artery Slide 25: Middle cerebral artery doppler The possible Doppler velocimetry sites : Using color flow imaging, the middle cerebral artery can be seen as a major lateral branch of the circle of Willis, running anterolaterally at the borderline between the anterior and the middle cerebral fossae The possible Doppler velocimetry sites Middle cerebral artery Middle cerebral artery : Middle cerebral artery The blood velocity increases with advancing gestation, and this increase is significantly associated with the decrease in PI Middle cerebral artery : An early stage in fetal adaptation to hypoxemia - central redistribution of blood flow ( brain-sparing reflex) increased blood flow to protect the brain, heart, and adrenals reduced flow to the peripheral and placental circulations Middle cerebral artery Doppler wave form of early stage of fetal hypoxemia : Doppler wave form of early stage of fetal hypoxemia increased end-diastolic flow in the middle cerebral artery (lower MCA pulsatility index or resistance index) Average of both MCAs must be calculated for more precise result Middle Cerebral Artery : Middle Cerebral Artery Flow velocity waveform in the fetal middle cerebral artery in a severely anemic fetus at 22 weeks (left) and in a normal fetus (right). In fetal anemia, blood velocity is increased Middle Cerebral Artery : When the fetus is hypoxic, the cerebra arteries tend to become dilated in order to preserve the blood flow to the brain and The systolic to diastolic (A/B) ratio will decrease (due to an increase in diastolic flow) Middle Cerebral Artery Doppler ultrasound for the fetal assessment in high-risk pregnancies (Cochrane Review). In: The Cochrane Library, 1999. Neilson JP and Alfirevic Z : Doppler ultrasound for the fetal assessment in high-risk pregnancies (Cochrane Review). In: The Cochrane Library, 1999. Neilson JP and Alfirevic Z Trudinger et al 1987 McParland et al 1988 Tyrrell et al 1990 Hofmeyr et al 1991 Newham et al 1991 Burke et al 1992 11 Studies Included In Analysis Almstrom et al 1992 Biljan et al 1992 Johnstone et al 1993 Pattison et al 1994 Nienhuis et al 1997 Doppler ultrasound for the fetal assessment in high-risk pregnancies : Doppler ultrasound for the fetal assessment in high-risk pregnancies Nearly 7000 patients were included The trials compared no Doppler ultrasound to Doppler ultrasound in high-risk pregnancy (hypertension or presumed impaired fetal growth) Meta analysis Doppler ultrasound for the fetal assessment in high-risk pregnancies : Doppler ultrasound for the fetal assessment in high-risk pregnancies A reduction in perinatal deaths. Fewer inductions of labour . Fewer admissions to hospital . no report of adverse effects . No difference was found for fetal distress in labour . No difference in caesarean delivery . Main results Biophysical profile for fetal assessment inhigh risk pregnancies : Biophysical profile for fetal assessment inhigh risk pregnancies • When compared with conventional fetal monitoring (usually cardiotocography) biophysical profile testing showed no obvious effect (either beneficial or deleterious) on pregnancy outcome. There was an increase in the number of inductions of labour following biophysical profile in the trial. Alfirevic Z, Neilson JP. Biophysical profile for fetal assessment in high risk pregnancies (CochraneReview). In: The Cochrane Library, 1995. Slide 36: Thank you You do not have the permission to view this presentation. In order to view it, please contact the author of the presentation.
OB-dopplerultrasound hamoda1992 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 50 Category: Education License: Some Rights Reserved Like it (0) Dislike it (0) Added: December 18, 2009 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript DOPPLER ULTRASOUND in Pregnancy : DOPPLER ULTRASOUND in Pregnancy Dr. Mohammed AbdallaEgypt, Domiat Hospital Doppler History : First use of Doppler ultrasonography to study flow velocity in the fetal umbilical artery was reported in 1977 Doppler History Doppler History : Doppler History Fitzgerald & Drumm. Umbilical artery studies 1977BMJ Eik-Nes et al. Fetal aortic velocimetry : Dupplexscanner 1980 Lancet Campbell et al. Utero-placental circulation: Dupplex scanner 1983 Lancet Wladimiroff et al. MCA / UA PI ratio 1987 OG Kiserud et al. Ductus venosus velocimetry 1991Lancet Basic principals : Basic principals Echoes from stationary tissues are the same from pulse to pulse. Echoes from moving objects exhibit slight differences in the time for the signal to be returned to the receiver. These differences can measured as phase shift from which the Doppler frequency is obtained. . Slide 5: T1 : time of omitted signal . T2 : time of returned signal . T2 – T1 = time difference or phase shift . from phase shift the Doppler frequency is obtained. AS TIME DIFFERENCE DECREASE THE DOPPLER FREQUENCY INCREASE. Slide 6: pulse repetition frequency (T2 –T1) phase shift with known beam / flow angle can calculate flow velocity . T1 T2 Basic Principals : The time difference or phase shift are then proceeded to produce either colorflow display or a Doppler sonogram Basic Principals Basic Principals : Basic Principals ‘Doppler frequency’ is obtained by measuring the time difference for the signal to be returned when reflected from moving scatterers . Doppler frequency increase if: flow velocity increased . beam is more aligned to the direction of flow. higher transducer frequency is used. Slide 9: (the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. Freq. q The angle of insonation Flow velocity 3 2 1 Factors affecting doppler frequency (the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. : (the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. beam (A) is more aligned than (B) The beam/flow angle at (C) is almost 90° and there is a very poor Doppler signal The flow at (D) is away from the beam and there is a negative signal. Aliasing : Aliasing If a second pulse is sent before the