ENGLISH INGESCO Presentation 2010

Views:
 
     
 

Presentation Description

LIGHTING Protection System and Devices

Comments

Presentation Transcript

PowerPoint Presentation: 

BEFORE THE WEATHER

INGESCO is…: 

INGESCO is… Prevention & protection against lightning since 1973. Own technology (lightning rods, lightning detectors, develop & manufacture in Terrassa). Lightning phenomena investigation . Projects for a Integral Protection. Accreditation (Entity National of Accreditation) to test lightning rods & to do inspections of the lightning rods installations. Participation in committees for new Standards.

INGESCO GROUP: 

INGESCO GROUP INGESCO INSPECTION ENTITY INSTALLATION ENGINEERING (BIG PROJECTS) LABELEC LABORATORY R + D PRODUCTION SALES EXPORT

RESEARCH + DEVELOPMENT: 

RESEARCH + DEVELOPMENT Investigation in high frequency waves (lightning). Development of new technologies for protection. Collaboration with big centers of public investigation & universities.

RESEARCH + DEVELOPMENT: 

Agreements with meteorological institutes & with groups for Standards: AENOR: Sub-committee AEN/CTN 207/SC 81: Protection against lightning. AENOR: Sub-committee CTN206/SC88: Aero-generators. International experts from AENOR in the group PT 61400-24: Lightning protection for wind turbines Coordination of Groups to work with the Standards: Coordination of the group of AENOR to work in AEN/CTN207/SC81/GT 05 “Storm detectors" Coordination of the group of European work (CENELEC) C;LC/TC 81/WG5 "Thunderstorm detection devices" RESEARCH + DEVELOPMENT

INVESTIGATION: detection: 

INVESTIGATION: detection Measure electromagnetic fields of lightning strikes Measure lightning currents and detection of the strike points .

PowerPoint Presentation: 

Measure of the electrical field and study of the behavior of lightning currents in a earthing system network. INVESTIGATION: IN REAL CONDITIONS Graphic of (electrical field / time) in a storm Current of a lightning strike Voltage in an earthing system network during a lightning current

PowerPoint Presentation: 

INVESTIGATION: IN REAL CONDITIONS Measures of the electromagnetic atmosphere in the sensors of the net of lightning detection. 5th Tower in function in the world in the Pyrenees Mountains .

Laboratory LABELEC: 

Laboratory LABELEC It has a: Generator of impulses of voltage up to 1,0 MV. Generator of impulses of current up to 100kA Laboratory of environmental rehearsals . Credited by for test and rehearsals of lightning rods with Early Streamer Emission device. Generator of voltage impulses up to 1,0 MV.

PowerPoint Presentation: 

Laboratory LABELEC

Laboratory LABELEC: 

Impulse current generator 100 kA wave form (10/350). Laboratory LABELEC

PowerPoint Presentation: 

Test for a connector Test for lightning rods Generator of current impulses up to 100kA wave form (10/350) Rehearsals with connectors according the EN – 50164-1 Standard Laboratory LABELEC

PowerPoint Presentation: 

Rehearsals with current impulse 100 kA wave form (10/350). Rehearsals for connection components according EN–50164-1 Standard Rehearsals for spark gaps according EN–50164-3 Standard Laboratory LABELEC

PowerPoint Presentation: 

Camera of saline fog Bath of chloride of ammonia Laboratory LABELEC Corrosion rehearsals for the connectors according the EN-50164-1 Standard

PowerPoint Presentation: 

Camera of dioxide of sulfur Camera static & humidity Laboratory LABELEC Corrosion rehearsals for the connectors according the EN-50164-1 Standard

PowerPoint Presentation: 

Before the test After the test Laboratory LABELEC Corrosion rehearsals for the connectors according the EN-50164-1 Standard Test for a “T” connector

PowerPoint Presentation: 

Test for lightning counters. Test for TVSS Transient Voltage Surge Suppressors. Laboratory LABELEC Rehearsals with current impulse 35 kA wave form (10/350).

PowerPoint Presentation: 

Eolic investigation and aeronautics: Effects of the lightning in the aero-generators blades and wings of airplanes with carbon fiber. Laboratory LABELEC

PRODUCTION: 

PROTECTION Lightning rod ESE INGESCO © PDC. Lightning rod ESE INGESCO © PDC-E. Lightning rod ESE INGESCO © PDC Stream. PREVENTION Lightning detector IPSO. Location of lightning strikes in a map of 30km radius (in real time). PRODUCTION

PREVENTION: 

PREVENTION Lightning detector IPSO (it detects the magnetic field of the current) Service in SPAIN of Localization, visualization and compute of the lightning strikes in a radius of 30km (in real time).

PowerPoint Presentation: 

COMPANY – SOFTWARE ONLINE It is possible to calculate from our website the index of risk, the protection level and the ESE lightning rod for a total protection.

SCIENCE: 

SCIENCE Sincrotron Laboratory (Barcelona) COMPANY – ENGINEERING Dept .

PowerPoint Presentation: 

COMPANY – ENGINEERING Dept . Projects and lightning rod coverage with the drawings.

PowerPoint Presentation: 

Every building needs a prevention and protection system (external & internal) against lightning according its structure. Installations like Barcelona Airport , Collserola Tower or Calatrava Tower have INGESCO protection. COMPANY – ENGINEERING Dept . Collserola tower Calatrava tower

COMPANY – TECNICAL Dept.: 

COMPANY – TECNICAL Dept . PROTECTION: Coverage studies according the International Standards. Design on the drawings with the lightning rod coverage. Projects of External Lightning Protection in all the world. Inspection of the installations.

COMPANY – EXHIBITIONS: 

COMPANY – EXHIBITIONS

PowerPoint Presentation: 

INSPECTION Dept . NF C 17-102 STANDARD 7.1.- Initial inspection Once the ESE lightning conductor installation is completed, it should be inspected to make sure that it complies with the provisions of this Standard. 7.2.- Scheduled inspection The inspection frequency is determined by the protection level. Note: Lightning flashes can be recorded by a lightning flash counter installed on one of the down-conductors.

INSPECTION ENTITY Dept. : 

INSPECTION ENTITY Dept . Certification for the different phases: Design. Direction of works and installation. Inspection after the installation is completed

INSTALATION Dept. : 

INSTALATION Dept .

PowerPoint Presentation: 

COMPANY- CERTIFICATES ISO Certificate 9001:2000 Research, Development, Manufacturing and Marketing of Lightning Protection and Prevention Systems. Test Laboratory for Evaluation of Lightning Protection and Prevention Systems.

PowerPoint Presentation: 

Certificates of ESE lightning rods (Annex C UNE 21186 & NF C 17-102) COMPANY- CERTIFICATES Initiation Advance Δ T = 54 µs Certificates for the protection radius of the INGESCO ESE lightning rods

PowerPoint Presentation: 

Quality Certificates for all our ESE lightning rods COMPANY- CERTIFICATES

PowerPoint Presentation: 

Seminar by : Duero, 5 - 08223 Terrassa (BARCELONA) Tel. (+34) 93 736 03 14 / Fax (+34) 93 736 03 12 e-mail : export@ingesco.com www.ingesco.com