logging in or signing up Mechanical Ventilation short cindynarak Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: Embed: Flash iPad Copy Does not support media & animations WordPress Embed Customize Embed URL: Copy Thumbnail: Copy The presentation is successfully added In Your Favorites. Views: 3468 Category: Education License: All Rights Reserved Like it (1) Dislike it (1) Added: January 23, 2010 This Presentation is Public Favorites: 1 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Mechanical Ventilation& Clinical application : Mechanical Ventilation& Clinical application กวีวรรณ ลิ้มประยูร หน่วยหออภิบาลผู้ป่วยเด็ก หน่วยโรคระบบทางเดินหายใจ ภาควิชากุมารเวชศสตร์ คณะแพทยศาสตร์ศิริราชพยาบาล Indication : Indication Indication : Respiratory failure To decrease or support work of breathing To improve oxygenation To recruit the lung To support other organs e.g.: increased ICP, CHF Indication Normal value : Normal value Tidal volume 10-12 ml/kg in general or 6-8 ml/kg in ARDS MV 200-300 ml /kg Parts and Humidifiers : Parts and Humidifiers How to set in some situations : How to set in some situations post-operative asthma or BPD pneumonia or ARDS increased ICP Initial Settings : Initial Settings FiO 2 - 1.0 (100% O 2 ) for a patient with lung disease; 0.40 (40% O2 ) for a patient without lung disease. PEEP +6-8 for a patient with lung disease; +4 for a patient without lung disease. RR 30 for infants up to 1 year of age; 20 for those 1-6 years of age and 15 for those greater than 6 (which are the average normal respiratory rates for age). I Time Based upon an I:E ratio of 1:2 for infants and pre-school age children and 1:2.5 for schoolage and adolescents. Therefore, 0.7 sec for infants up to 1 year of age; 1 sec for those to 6 years of age and 1.2 secs for those greater than 6. Tidal Volume 10 cc/kg (Range 8-12 cc/kg). Just a “few” years ago, many patients were started on 15 cc/kg, the volume that seemed to work “best” to prevent atelectasis in adult post-op patients ie those with normal lungs. However, with barotrauma (air leaks) Slide 19: Guidelineในการตั้งเครื่องช่วยหายใจเบื้องต้น (12) 1.เลือก mode ของเครื่องช่วยหายใจที่คุ้นเคยมากที่สุด โดยจุดประสงค์ของการช่วยหายใจคือให้การช่วยหายใจเพื่อทำให้มีการแลกเปลี่ยนกาซที่เพียงพอ (adequate oxygenation/ventilation) ลดงานซึ่งเกิดจากการหายใจ (reduced work of breathing) หายใจมีปฏิสัมพันธ์กับเครื่องช่วยหายใจ (synchrony between patient and ventilator) (12,17) หลีกเลี่ยงการใช้ความดันขนาดสูง (avoidance of high end-inspiration pressures) 2.ควรตั้งปริมาณความเข้มข้นออกซิเจนขนาดสูงก่อน อาจตั้งโดยใช้ออกซิเจน FiO2 1.0 ก่อนแล้วค่อยๆลดขนาดลงเพื่อพยายามคงค่าความอิ่มตัวออกซิเจนในเลือด (oxygen saturation,SaO2) ให้ได้ประมาณ92-95% ในรายที่มีความผิดปกติของปอดรุนแรง เช่นภาวะ Adult Respiratory Distress Syndrome (ARDS) อาจยอมรับที่ค่าค่าความอิ่มตัวออกซิเจนในเลือดมากกว่าหรือเท่ากับ 88% (12,18) Slide 20: 3.เริ่มต้นควรตั้งปริมาตร tidal volume ประมาณ 8-10 ml ต่อน้ำหนักตัว 1 กิโลกรัมในกรณีทั่วไป หรืออาจเริ่มตั้งในขนาด 10-12 ml ต่อน้ำหนักตัว 1 กิโลกรัมในผู้ป่วย neuromuscular disease เพื่อให้การหายใจได้ตามเครื่อง ในรายที่มีความผิดปกติของปอดรุนแรง เช่นภาวะ Adult Respiratory Distress Syndrome (ARDS) อาจเริ่มตั้งที่ขนาด 5-8 ml ต่อน้ำหนักตัว 1 กิโลกรัมและความดันช่วง plateau pressure น้อยกว่า 30 มม.