first is received, the receiver cannot discriminate between the reflected signal from both pulses and aliasing occur. Aliasing : So to eliminate aliasing The pulse repetition frequency or scale is set appropriately for the flow velocities Aliasing Slide 13: The volume flow in the UAs increases with advancing gestation. The high vascular impedance detected in the first trimester gradually decreases. It is attributed to growth of placental unit and increase in the number of the functioning vascular channels. Basic Principals Uses : Uses plays a vital role in the diagnosis of fetal cardiac defects . assessment of the hemodynamic responses to fetal hypoxia and anemia. diagnosis of other non-cardiac malformations. Slide 15: Blood supply provided by the ovarian and uterine arteries Uterine Arteries: main branches of the internal iliac arteries Uterine Arteries: Ascend through the lateral wall and anastomose with the ovarian arteries Anatomy Slide 16: Spiral Arteries: connect the maternal circulation to the endometrium Responsible for a 10 fold increase in blood flow Anatomy Arcuate Arteries: Run Circumferentially around the uterus Uterus: Blood supply to anterior and posterior walls provided by the Arcuate arteries Radial Arteries: Extend from the arcuate arteries and enter the endometrium Slide 17: Conversion of small muscular spiral arteries into large vascular channels transforms the uteroplacental circulation into a low-resistance-to-flow system. These have a dilated and tortuous lumen, a complete absence of muscular and elastic tissue, no continuous endothelial lining. Anatomy Slide 18: Umbilical artery doppler Slide 19: Doppler indices Slide 20: UMBILICAL ARTERY FLOW characteristic saw-tooth appearance of arterial flow in one direction and continuous umbilical venous blood flow in the other. Umbilical artery FACTORS AFFECTING UMBILICAL ARTERY DOPPLER FLOW VELOCITY WAVEFORMS* : FACTORS AFFECTING UMBILICAL ARTERY DOPPLER FLOW VELOCITY WAVEFORMS* Slide 22: Benefit of Umbilical Artery Evaluation Less experienced operators can achieve highly reproducible results with simple, inexpensive continuous-wave equipment . Umbilical artery Slide 23: The 40% of the combined fetal ventricular output is directed to the placenta by two umbilical arteries. The assessment of umbilical blood flow provides information on blood perfusion of the fetoplacental unit . . Umbilical artery Slide 24: With advancing gestation, umbilical arterial Doppler waveforms demonstrate a progressive rise in the end-diastolic velocity and a decrease in the pulsatility index. Umbilical artery Slide 25: Middle cerebral artery doppler The possible Doppler velocimetry sites : Using color flow imaging, the middle cerebral artery can be seen as a major lateral branch of the circle of Willis, running anterolaterally at the borderline between the anterior and the middle cerebral fossae The possible Doppler velocimetry sites Middle cerebral artery Middle cerebral artery : Middle cerebral artery The blood velocity increases with advancing gestation, and this increase is significantly associated with the decrease in PI Middle cerebral artery : An early stage in fetal adaptation to hypoxemia - central redistribution of blood flow ( brain-sparing reflex) increased blood flow to protect the brain, heart, and adrenals reduced flow to the peripheral and placental circulations Middle cerebral artery Doppler wave form of early stage of fetal hypoxemia : Doppler wave form of early stage of fetal hypoxemia increased end-diastolic flow in the middle cerebral artery (lower MCA pulsatility index or resistance index) Average of both MCAs must be calculated for more precise result Middle Cerebral Artery : Middle Cerebral Artery Flow velocity waveform in the fetal middle cerebral artery in a severely anemic fetus at 22 weeks (left) and in a normal fetus (right). In fetal anemia, blood velocity is increased Middle Cerebral Artery : When the fetus is hypoxic, the cerebra arteries tend to become dilated in order to preserve the blood flow to the brain and The systolic to diastolic (A/B) ratio will decrease (due to an increase in diastolic flow) Middle Cerebral Artery Doppler ultrasound for the fetal assessment in high-risk pregnancies (Cochrane Review). In: The Cochrane Library, 1999. Neilson JP and Alfirevic Z : Doppler ultrasound for the fetal assessment in high-risk pregnancies (Cochrane Review). In: The Cochrane Library, 1999. Neilson JP and Alfirevic Z Trudinger et al 1987 McParland et al 1988 Tyrrell et al 1990 Hofmeyr et al 1991 Newham et al 1991 Burke et al 1992 11 Studies Included In Analysis Almstrom et al 1992 Biljan et al 1992 Johnstone et al 1993 Pattison et al 1994 Nienhuis et al 1997 Doppler ultrasound for the fetal assessment in high-risk pregnancies : Doppler ultrasound for the fetal assessment in high-risk pregnancies Nearly 7000 patients were included The trials compared no Doppler ultrasound to Doppler ultrasound in high-risk pregnancy (hypertension or presumed impaired fetal growth) Meta analysis Doppler ultrasound for the fetal assessment in high-risk pregnancies : Doppler ultrasound for the fetal assessment in high-risk pregnancies A reduction in perinatal deaths. Fewer inductions of labour . Fewer admissions to hospital . no report of adverse effects . No difference was found for fetal distress in labour . No difference in caesarean delivery . Main results Biophysical profile for fetal assessment inhigh risk pregnancies : Biophysical profile for fetal assessment inhigh risk pregnancies • When compared with conventional fetal monitoring (usually cardiotocography) biophysical profile testing showed no obvious effect (either beneficial or deleterious) on pregnancy outcome. There was an increase in the number of inductions of labour following biophysical profile in the trial. Alfirevic Z, Neilson JP. Biophysical profile for fetal assessment in high risk pregnancies (CochraneReview). In: The Cochrane Library, 1995. Slide 36: Thank you