น้ำ 4.เลือกอัตราการหายใจที่เหมาะสมเพื่อให้ได้การหายใจต่อนาทีที่เหมาะสมกับโรคและลักษณะทางคลีนิก โดยปรับผลตามค่าก๊าซในเลือด (17) Slide 21: 5.พยายามปรับใช้ PEEP ในในรายที่มีความผิดปกติของปอดรุนแรงทั่วไป (diffuse lung injury) เพื่อพยายามทำให้การใช้ออกซิเจนลดลง และพยายามหาค่า PEEP ที่เหมาะสม ส่วนใหญ่อยู่ที่ประมาณ 5- 10 มม.น้ำโดย อาจอาศัยดูค่า pressuse-volume curves หรือการเปลี่ยนแปลงของ ปริมาตร tidal volume ค่าก๊าซในเลือด หรือภาพเอกซ์เรย์ปอดเพื่อดู overinflation และควรติดตามผลที่ไม่พึงประสงค์จาก PEEP (5)เช่น barotrauma ความดันเลือดต่ำ หรือการแลกเปลี่ยนก๊าซแย่ลงในกรณี overinflation 6.ตั้งค่าความไวของ trigger ที่เหมาะสมโดยพยายามให้มีปฏิสัมพันธ์ระหว่างผู้ป่วยกับเครื่องช่วยหายใจมากที่สุดโดยที่ ไม่ตั้งต่ำเกินไปจนกระทั่งเกิดเครื่องช่วยหายใจทำงานเอง (autocycling) 7. ควรระมัดระวังในการใช้อัตราส่วนของระยะเวลาหายใจออกที่เหมาะสม ในผู้ป่วยซึ่งมีความเสี่ยงต่อการเกิด air trapping เนื่องจากการเกิด autoPEEP ที่ไม่ต้องการได้ Slide 22: 8.ในกรณีซึ่งผู้ป่วยมีการแลกเปลี่ยนกาซที่ไม่ดีและต้องการเครื่องช่วยหายใจขนาดสูงควรคำนึงถึงการใช้ยานอนหลับขนาดสูงและหรือยาคลายกล้ามเนื้อร่วมด้วย 9.ควรปรึกษาหรือพิจารณาส่งต่อในกรณีที่เกินขีดความสามารถในการดูแลหรือปรับเปลี่ยนไปในสถานที่ซึ่งมีความชำนาญหรือมีศักยภาพในการดูแลผู้ป่วย หรือเพื่อการช่วยหายใจแบบ Non-conventional mechanical ventilation Example 1- post operative : Example 1- post operative Mode: Pressure controlled ventilation PIP 20 cm H2O PEEP 5 cm H2O FiO2 0.5 i Time 1.0 sec Rate 20 / min Example 2- asthma : Mode: Time cycled pressure limited Flow 3 times minute ventilation (Normal MV = 200-300ml/kg) PIP 20 cm H2O PEEP 3 cm H2O FiO2 0.5 i Time 0.6 sec Rate 20 / min Example 2- asthma Alarms : Alarms Alarms : Usually will set 15% more or less MV 200-300 ml /kg Tidal volume 10-12 ml/kg in general or 6-8 ml/kg in ARDS Alarms Alarms : Alarms Pressure alarm for SIMV or volume mode Expired TV alarm and MV alarm for Pressure mode Apnea alarm or high RR alarm Noninvasive mechanical ventiation : Noninvasive mechanical ventiation High frequency mechanical ventilation : High frequency mechanical ventilation Slide 35: Henderson Laminar Indication : Indication 1. To serve as a ventilation mode when conventional ventilation has failed. 2. To provide a mode of ventilation that minimizes barotrauma, or damage, to the delicate tissue in the lungs. Pediatric Indications : Pediatric Indications Neonatal Respiratory Distress Syndrome Persistent Pulmonary Hypertension Neonatal Meconium Aspiration Syndrome Congenital Diaphragmatic Hernia Neonatal Lung Hypoplasia Neonatal Air Leak Syndrome Pediatric ARDS/Pulmonary Interstitial Edema RSV Pneumonia Monitoring : Monitoring BP NIBP/IBP : BP NIBP/IBP CXR : CXR End-tidal CO2 : End-tidal CO2 Bedside pulmonary mechanics : Bedside pulmonary mechanics Weaning : Weaning Weaning : C- Consciousness A- Airway L- Lung M- Muscle strength Weaning Patient Ventilator In coordination(Fight) : Ventilator Malfunction Inappropriate setting Under or Over of Trigger sensitivity Under or Over of Peak flow Under or Over of inspiratory time Inadequate Tidal volume Patient Ventilator In coordination(Fight) You do not have the permission to view this presentation. In order to view it, please contact the author of the presentation.
Mechanical Ventilation short cindynarak Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: Embed: Flash iPad Copy Does not support media & animations WordPress Embed Customize Embed URL: Copy Thumbnail: Copy The presentation is successfully added In Your Favorites. Views: 3468 Category: Education License: All Rights Reserved Like it (1) Dislike it (1) Added: January 23, 2010 This Presentation is Public Favorites: 1 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Mechanical Ventilation& Clinical application : Mechanical Ventilation& Clinical application กวีวรรณ ลิ้มประยูร หน่วยหออภิบาลผู้ป่วยเด็ก หน่วยโรคระบบทางเดินหายใจ ภาควิชากุมารเวชศสตร์ คณะแพทยศาสตร์ศิริราชพยาบาล Indication : Indication Indication : Respiratory failure To decrease or support work of breathing To improve oxygenation To recruit the lung To support other organs e.g.: increased ICP, CHF Indication Normal value : Normal value Tidal volume 10-12 ml/kg in general or 6-8 ml/kg in ARDS MV 200-300 ml /kg Parts and Humidifiers : Parts and Humidifiers How to set in some situations : How to set in some situations post-operative asthma or BPD pneumonia or ARDS increased ICP Initial Settings : Initial Settings FiO 2 - 1.0 (100% O 2 ) for a patient with lung disease; 0.40 (40% O2 ) for a patient without lung disease. PEEP +6-8 for a patient with lung disease; +4 for a patient without lung disease. RR 30 for infants up to 1 year of age; 20 for those 1-6 years of age and 15 for those greater than 6 (which are the average normal respiratory rates for age). I Time Based upon an I:E ratio of 1:2 for infants and pre-school age children and 1:2.5 for schoolage and adolescents. Therefore, 0.7 sec for infants up to 1 year of age; 1 sec for those to 6 years of age and 1.2 secs for those greater than 6. Tidal Volume 10 cc/kg (Range 8-12 cc/kg). Just a “few” years ago, many patients were started on 15 cc/kg, the volume that seemed to work “best” to prevent atelectasis in adult post-op patients ie those with normal lungs. However, with barotrauma (air leaks) Slide 19: Guidelineในการตั้งเครื่องช่วยหายใจเบื้องต้น (12) 1.เลือก mode ของเครื่องช่วยหายใจที่คุ้นเคยมากที่สุด โดยจุดประสงค์ของการช่วยหายใจคือให้การช่วยหายใจเพื่อทำให้มีการแลกเปลี่ยนกาซที่เพียงพอ (adequate oxygenation/ventilation) ลดงานซึ่งเกิดจากการหายใจ (reduced work of breathing) หายใจมีปฏิสัมพันธ์กับเครื่องช่วยหายใจ (synchrony between patient and ventilator) (12,17) หลีกเลี่ยงการใช้ความดันขนาดสูง (avoidance of high end-inspiration pressures) 2.ควรตั้งปริมาณความเข้มข้นออกซิเจนขนาดสูงก่อน อาจตั้งโดยใช้ออกซิเจน FiO2 1.0 ก่อนแล้วค่อยๆลดขนาดลงเพื่อพยายามคงค่าความอิ่มตัวออกซิเจนในเลือด (oxygen saturation,SaO2) ให้ได้ประมาณ92-95% ในรายที่มีความผิดปกติของปอดรุนแรง เช่นภาวะ Adult Respiratory Distress Syndrome (ARDS) อาจยอมรับที่ค่าค่าความอิ่มตัวออกซิเจนในเลือดมากกว่าหรือเท่ากับ 88% (12,18) Slide 20: 3.เริ่มต้นควรตั้งปริมาตร tidal volume ประมาณ 8-10 ml ต่อน้ำหนักตัว 1 กิโลกรัมในกรณีทั่วไป หรืออาจเริ่มตั้งในขนาด 10-12 ml ต่อน้ำหนักตัว 1 กิโลกรัมในผู้ป่วย neuromuscular disease เพื่อให้การหายใจได้ตามเครื่อง ในรายที่มีความผิดปกติของปอดรุนแรง เช่นภาวะ Adult Respiratory Distress Syndrome (ARDS) อาจเริ่มตั้งที่ขนาด 5-8 ml ต่อน้ำหนักตัว 1 กิโลกรัมและความดันช่วง plateau pressure น้อยกว่า 30 มม.น้ำ 4.เลือกอัตราการหายใจที่เหมาะสมเพื่อให้ได้การหายใจต่อนาทีที่เหมาะสมกับโรคและลักษณะทางคลีนิก โดยปรับผลตามค่าก๊าซในเลือด (17) Slide 21: 5.พยายามปรับใช้ PEEP ในในรายที่มีความผิดปกติของปอดรุนแรงทั่วไป (diffuse lung injury) เพื่อพยายามทำให้การใช้ออกซิเจนลดลง และพยายามหาค่า PEEP ที่เหมาะสม ส่วนใหญ่อยู่ที่ประมาณ 5- 10 มม.น้ำโดย อาจอาศัยดูค่า pressuse-volume curves หรือการเปลี่ยนแปลงของ ปริมาตร tidal volume ค่าก๊าซในเลือด หรือภาพเอกซ์เรย์ปอดเพื่อดู overinflation และควรติดตามผลที่ไม่พึงประสงค์จาก PEEP (5)เช่น barotrauma ความดันเลือดต่ำ หรือการแลกเปลี่ยนก๊าซแย่ลงในกรณี overinflation 6.ตั้งค่าความไวของ trigger ที่เหมาะสมโดยพยายามให้มีปฏิสัมพันธ์ระหว่างผู้ป่วยกับเครื่องช่วยหายใจมากที่สุดโดยที่ ไม่ตั้งต่ำเกินไปจนกระทั่งเกิดเครื่องช่วยหายใจทำงานเอง (autocycling) 7. ควรระมัดระวังในการใช้อัตราส่วนของระยะเวลาหายใจออกที่เหมาะสม ในผู้ป่วยซึ่งมีความเสี่ยงต่อการเกิด air trapping เนื่องจากการเกิด autoPEEP ที่ไม่ต้องการได้ Slide 22: 8.ในกรณีซึ่งผู้ป่วยมีการแลกเปลี่ยนกาซที่ไม่ดีและต้องการเครื่องช่วยหายใจขนาดสูงควรคำนึงถึงการใช้ยานอนหลับขนาดสูงและหรือยาคลายกล้ามเนื้อร่วมด้วย 9.ควรปรึกษาหรือพิจารณาส่งต่อในกรณีที่เกินขีดความสามารถในการดูแลหรือปรับเปลี่ยนไปในสถานที่ซึ่งมีความชำนาญหรือมีศักยภาพในการดูแลผู้ป่วย หรือเพื่อการช่วยหายใจแบบ Non-conventional mechanical ventilation Example 1- post operative : Example 1- post operative Mode: Pressure controlled ventilation PIP 20 cm H2O PEEP 5 cm H2O FiO2 0.5 i Time 1.0 sec Rate 20 / min Example 2- asthma : Mode: Time cycled pressure limited Flow 3 times minute ventilation (Normal MV = 200-300ml/kg) PIP 20 cm H2O PEEP 3 cm H2O FiO2 0.5 i Time 0.6 sec Rate 20 / min Example 2- asthma Alarms : Alarms Alarms : Usually will set 15% more or less MV 200-300 ml /kg Tidal volume 10-12 ml/kg in general or 6-8 ml/kg in ARDS Alarms Alarms : Alarms Pressure alarm for SIMV or volume mode Expired TV alarm and MV alarm for Pressure mode Apnea alarm or high RR alarm Noninvasive mechanical ventiation : Noninvasive mechanical ventiation High frequency mechanical ventilation : High frequency mechanical ventilation Slide 35: Henderson Laminar Indication : Indication 1. To serve as a ventilation mode when conventional ventilation has failed. 2. To provide a mode of ventilation that minimizes barotrauma, or damage, to the delicate tissue in the lungs. Pediatric Indications : Pediatric Indications Neonatal Respiratory Distress Syndrome Persistent Pulmonary Hypertension Neonatal Meconium Aspiration Syndrome Congenital Diaphragmatic Hernia Neonatal Lung Hypoplasia Neonatal Air Leak Syndrome Pediatric ARDS/Pulmonary Interstitial Edema RSV Pneumonia Monitoring : Monitoring BP NIBP/IBP : BP NIBP/IBP CXR : CXR End-tidal CO2 : End-tidal CO2 Bedside pulmonary mechanics : Bedside pulmonary mechanics Weaning : Weaning Weaning : C- Consciousness A- Airway L- Lung M- Muscle strength Weaning Patient Ventilator In coordination(Fight) : Ventilator Malfunction Inappropriate setting Under or Over of Trigger sensitivity Under or Over of Peak flow Under or Over of inspiratory time Inadequate Tidal volume Patient Ventilator In coordination(Fight)