BS6622/BS7835 IEC60502 VDE0276 MV Cables

Views:
 
Category: Entertainment
     
 

Presentation Description

BS6622/BS7835 IEC60502 VDE0276 cables Single Core 6.35/11KV (Um=12KV) Single Core 8.7/15KV (Um=17.5kV) Single Core 12.7/22KV (Um=24kV) Single Core 19/33KV (Um=36kV)

Comments

Presentation Transcript

slide 1:

Address: Marchants Industrial Centre MiII Lane Laughton Lewes East Sussex BN8 6AJ UK Tel: 44-207-4195087 Fax: 44-207-8319489 E-mail: salescaledonian-cables.co.uk www.caledonian-cables.co.uk Medium Voltage Cables

slide 2:

Caledonian develops manufactures and markets a totally integrated product line of Medium Voltage Cables for a diverse variety of technological applications. The company offers an unrivalled experience and vast product range developed organically at the leading edge of technology. It manufactures a variety of products which include medium voltage power cables low voltage power and control cables instrumentation cables pilot cables building wires fexible cables. It can also offer cables with special features like flame retardant properties low smoke halogen free LSZH properties cables with anti-termite treatment UV resistant outer sheath etc being suitable for different types of applications or environmental conditions. Caledonian holds several important international approvals and manufactures its products in accordance with relevant IEC VDE CENELEC and British Standard. The quality management system is accredited to ISO 9001. Caledonian has maintained an enviable growth record year on year. The products manufactured by Caledonian are sold not only in Europe by also beyond to Australia China Japan South Korea Arab countries. They have been installed in variety of applications including power plants oil refneries petroleum gas facilities hospitals hotels airports etc. This catalogue contains technical information on all medium voltage cables including armoured and unarmoured designs single and multicore constructions and different sheathing and screening options. All cable designs outlined in this section follow the constructions covered by IEC 60502 BS 6622 and VDE 0276. However Caledonian can also supply a range of alternative designs to meet specific customer needs including different sheathing screening armouring and sheath color options together with enhanced fre performance water sealing of conductors and screens and added environmental protection. Cables can be made to individual customer specifcations or other recognized standards. These standards include ICEA S-66-524 WC 7 AS 1429 JIS C 3606 EDF HN 33-S-23 ASTM etc. Company Profle Caledonian Medium Voltage Cables

slide 3:

Table of Contents I II III IV V I Cable Properties Construction 03 Cable Machinery Equipments 05 Product Testing 06 Cable Options Ordering Information 09 II Medium Voltage Cables to BS 6622/BS 7835 Single Core Cables to BS 6622/BS 7835 Three Core Cables to BS 6622/BS 7835 12 30 III Medium Voltage Cables to IEC 60502 Single Core Cables to IEC 60502 Three Core Cables to IEC 60502 31 59 IV Medium Voltage Cables to VDE 0276 Single Core Cables to VDE 0276 Three Core Cables to VDE 0276 60 86 V Technical Information 87 95

slide 4:

I I II III IV V Cable Properties Construction Cable Machinery Equipments Product Testing Cable Options Ordering Information Caledonian Medium Voltage Cables

slide 5:

03 www.caledonian-tech.com www.caledonian-tech.net Cable Properties Construction ▓ Cable Properties Special features which we can offer for MV cables: Ì Watertight construction both radial and longitudinal. Ì Lead sheath available for options. Ì Resistant to heavy vibration. Ì Available in long delivery lengths to reduce number of joints. Ì Corrosion-free screen area. Ì Copper or aluminum conductor up to 2000mm². Ì Metallic sheath and radial moisture barrier made of copper wire or tape. Ì Different options for outer PE jackets LDPE MDPE HDPE. Ì Different options for LSF LSZH FRPVC being anti-termite or UV resistant as per BS 7835 IEC 60332 etc. Ì Strippable insulation screen. Ì Metallic screen made of multiple layers of copper tapes or a combination of copper wires and tapes to increase the earth fault current carrying capacity. Ì Increased armour conductivity by insertion of hard drawn copper wires in armour. ▓ Cable Construction Caledonian medium voltage cables are manufactured using the monosil process. Caledonian provides the highly specialized plant state-of-the-art research facilities and meticulous quality control procedures that are required for the manufacturing of PVC insulated cables for use up to 6KV and XLPE/EPR insulated cables for use at voltages up to 42 KV. The materials are all kept in cleanliness-controlled conditions throughout the production process in order to ensure the absolute homogeneity of the fnished insulation materials. Conductors Either aluminium or copper conductors are used. Conductors up to 800mm² will be circular compacted stranded and shall comply with IEC 60228 class 2. 1000mm² conductor will be circular stranded type on which a layer of semi-conducting tape will be applied. Conductor Screen This will be an extruded layer of semi-conducting crosslinkable compound applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen. The triple extrusion is a single high precision operation that eliminates the possibility of any contamination between the layers which could create irregularities in the electrical field. By careful material selection and special attention to process parameters Caledonian produces the insulation screen layers with the required degree of stripping force as stipulated by the applicable national or international standard.

slide 6:

Caledonian Medium V oltage Cables Insulation This will be an extruded layer of XLPE or EPR applied over conductor screen under triple extrusion process along with conductor screen and insulation screen. PVC may be used for 1.8/3KV and 3.6/6KV cables. Insulation Screen This will be a layer of semi-conducting crosslinkable compound which will be applied by triple extrusion process over the insulation. Metallic Screen It will consist of a layer of copper tape applied helically with overlap over insulation screen. Other combinations of metallic screens as per customer’s requirement can also be provided on request. Laying-Up In case of three core cables the three cores are laid up with non-hygroscopic fillers like polypropylenePP fllers at interstices and a binder tape is applied with an overlap. These binder tapes can be of PVC or foamed Polyethylene. Inner Sheath Bedding for Armoured Cables Extruded layer of PVC or PE is applied over the laid up cores for armoured cables. PVC is normally of grade ST2 and PE of grade ST7 as per IEC 60502 Part 2. Armouring In case of armoured cables the armour is applied helically over inner sheath. For single core cables it is of aluminium wires and for multicore cables the armour can be of one among the following options: a Galvanized steel wire. b Galvanized steel tape. c Galvanized steel strip. Over Sheath An extruded layer is applied over the armour in case of armoured cables and over laid up cores in case of unarmoured cables. Outer sheath material can be either PVC PE HDPE or MDPE. Caledonian medium voltage cables are normally supplied with red PVC over sheaths complying with BS 6622 or IEC 60502. Other colors may be provided to suit a range of installation considerations such as the effect of UV radiations and differing soil compositions. Anti-termite formulations can also be supplied in addition to graphite-coated over sheaths where on-site testing of the sheath is required. Fire Performance on Cable Sheaths Cables can also be supplied with special flame retardant PVC over sheaths to comply with the IEC 60332 standard. We can also supply cables with Low Smoke Halogen Free LSZH sheaths according to BS 7211 and BS 6724 standards or other equivalent

slide 7:

05 Cable Machinery Equipments international standards. ▓ Cable Machinery Equipments The MV cable manufacturing facility at Caledonian is the most modern facility available today with the state of the art machinery equipments. The entire MV cables manufacturing plant at Caledonian is fully air-conditioned with humidity control to ensure contamination free atmosphere. The heart of MV cable manufacturing facility is the CCV line. This line supplied by Troester Germany and which incorporates some of the most modern features like - Triple extrusion head to ensure superior quality of extrusion and uniform bonding of conductor screen XLPE insulation and the insulation screen. - CDCC – Completely dry curing cooling in an inert atmosphere of nitrogen. - In line X-ray machine for checking proper concentricity as well as measuring thickness of extruded materials. - Fully computerized auto-cure control system which controls all driving parameters to achieve best curing of extruded materials. - Fully automatic compound handling system in a positive pressure atmosphere ensuring a contamination free line which is absolutely essential to achieve superior quality product. Some of the other machines include: - Drawing machine from Niehoff Germany - Cable stranding machine from Mali Austria - Screening machine from Ceeco Canada - Five drum cabling machine from Mali Austria - Armouring machine from Ceeco Canada - Extruder from Troester Germany etc. With the manufacturing facilities incorporating the use of latest available technology the MV cables offered by Caledonian provides customers with a defnite advantage in terms of: - Compete adherence to specifcations - Superior overall performance - Minimum risk of insulation failures - Longer service life - Triple head extrusion. www.caledonian-tech.com www.caledonian-tech.net

slide 8:

Caledonian Medium V oltage Cables ▓ Product Testing Caledonian has made major investment in the testing facilities for its MV cables factory. We have equipped ourselves with the latest and most advanced cable testing facility available in the world. Our major testing facilities include: a DC withstand voltage test system from Hipotronics USA. b Partial discharge test system from Haefely Switzerland. c HV test system from Haefely Switzerland. d On line conductor resistance meter from Aesa Switzerland Effective quality assurance procedures are essential to ensure the consistency and long term reliability and performance of all products. Caledonian always recognises the importance of quality assurance and this commitment is refected in the company achievement of ISO 9001 certification. The design validation for our MV Cables has been done at recognized international laboratories. With the above state of the art testing facility we can conduct all type routine as well as special tests mentioned in IEC 60502 Part 2 BS 6622 other international specifcations in- house. While 100 of the cables are tested for routine tests prior to dispatch however upon customers’ request other type/special tests can be carried out in house or by any third party laboratory. The tests can be divided into different categories: Type Tests The type test is conducted by KEMA Netherlands to validate a special cable design type. Electrical type tests include the following: - Partial discharge test IEC 60502 clause 18.1.3 - Bending test IEC 60502 clause18.1.4 - Sheath measurement IEC 60502 clause 18.1.5 - Heating cycle test IEC 60502 clause 18.1.6 - Impulse withstand test followed by a.c. voltage test IEC 60502 18.1.7 - High voltage test for 4 hours IEC 60502 clause 18.1.8 - Resistivity of semiconducting screens IEC 60502 clause 18.1.9 Non electrical type tests include the following: - All non electrical type tests as required by IEC 60502 Routine Tests Routine tests are carried out on each fnished length of cable to control the overall quality of the cable. They comprise: - Measurement of dimensions. - Measurement of conductor resistance: the D.C. resistance of each conductor when corrected to 20°C and 1 Km shall not exceed the appropriate maximum value specifed in IEC 60228 respectively.

slide 9:

07 Product Testing - Measurement of screen resistance. - High voltage test: an a.c. voltage of 3.5 Uo shall be applied for 5 minutes between each conductor and metallic screen. No breakdown shall occur. - Partial discharge test: the magnitude of discharge at 1.73 Uo shall not exceed 10pC. - Measurement of dielectric losses and capacity. Special Tests Special tests are carried out on 10 of the lengths for each production lot in any case on one length. They are carried out if major changes in design are introduced. They comprise: - Measurement of dimensions - Checking sheath identifcation - Testing shrinkage of PE sheath - Conductor examination - Carrying out voltage test - Carrying out hot set test for XLPE insulation At Caledonian quality assurance is an integrated part of the production process and maintained from order entry and manufacture through to testing packaging and shipping. All quality assurance procedures are regularly audited by recognised quality organisations and all routine voltage testing is carried to more stringent levels than that required by international standards. Specifcation for testing is designed in accordance to the following international standards: - IEC 60502 - IEC 60811 - BS 5368 - DIN 56283/VDE 0273 - EDF HN 33S23 - ASJIS - ASTM - etc. We have also installed many in line devices/facilities for checking the product quality during the manufacturing process like the X-ray machine installed in the CCV line curing optimization software etc to avoid any risk or failure to ensure a long service life for our products. With these modern equipment facilities we ensure to maintain close manufacturing tolerances high accuracy to customer specifications as well as effective monitoring of the entire manufacturing process to offer a world class product. www.caledonian-tech.com www.caledonian-tech.net

slide 10:

Caledonian Medium V oltage Cables The following In-Process testing is conducted during the cable manufacturing : Ì Tandem Line Ì Visual and physical tests Ì Electrical tests Ì Resistance resistance unbalance tests Ì Open short circuit test Ì High Voltage Test Ì Group twinner Ì Visual physical tests Ì Electrical tests Ì Resistance resistance unbalance tests Ì Mutual capacitance test Ì Open short circuit test Ì Insulation resistance test Ì Sheathing Ì Dimensional test Ì Water penetration test Ì Spark test Ì Overlaps seal bonding inspection Ì Armoring Ì Dimensional test Ì Visual inspection Ì Jacketing Ì Dimensional test Ì Overlap inspection Ì Spark test Ì Final Testing Ì Routine testing Ì Resistance resistance unbalance tests Ì Mutual capacitance test Ì Transmission test Ì Capacitance capacitance unbalance tests pair to pair and pair to ground Ì Attenuation cross talk tests.

slide 11:

09 Cable Options Ordering Information ▓ Cable Options It is essential that the type of cable ordered is suitable for its intended use. Cable choice will be based on a whole range of factors including installation requirements relevant local regulations and the electrical characteristics of appropriate cable types. The factors to be considered are: Ì Nominal voltage of system. Ì Highest voltage of system. Ì Impulse withstand voltage. Ì System frequency. Ì Maximum rated current. Ì For continous operation. - For cyclic operation a load curve is essential - For overload operation if any duration is essential Ì Symmetrical and asymmetrical short circuit current both between pulses and to earth. Ì Duration of fault in second. Ì Required screen bonding scheme - Both ends bonded - Single point bonded - Cross bonded ▓ Ordering Information VDE CODE: ABCDEFGH A. Conductor N- Standard construction in accordance to VDE standard copper conductor NA- Aluminium conductor NFA- Standard construction for twisted cable aluminium conductor B. Insulation Material Y- PVC 2X- XLPE 3G- EPR C. Concentric Conductor Shielding Material C- Concentric conductors of copper wires and copper tape helically wounded CW- Concentric conductors of copper wires in waveconal formation and and copper tape helically wounded CE- Concentric conductors of copper wires and copper tape over each individual conductor helically wounded Blank- No screen www.caledonian-tech.com www.caledonian-tech.net

slide 12:

Caledonian Medium V oltage Cables D.Shielding Material S- Shielding of copper wires and copper tape helically wounded SE- Shielding of copper wires and copper tape over each individual conductor helically wounded F- Longitudinally water proof shielding Blank- No screen E. Bedding Material 2Y- PE Y- PVC H- LSZH K- Lead sheath Blank- No bedding F. Armoring Material B- Double steel tape armouring R- Round steel wire armouring F- Flat steel wire armouring Gb- Helical steel tape armouring Blank- No armour G. Jacket Material 2Y- PE Y- PVC H- LSZH K- Lead sheath H. Cable Types J- Cables with green-yellow conductor are marked with protective conductor O- Cables without green-yellow conductor are marked without protective conductor Caledonian Order Code MVA-BCDEFGH-IJ A Cable Design Standard 6622- BS6622 standard 7835- BS7835 standard 502- IEC60502 standard 276- VDE0276 standard B Conductor A- Aluminium conductor Blank- Copper conductor

slide 13:

11 Cable Options Ordering Information C Insulation Material Y- PVC 2X-XLPE 3G-EPR D Concentric Conductor Shielding Material C- Concentric conductors of copper wires and copper tape helically wounded CW- Concentric conductors of copper wires in waveconal formation and and copper tape helically wounded CE- Concentric conductors of copper wires and copper tape over each individual conductor helically wounded Blank- No screen E Shielding Material S- Shielding of copper wires and copper tape helically wounded SE- Shielding of copper wires and copper tape over each individual conductor helically wounded F- Longitudinally water proof shielding Blank- No screen F Bedding Material 2Y- PE Y- PVC H- LSZH K- Lead sheath Blank- No bedding G Armoring Material B- Double steel tape armouring R- Round steel wire armouring F- Flat steel wire armouring Gb- Helical steel tape armouring Blank- No armour H Jacket Material 2Y- PE Y- PVC H- LSZH K- Lead Sheath I No of Cores 3C- 3 Cores J Conductor Size 185- 185 sq mm 8A- 8AWG www.caledonian-tech.com www.caledonian-tech.net

slide 14:

II I II III IV V Medium Voltage Cables to BS 6622/BS 7835 Single Core Cables to BS 6622/BS 7835 Three Core Cables to BS 6622/BS 7835 Caledonian Medium Voltage Cables

slide 15:

13 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Single Core Cables to BS 6622/BS 7835 ▓ APPLICATIONS: The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.8/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations indoors and in cable ducts outdoors underground and in water as well as for installation on cable trays for industries switchboards and power stations. ▓ STANDARD: BS 6622 BS 7835 LSZH Version ▓ CONSTRUCTION: Conductor: Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded class 2 and aluminium conductors shall be either solid or stranded class 2. Conductor Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm and the maximum resistivity shall not exceed 500 Ohm-m at 90°C. Insulation: Insulation is of cross-linked polyethylene compound XLPE GP8 conforming to BS 7655-1.3 or EPR GP7 conforming to BS 7655-1.2. Table 1. Insulation Thickness Nom. Cross Section Area Insulation Thickness at Nominal Voltage 3.8/6.6KV Um7.2KV 6.35/11KV Um12KV 8.7/15KVUm17.5KV 12.7/22KVUm24KV 19/33KVUm36KV mm² mm mm mm mm mm 70 – 185 2.5 3.4 4.5 5.5 8.0 240 2.6 3.4 4.5 5.5 8.0 300 2.8 3.4 4.5 5.5 8.0 400 3.0 3.4 4.5 5.5 8.0 Above 500 3.2 3.4 4.5 5.5 8.0 PVC/PE/LSZH Over Sheath Aluminium Wire Armour optional Binder XLPE/EPR Insulation Conductor Conductor Screen Insulation Screen Metallic Screen PVC/PE/LSZH Separation Sheath optional

slide 16:

Caledonian Medium V oltage Cables Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly ftted to the insulation to exclude all air voids and can be easily hand stripped on site. Metallic Layer: The metallic layer shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The metallic layer provides an earth fault current path capable of withstanding fault current to earth of 1000A for one second at maximum temperature 160°C. Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires copper tape with minimum thickness of 0.1mm can be applied helically with overlap. Total cross section of copper wire screen layer is shown in table 2. Table 2. Minimum Total Cross Section of Copper Wire Screen DC Resistance of the Screen Nominal Cross-Section of Cables Minimum Cross-Section of Copper Wire Screen DC Resistance of the Copper Wire Screen at 20°C mm² mm² Ω up to 120 16 1.06 150-300 25 0.72 400-630 35 0.51 Separation Sheath for armoured cable: The separation sheath comprises a layer of extruded PVC PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fctitious diameter under the sheath in mm. The nominal separation sheath thickness shall not be less than 1.2mm. Armour for armoured cable: The armour consists of round aluminium wire with diameter specifed as in Table 3. Table 3. Armour Wire Diameter Fictitious Diameter under the Armour Armour Wire Diameter mm mm 25 1.6 25 35 2.0 35 60 2.5 60 - 3.15 Over Sheath: Overall sheath comprises a layer of extruded either PVC type 9 conforming to BS 7665-4.2 or MDPE type TS2 conforming to BS 7655-10.1. LSZH can be offered as an option. The over sheath is normally black in colour. When a DC voltage test is to be performed on the over sheath a semi-conducting layer such as graphite coating shall be applied over the surface of the extruded over sheath. The nominal over sheath thickness is

slide 17:

15 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 calculated by 0.035+D where D is the diameter immediately under the over sheath in mm. For cables with the over sheath not applied over the armour the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour the nominal over sheath thickness shall not be less than 1.8mm. ▓ PHYSICAL PROPERTIES: Operating Temperature: up to 90°C Temperature Range: -5°C PVC or LSZH sheath -20°C PE sheath Short Circuit Temperature: 250°C short circuit duration up to 5 seconds Bending Radius: 12 x OD Table 4. Nominal /Operating /Test Voltages Rated Voltage Uo/U Operating Voltage Um Testing Voltage rms 3.8/6.6KV 7.2KV 15KV 6.35/11KV 12KV 25.5KV 8.7/15KV 17.5KV 35KV 12.7/22KV 24KV 51KV 19/33KV 36KV 76KV

slide 18:

Caledonian Medium V oltage Cables Single Core 3.8/6.6KV Um7.2KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 25 2.5 16 1.5 20.3 750 580 3.4 1.2 1.6 1.8 26.3 1150 1000 35 2.5 16 1.6 21.3 870 650 3.6 1.2 1.6 1.8 27.3 1250 1050 50 2.5 16 1.6 22.4 1090 770 3.9 1.2 1.6 1.8 28.4 1500 1190 70 2.5 16 1.7 24.2 1310 870 4.3 1.2 1.6 1.8 30.0 1740 1300 95 2.5 16 1.7 25.8 1560 960 4.7 1.2 1.6 1.9 31.8 2030 1430 120 2.5 16 1.8 27.4 1830 1070 5.0 1.2 1.6 1.9 33.2 2310 1550 150 2.5 25 1.8 29.1 2130 1190 5.3 1.2 1.6 2.0 35.1 2660 1720 185 2.5 25 1.9 30.8 2490 1320 5.8 1.2 2.0 2.0 37.4 3120 1950 240 2.6 25 1.9 33.5 3040 1520 6.3 1.2 2.0 2.1 40.3 3740 2200 300 2.8 25 2.0 36.1 3650 1770 7.0 1.2 2.0 2.2 42.9 4400 2520 400 3.0 35 2.2 40.6 4680 2170 7.7 1.2 2.0 2.3 47.2 5490 2960 500 3.2 35 2.3 43.6 5670 2570 8.5 1.3 2.5 2.5 51.6 6760 3660 630 3.2 35 2.4 48.8 6980 2990 9.5 1.4 2.5 2.6 57.0 8200 4160 Electrical Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper T ape Screen 1 sec Reactance Inductance Impedance Trefoil Flat spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m µΩ/m nH/m nH/m µΩ/ m µΩ/m 25 727/1200 927/1538 3.6/2.3 263 0.32 2.6 0.4 136 194 400 590 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 291 0.35 2.6 0.5 127 185 390 580 679 1121 695 1131 50 387/641 494/822 6.8/4.4 321 0.39 2.6 0.5 121 179 380 570 511 834 527 844 70 268/443 343/568 9.8/6.3 371 0.45 2.6 0.6 115 173 370 550 364 583 386 597 95 193/320 248/410 13.3/8.5 417 0.50 2.6 0.6 110 168 350 540 272 427 300 446 120 153/253 196/325 17.2/11.0 459 0.55 2.6 0.7 107 165 340 520 225 345 257 367 150 124/206 159/265 21.2/13.5 494 0.59 4.3 0.7 103 161 330 510 193 287 229 313 185 99.1/164 128/211 26.6/17.0 543 0.65 4.3 0.8 100 158 320 500 165 237 206 267 240 75.4/125 98/161 34.9/22.3 583 0.70 4.3 0.9 97 155 310 490 140 191 185 226 300 60.1/100 80/130 43.8/28.0 602 0.72 4.3 1.0 95 153 300 490 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 627 0.75 5.8 1.1 92 150 290 480 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 654 0.79 5.8 1.2 90 149 290 470 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 726 0.87 5.8 1.3 87 145 280 460 97 110 151 160

slide 19:

17 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Single Core 6.35/11KV Um12KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 25 3.4 16 1.5 22.1 960 740 3.8 1.2 1.6 1.8 28.1 1300 780 35 3.4 16 1.6 23.3 1060 790 4.1 1.2 1.6 1.8 29.1 1400 1180 50 3.4 16 1.7 24.4 1160 840 4.4 1.2 1.6 1.8 30.2 1600 1280 70 3.4 16 1.7 26.0 1370 930 4.7 1.2 1.6 1.9 32.0 1840 1400 95 3.4 16 1.8 27.8 1640 1040 5.2 1.2 1.6 1.9 33.6 2130 1530 120 3.4 16 1.8 29.2 1900 1140 5.5 1.2 1.6 2.0 35.2 2430 1670 150 3.4 25 1.9 31.1 2220 1280 5.8 1.2 1.6 2.1 37.9 2870 1930 185 3.4 25 1.9 32.6 2570 1410 6.2 1.2 2.0 2.1 39.4 3240 2080 240 3.4 25 2.0 35.3 3130 1610 6.8 1.2 2.0 2.2 42.1 3490 2330 300 3.4 25 2.1 37.5 3730 1850 7.3 1.2 2.0 2.2 44.1 4490 2560 400 3.4 35 2.2 41.4 4730 2200 8.0 1.2 2.0 2.4 48.2 5589 3040 500 3.4 35 2.3 44.0 5700 2600 8.6 1.3 2.5 2.5 52.0 6780 3680 630 3.4 35 2.4 49.2 7010 3020 9.5 1.4 2.5 2.6 57.4 8230 4200 Electrical Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m µΩ/m nH/m nH/m µΩ/m µΩ/m 25 727/1200 927/1538 3.6/2.3 208 0.42 2.6 0.5 146 206 440 640 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 229 0.46 2.6 0.6 138 201 440 640 679 1121 695 1131 50 387/641 494/822 6.8/4.4 252 0.50 2.6 0.6 132 195 420 620 511 834 527 844 70 268/443 343/568 9.8/6.3 288 0.58 2.6 0.7 122 188 390 600 364 583 386 597 95 193/320 248/410 13.3/8.5 323 0.65 2.6 0.7 122 182 390 580 272 427 300 446 120 153/253 196//325 17.2/11.0 353 0.71 2.6 0.8 116 172 370 550 225 345 257 367 150 124/206 159/265 21.2/13.5 380 0.76 4.3 0.8 110 166 350 530 193 287 229 313 185 99.1/164 128/211 26.6/17.0 416 0.83 4.3 0.9 107 166 340 530 165 237 206 267 240 75.4/125 98/161 34.9/22.3 460 0.92 4.3 0.9 104 163 330 520 140 191 185 226 300 60.1/100 80/130 43.8/28.0 506 1.01 4.3 1.0 100 157 320 500 126 163 174 203 400 47/77.8 64/102 57.3/36.6 561 1.12 5.8 1.1 94 154 300 490 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 619 1.24 5.8 1.2 91 151 290 480 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 698 1.37 5.8 1.3 91 148 290 470 97 110 151 160

slide 20:

Caledonian Medium V oltage Cables Single Core 8.7/15KV Um17.5KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 25 4.5 16 1.6 23.7 940 820 4.4 1.2 1.6 1.8 30.3 1430 1210 35 4.5 16 1.7 24.9 1140 870 4.7 1.2 1.6 1.9 31.5 1630 1310 50 4.5 16 1.7 26.6 1240 920 4.9 1.2 1.6 1.9 32.6 1730 1410 70 4.5 16 1.8 28.4 1470 1030 5.3 1.2 1.6 1.9 34.2 1970 1520 95 4.5 16 1.9 30.2 1750 1160 5.7 1.2 2.0 2.0 36.8 2370 1770 120 4.5 16 1.9 31.6 2100 1250 6.1 1.2 2.0 2.1 38.4 2670 1910 150 4.5 25 2.0 33.5 2340 1400 6.4 1.2 2.0 2.1 40.1 3020 2080 185 4.5 25 2.0 35.0 2690 1520 6.8 1.2 2.0 2.2 41.8 3420 2240 240 4.5 25 2.1 36.8 3270 1740 7.4 1.2 2.0 2.3 44.5 4050 2500 300 4.5 25 2.2 39.9 3870 1990 7.9 1.2 2.0 2.3 46.5 4680 2780 400 4.5 35 2.3 43.8 4890 2370 8.5 1.3 2.5 2.5 51.8 5970 3430 500 4.5 35 2.4 46.4 5860 2760 9.2 1.3 2.5 2.6 54.4 7010 3910 630 4.5 35 2.5 51.6 7190 3190 10.0 1.4 2.5 2.7 59.8 8480 4420 Electrical Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capac- itance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m µΩ/m nH/m nH/m µΩ/m µΩ/m 25 727/1200 927/1538 3.6/2.3 171 0.47 2.6 0.6 154 217 480 680 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 187 0.51 2.6 0.6 145 208 460 660 679 1121 695 1131 50 387/641 494/822 6.8/4.4 204 0.56 2.6 0.7 138 201 440 640 511 834 527 844 70 268/443 343/568 9.8/6.3 232 0.63 2.6 0.7 132 188 420 600 364 583 386 597 95 193/320 248/410 13.3/8.5 258 0.70 2.6 0.8 126 182 400 580 272 427 300 446 120 153/253 196/325 17.2/11.0 281 0.77 2.6 0.8 119 179 380 570 225 345 257 367 150 124/206 159/265 21.2/13.5 301 0.82 4.3 0.9 113 176 360 560 193 287 229 313 185 99.1/164 128/211 26.6/17.0 329 0.90 4.3 0.9 110 170 350 540 165 237 206 267 240 75.4/125 98/161 34.9/22.3 363 0.99 4.3 1.0 107 166 340 530 140 191 185 226 300 60.1/100 80/130 43.8/28.0 398 1.09 4.3 1.1 104 160 330 510 126 163 174 203 400 47/77.8 64/102 57.3/36.6 439 1.20 5.8 1.2 97 157 310 500 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 483 1.32 5.8 1.3 94 154 300 490 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 534 1.46 5.8 1.4 91 151 290 480 97 110 151 160

slide 21:

19 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Single Core 12.7/22KV Um24KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 35 5.5 16 1.7 27.4 1100 800 5.2 1.2 1.6 1.9 31.4 1400 1200 50 5.5 16 1.8 28.8 1330 1010 5.4 1.2 1.6 2.0 34.8 1850 1540 70 5.5 16 1.9 30.6 1570 1130 5.9 1.2 2.0 2.0 37.2 2190 1750 95 5.5 16 1.9 32.2 1840 1240 6.2 1.2 2.0 2.1 39.0 2510 1900 120 5.5 16 2.0 33.8 2120 1360 6.6 1.2 2.0 2.1 40.4 2810 2040 150 5.5 25 2.0 35.5 2440 1500 6.9 1.2 2.0 2.2 42.3 3180 2240 185 5.5 25 2.1 37.2 2810 1640 7.4 1.2 2.0 2.2 43.8 3560 2380 240 5.5 25 2.2 39.9 3390 1860 7.8 1.2 2.0 2.3 46.5 4200 2640 300 5.5 25 2.2 41.9 3990 2110 8.4 1.3 2.5 2.4 49.9 5030 3130 400 5.5 35 2.3 45.8 5100 2490 9.0 1.3 2.5 2.5 53.8 6140 3600 500 5.5 35 2.4 48.4 6000 2900 9.7 1.4 2.5 2.6 56.6 7210 4100 630 5.5 35 2.5 53.6 7340 3340 10.4 1.4 2.5 2.8 62.0 8700 4650 Electrical Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m µΩ/m nH/m nH/m µΩ/m µΩ/m 35 524/868 668/1113 5.0/3.2 162 0.7 2.6 0.7 147 207 470 620 679 1121 695 1131 50 387/641 494/822 6.8/4.4 177 0.8 2.6 0.8 141 201 450 640 511 834 527 844 70 268/443 343/568 9.8/6.3 200 0.8 2.6 0.8 135 195 430 620 364 583 386 597 95 193/320 248/410 13.3/8.5 222 0.9 2.6 0.9 129 188 410 600 272 427 300 446 120 153/253 196/325 17.2/11.0 241 0.9 2.6 0.9 122 182 390 580 225 345 257 367 150 124/206 159/265 21.2/13.5 257 1.0 4.3 1.0 116 176 370 560 193 287 229 313 185 99.1/164 128/211 26.6/17.0 280 1.0 4.3 1.0 116 173 370 550 165 237 206 267 240 75.4/125 98/161 34.9/22.3 307 1.1 4.3 1.1 110 170 350 540 140 191 185 226 300 60.1/100 80/130 43.8/28.0 336 1.2 4.3 1.2 107 166 340 530 126 163 174 203 400 470/77.8 64/102 57.3/36.6 370 1.3 5.8 1.3 100 160 320 510 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 406 1.4 5.8 1.4 97 154 310 490 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 449 1.5 5.8 1.5 94 151 300 480 97 110 151 160

slide 22:

Caledonian Medium V oltage Cables Single Core 19/33KV Um36KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 50 8.0 16 2.0 34.2 1580 1270 6.7 1.2 2.0 2.2 41.0 2300 1980 70 8.0 16 2.0 35.8 1820 1380 7.1 1.2 2.0 2.2 42.6 2560 2120 95 8.0 16 2.1 37.6 2120 1510 7.5 1.2 2.0 2.3 44.4 2890 2290 120 8.0 16 2.1 39.0 2400 1630 7.9 1.2 2.0 2.3 45.8 3200 2430 150 8.0 25 2.2 40.9 2740 1810 8.2 1.3 2.5 2.4 48.9 3760 2830 185 8.0 25 2.2 42.4 3110 1950 8.6 1.3 2.5 2.5 50.6 4180 3010 240 8.0 25 2.3 45.1 3720 2180 9.2 1.3 2.5 2.5 53.1 4830 3270 300 8.0 25 2.4 47.3 4350 2460 9.7 1.4 2.5 2.6 55.5 5540 3630 400 8.0 35 2.5 51.2 5410 2880 10.3 1.4 2.5 2.7 59.4 6680 4130 500 8.0 35 2.6 53.8 6420 3320 11.0 1.5 2.5 2.8 62.2 7790 4690 630 8.0 35 2.7 59.0 7800 3780 11.8 1.5 2.5 2.9 67.4 9290 5220 Electrical Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m µΩ/m nH/m nH/m µΩ/m µΩ/m 50 387/641 494/822 6.8/4.4 138 0.83 2.6 1.0 151 214 480 680 511 834 527 844 70 268/443 343/568 9.8/6.3 154 0.92 2.6 1.0 144 201 460 640 364 583 386 597 95 193/320 248/410 13.3/8.5 169 1.01 2.6 1.1 138 195 440 620 272 427 300 446 120 153/253 196/325 17.2/11.0 183 1.10 2.6 1.1 132 188 420 600 225 345 257 367 150 124/206 159/265 21.2/13.5 194 1.16 4.3 1.2 126 182 400 580 193 287 229 313 185 99.1/164 128/211 26.6/17.0 210 1.26 4.3 1.2 122 182 390 580 165 237 206 267 240 75.4/125 98/161 34.9/22.3 229 1.37 4.3 1.3 119 176 380 560 140 191 185 226 300 60.1/100 80/130 43.8/28.0 249 1.49 4.3 1.4 113 173 360 550 126 163 174 203 400 47/77.8 64/102 57.3/36.6 273 1.64 5.8 1.5 107 163 340 520 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 298 1.79 5.8 1.6 104 163 330 520 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 327 1.96 5.8 1.7 100 160 320 510 97 110 151 160

slide 23:

21 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Current Rating for 3.8/6.6KV Um7.2KV 6.35/11KV Um12KV 8.7/15KV Um17.5KV Nom. Cross- Section Area Ground Duct Air Trefoil Unarm’d/Arm’d Flat Spaced Unarm’d/Arm’d Trefoil Unarm’d/Arm’d Flat Touching Unarm’d/Arm’d Trefoil Unarm’d/Arm’d Flat Spaced Unarm’d/Arm’d CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A 25 160/160 120/120 170/170 125/125 165/165 125/125 165/165 125/125 170/170 130/130 230/235 180/180 35 180/180 150/150 190/190 155/15 185/185 155/155 185/185 155/155 200/200 160/160 260/265 210/210 50 220/220 170/170 230/230 175/175 225/220 175/170 220/220 170/170 235/250 180/195 295/300 230/230 70 270/270 210.210 280/280 215/215 270/260 215/210 270/270 210/210 285/310 225/240 370/370 290/290 95 320/320 250/250 335/335 260/260 320/305 255/245 325/325 250/250 360/375 280/295 455/460 350/355 120 360/360 280/280 380/380 295/295 360/340 285/275 370/370 285/285 415/430 320/355 520/530 410/410 150 410/410 320/315 430/430 330/330 400/375 315/300 415/410 320/320 470/490 365/380 600/600 465/465 185 460/455 360/355 485/485 375/375 440/410 350/335 465/460 360/360 540/550 425/435 690/690 530/530 240 530/520 415/405 560/560 440/440 505/460 405/380 540/540 420/420 640/650 500/510 820/820 640/630 300 600/580 475/455 640/640 495/495 560/500 455/420 610/610 475/470 740/740 580/580 940/940 730/730 400 680/650 540/510 730/730 570/570 610/530 510/455 690/690 540/540 840/840 670/670 1100/1100 860/860 500 750/710 610/570 830/830 650/650 680/570 570/500 790/780 620/620 940/930 790/770 1280/12801010/1010 630 830/760 680/640 940/940 750/750 750/620 640/550 890/890 710/700 1110/1040 910/880 1500/1480 1190/1180 Current Rating for 12.7/22KV Um24KV Nom. Cross- Section Area Ground Duct Air Trefoil Unarm’d/Arm’d Flat Spaced Unarm’d/Arm’d Trefoil Unarm’d/Arm’d Flat Touching Unarm’d/Arm’d Trefoil Unarm’d/Arm’d Flat Spaced Unarm’d/Arm’d CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A 35 180/180 130/130 200/200 135/135 180/170 130/125 180/175 130/125 190/175 145/135 225/230 175/175 50 220/220 170/170 230/230 175/175 225/210 175/170 225/220 175/170 245/260 190/200 295/300 230/230 70 270/270 210.210 280/280 215/215 270/260 210/205 270/270 210/210 300/320 235/245 365/370 285/285 95 320/320 250/245 335/335 260/260 320/300 250/245 320/325 250/250 360/380 280/295 450/450 345/350 120 360/360 280/280 380/380 295/295 360/340 280/275 365/365 285/285 425/440 330/340 520/520 400/400 150 410/410 320/310 430/430 330/330 405/370 320/300 410/410 320/315 485/490 375/385 590/590 455/455 185 460/450 360/350 485/485 375/375 445/400 350/335 460/460 360/360 550/560 430/440 670/670 520/520 240 530/510 415/405 560/560 440/440 520/450 415/380 530/530 415/415 650/650 510/510 800/800 620/620 300 600/570 475/450 640/640 495/495 570/490 460/415 600/600 470/470 740/730 580/580 920/910 710/710 400 690/640 550/510 730/730 570/570 630/530 520/460 690/680 540/530 850/830 680/670 1070/1060 840/830 500 760/700 610/570 830/830 650/650 700/570 570/510 780/770 610/610 980/940 790/770 1250/1230 980/970 630 850/760 690/640 950/940 750/750 780/610 650/560 890/880 700/700 1130/1050 920/880 1450/1430 1060/1140

slide 24:

Caledonian Medium V oltage Cables Current Rating for 19/33KV Um36KV Nom. Cross- Section Area Ground Duct Air Trefoil Unarm’d/Arm’d Flat Spaced Unarm’d/Arm’d Trefoil Unarm’d/Arm’d Flat Touching Unarm’d/Arm’d Trefoil Unarm’d/Arm’d Flat Spaced Unarm’d/Arm’d CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A 50 220/220 170/170 230/230 175/175 225/220 175/170 225/220 175/170 245/260 190/200 295/300 230/230 70 270/270 210.210 280/280 215/215 270/260 210/205 270/270 210/210 300/320 235/245 365/370 285/285 95 320/320 250/245 335/335 260/260 320/300 250/245 320/325 250/250 360/380 280/295 450/450 345/350 120 360/360 280/280 380/380 295/295 360/340 280/275 365/365 285/285 425/440 330/340 520/520 400/400 150 410/410 320/310 430/430 330/330 405/370 320/300 410/410 320/315 485/490 375/385 590/590 455/455 185 460/450 360/350 485/485 375/375 445/400 350/335 460/460 360/360 550/560 430/440 670/670 520/520 240 530/510 415/405 560/560 440/440 520/450 415/380 530/530 415/415 650/650 510/510 800/800 620/620 300 600/570 475/450 640/640 495/495 570/490 460/415 600/600 470/470 740/730 580/580 920/910 710/710 400 690/640 550/510 730/730 570/570 630/530 520/460 690/680 540/530 850/830 680/670 1070/1060 840/830 500 760/700 610/570 830/830 650/650 700/570 570/510 780/770 610/610 980/940 790/770 1250/1230 980/970 630 850/760 690/640 940/940 750/750 780/610 650/560 890/880 700/700 1130/1050 920/880 1450/1430 1060/1140 ▓ Current Rating Conditions: Ground Temperature: 20°C Ambient Temperature air: 30°C Depth of Soil: 0.8m Thermal Resistance of Soil: 1.5K•m/W

slide 25:

23 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Three Core Cables to BS 6622/BS 7835 ▓ APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations indoors and in cable ducts outdoors underground and in water as well as for installation on cable trays for industries switchboards and power stations. ▓ STANDARD: BS 6622 BS 7835 LSZH Version ▓ CONSTRUCTION: Conductor: Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded class 2 and aluminium conductors shall be either solid or stranded class 2. Conductor Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm and the maximum resistivity shall not exceed 500 Ohm-m at 90°C. Insulation: Insulation is of cross-linked polyethylene compound XLPE GP8 conforming to BS 7655-1.3 or EPR GP7 conforming to BS 7655-1.2. Table 1. Insulation Thickness Nom. Cross Section Area Insulation Thickness at Nom. Voltage 3.8/6.6KVUm7.2KV 6.35/11KVUm12KV 8.7/15KVUm17.5KV 12.7/22KVUm24KV 19/33KVUm36KV mm² mm mm mm mm mm 70 – 185 2.5 3.4 4.5 5.5 8.0 240 2.6 3.4 4.5 5.5 8.0 300 2.8 3.4 4.5 5.5 8.0 400 3.0 3.4 4.5 5.5 8.0 Above 500 3.2 3.4 4.5 5.5 8.0 PVC/PE/LSZH Over Sheath PVC/PE/LSZH Separation Sheath optional Armour optional Binder Conductor Screen Conductor XLPE/EPR Insulation Insulation Screen Metallic Screen

slide 26:

Caledonian Medium V oltage Cables Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly ftted to the insulation to exclude all air voids and can be easily hand stripped on site. Inner Covering Fillers: For cables with a collective metallic layer or cables with a metallic layer over each individual cores with additional collective metallic layers semi-conducting inner covering and fllers shall be applied over the laid up cores. The inner covering is made of non hygroscopic material except if the cable is to be made longitudinally watertight. The inner covering shall be extruded or lapped. The approximate thickness of extruded inner coverings is given in Table 2: Table 2. Approximate Thickness of Extruded Inner Coverings Ficititous Diameter over Laid Up Cores Approx. Thickress of Extruded Inner Covering mm mm 35 45 1.0 25 35 1.2 35 45 1.4 45 60 1.6 60 80 1.8 80 - 2.0 The approximate thickness of lapped inner coverings shall be 0.6mm. Metallic Layer: The metallic layer shall be applied over each core or applied as a collective screen. The metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The metallic layer provides an earth fault current path capable of withstanding fault current to earth of 1000A for one second at maximum temperature 160°C. Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires copper tape with minimum thickness of 0.1mm can be applied helically with overlap. Total cross section of copper wire screen is shown in table 3. Table 3. Minimum Total Cross Section of Copper Wire Screen DC Resistance of The Screen Nominal Cross-Section Area of Cable Minimum Cross-Section of Copper Wire Screen Area DC Resistance of the Copper Wire Screen mm² mm² mm up to 120 16 1.06 150-300 25 0.72 400-630 35 0.51 Separation Sheath for armoured cable: The separation sheath comprises a layer of extruded PVC PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where

slide 27:

25 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Du is the fctitious diameter under the sheath in mm. The nominal separation sheath thickness shall not be less than 1.2mm. Armour for armoured cable: The armour consists of galvanized steel wire applied over the inner covering with diameter specifed as in Table 4. Table 4. Armour Wire Diameter Fictitiious Diameter under the Armour Armour Wire Diameter mm mm 25 1.6 25 35 2.0 35 60 2.5 60 - 3.15 Over Sheath: Overall sheath comprises a layer of extruded either PVC type 9 conforming to BS 7665-4.2 or MDPE type TS2 conforming to BS 7655-10.1 LSZH can be offered as an option. The over sheath is normally black in colour. When a DC voltage test is to be performed on the over sheath a semi-conducting layer such as graphite coating shall be applied over the surface of the extruded over sheath. The nominal over sheath thickness is calculated by 0.035+D where D is the diameter immediately under the over sheath in mm. For cables with the over sheath not applied over the armour the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour the nominal over sheath thickness shall not be less than 1.8mm. ▓ PHYSICAL PROPERTIES: Operating Temperature: up to 90°C Temperature Range: -5°C PVC or LSZH sheath -20°C PE sheath Short Circuit Temperature: 250°C short circuit duration up to 5 seconds Bending Radius: 15 x OD Table 5. Nominal /Operating /Test Voltages Rated Voltage Uo/U Operating Voltage Um Testing Voltage rms 3.8/6.6KV 7.2KV 15KV 6.35/11KV 12KV 25.5KV 8.7/15KV 17.5KV 35KV 12.7/22KV 24KV 51KV 19/33KV 36KV 76KV

slide 28:

Caledonian Medium V oltage Cables Three Core 3.8/6.6KV Um7.2KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 25 2.5 16 2.1 37.7 2205 1740 3.4 1.2 2.0 2.2 44.5 3890 3465 35 2.5 16 2.3 41.2 2690 2010 3.6 1.2 2.5 2.3 46.8 4420 3730 50 2.5 16 2.5 44.9 3340 2350 3.8 1.3 2.5 2.5 51.5 5640 4690 70 2.5 16 2.6 48.0 4050 2730 4.3 1.3 2.5 2.6 55.0 6570 5240 95 2.5 16 2.7 51.7 5000 3180 4.7 1.4 2.5 2.7 58.9 7760 5890 120 2.5 16 2.8 54.7 5890 3590 5.0 1.5 2.5 2.8 62.1 8810 6510 150 2.5 25 2.9 58.4 6960 4160 5.3 1.5 2.5 2.9 65.8 10110 7310 185 2.5 25 3.0 61.9 8160 4650 5.8 1.6 2.5 3.0 69.5 11520 7960 240 2.6 25 3.2 68.1 10210 5530 6.3 1.7 2.5 3.2 75.9 13920 9140 300 2.8 25 3.5 73.6 12380 6670 7.0 1.8 3.15 3.5 83.1 17400 11620 400 3.0 35 3.7 83.8 16190 8430 7.7 2.0 3.15 3.7 93.0 21900 13980 Electrical Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Current Ratings D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reac- tance Induc- tance Ground Duct Air CU AL CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m A A A 25 727/1200 927/1538 3.6/2.3 272 0.33 2.6 0.4 113 370 140 115 125 95 145 115 35 524/868 668/1113 5.0/3.2 301 0.36 2.6 0.5 108 350 170 135 150 115 175 140 50 387/641 494/822 6.8/4.4 332 0.40 2.6 0.5 102 330 210 160 180 135 220 170 70 268/443 343/568 9.8/6.3 383 0.46 2.6 0.6 97 310 255 195 215 165 270 210 95 193/320 248/410 13.3/8.5 432 0.52 2.6 0.6 92 290 300 230 255 200 330 250 120 153/253 196/325 17.2/11.0 474 0.57 2.6 0.7 89 280 340 265 290 225 375 295 150 124/206 159/265 21.2/13.5 511 0.61 4.3 0.7 87 280 380 295 330 255 430 330 185 99.1/164 128/211 26.6/17.0 562 0.67 4.3 0.8 86 270 430 335 370 290 490 385 240 75.4/125 98/161 34.9/22.3 602 0.72 4.3 0.9 83 260 490 380 425 335 570 450 300 60.1/100 80/130 43.8/28.0 622 0.75 4.3 1.0 82 260 540 435 470 375 650 510 400 47.0/77.8 64/102 57.3/36.6 648 0.78 5.8 1.1 80 250 590 480 520 420 700 570

slide 29:

27 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Three Core 6.35/11KV Um12KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 25 3.4 16 2.3 42.8 2600 2120 3.8 1.3 2.5 2.4 50.0 4930 4400 35 3.4 16 2.3 45.3 3000 2320 4.1 1.3 2.5 2.5 52.3 5380 4700 50 3.4 16 2.4 48.5 3630 2690 4.4 1.4 2.5 2.6 55.7 6210 5260 70 3.4 16 2.5 52.0 4440 3110 4.7 1.4 2.5 2.7 59.2 7200 5870 95 3.4 16 2.7 56.0 5440 3620 5.2 1.5 2.5 2.8 63.2 8420 6550 120 3.4 16 2.8 59.4 6370 4020 5.5 1.6 2.5 3.0 67.0 9580 7190 150 3.4 25 2.9 62.7 7430 4630 5.8 1.6 2.5 3.1 70.3 10830 8030 185 3.4 25 3.0 66.1 8680 5150 6.2 1.7 2.5 3.2 73.9 12290 8720 240 3.4 25 3.1 71.7 10690 5990 6.8 1.8 3.15 3.4 81.2 15620 10790 300 3.4 25 3.3 76.4 12770 7050 7.3 1.9 3.15 3.6 86.1 18030 12240 400 3.4 35 3.5 85.1 16460 8680 8.0 2.0 3.15 3.8 95.0 22350 14350 Electrical Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Current Ratings D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reac- tance Induc- tance Ground Duct Air CU AL CU AL CU AL mm² µ Ω/m µ Ω/m kA pF/m mA/m kA kA µΩ/m nH/m A A A 25 727/1200 927/1538 3.6/2.3 216 0.43 2.6 0.5 123 390 140 115 125 95 145 115 35 524/868 668/1113 5.0/3.2 237 0.47 2.6 0.6 115 370 170 135 150 115 175 140 50 387/641 494/822 6.8/4.4 260 0.52 2.6 0.6 109 350 210 160 180 135 220 170 70 268/443 343/568 9.8/6.3 298 0.60 2.6 0.7 103 330 255 195 215 165 270 210 95 193/320 248/410 13.3/8.5 334 0.67 2.6 0.7 99 310 300 230 255 200 330 250 120 153/253 196/325 17.2/11.0 365 0.73 2.6 0.8 96 310 340 265 290 225 375 295 150 124/206 159/265 21.2/13.5 392 0.78 4.3 0.8 93 300 380 295 330 255 430 330 185 99.1/164 128/211 26.6/17.0 430 0.86 4.3 0.9 90 290 430 335 370 290 490 385 240 75.4/125 98/161 34.9/22.3 476 0.95 4.3 0.9 87 280 490 380 425 335 570 450 300 60.1/100 80/130 43.8/28.0 524 1.05 4.3 1.0 85 270 540 435 470 375 650 510 400 47.0/77.8 64/102 57.3/36.6 580 1.16 5.8 1.1 81 260 590 480 520 420 700 570

slide 30:

Caledonian Medium V oltage Cables Three Core 8.7/15KV Um17.5KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 25 4.5 16 2.4 48.4 3000 2420 4.4 1.4 2.5 2.6 55.2 5600 5100 35 4.5 16 2.5 50.4 3450 2670 4.7 1.4 2.5 2.7 57.6 6130 5440 50 4.5 16 2.6 53.7 4140 3190 4.9 1.5 2.5 2.8 61.1 7010 6060 70 4.5 16 2.7 57.2 4980 3640 5.3 1.5 2.5 2.9 64.6 8030 6700 95 4.5 16 2.8 60.6 5900 4050 5.7 1.6 2.5 3.0 68.2 9160 7330 120 4.5 16 2.9 63.9 6870 4560 6.1 1.7 2.5 3.1 71.7 10340 8030 150 4.5 25 3.0 67.9 8030 5230 6.4 1.7 2.5 3.2 75.4 11730 8930 185 4.5 25 3.1 71.1 9310 5770 6.8 1.8 3.15 3.4 80.6 14170 10570 240 4.5 25 3.3 76.9 11390 6680 7.4 1.9 3.15 3.6 86.6 16670 11810 300 4.5 25 3.5 81.6 13510 7790 7.9 2.0 3.15 3.7 91.3 19140 13340 400 4.5 35 3.7 89.9 17130 9340 8.5 2.1 3.15 4.0 100.0 23360 15410 Electrical Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Current Ratings D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reac- tance Induc- tance Ground Duct Air CU AL CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m A A A 25 727/1200 927/1538 3.6/2.3 176 0.48 2.6 0.6 138 410 140 115 125 95 145 115 35 524/868 668/1113 5.0/3.2 193 0.53 2.6 0.6 123 390 170 135 150 115 175 140 50 387/641 494/822 6.8/4.4 211 0.58 2.6 0.7 116 370 210 160 180 135 220 170 70 268/443 343/568 9.8/6.3 240 0.65 2.6 0.7 110 350 255 195 215 165 270 210 95 193/320 248/410 13.3/8.5 267 0.73 2.6 0.8 105 330 300 230 255 200 330 250 120 153/253 196//325 17.2/11.0 291 0.79 2.6 0.8 102 320 340 265 290 225 375 295 150 124/206 159/265 21.2/13.5 312 0.85 4.3 0.9 98 310 380 300 330 255 430 330 185 99.1/164 128/211 26.6/17.0 340 0.93 4.3 0.9 95 300 430 335 370 290 490 385 240 75.4/125 98/161 34.9/22.3 375 1.02 4.3 1.0 91 290 490 380 425 335 570 450 300 60.1/100 80/130 43.8/28.0 411 1.12 4.3 1.1 89 280 540 435 470 375 650 510 400 47.0/77.8 64/102 57.3/36.6 454 1.24 5.8 1.2 84 270 590 480 520 420 700 570

slide 31:

29 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to BS 6622/BS 7835 Three Core 12.7/22KV Um24KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 35 5.5 16 2.7 51 3750 2880 5.2 1.5 2.5 2.8 62.3 6870 6140 50 5.5 16 2.8 54 4240 3250 5.4 1.5 2.5 2.9 65.6 7710 6810 70 5.5 16 2.9 58 5050 3650 5.9 1.6 2.5 3.0 69.0 8710 7370 95 5.5 16 3.0 62 6010 4110 6.2 1.7 2.5 3.2 73.1 10000 8130 120 5.5 16 3.1 65 6990 4660 6.6 1.7 3.15 3.3 77.7 12040 9730 150 5.5 25 3.2 68 8130 5330 6.9 1.8 3.15 3.4 81.7 13550 10750 185 5.5 25 3.3 72 9410 5870 7.4 1.9 3.15 3.6 85.5 15150 11610 240 5.5 25 3.5 79 11490 6880 7.8 2.0 3.15 3.7 91.3 17710 12840 300 5.5 25 3.7 84 13710 7890 8.2 2.0 3.15 3.9 96.0 20170 14360 400 5.5 35 3.9 91 17230 9440 9.0 2.2 3.15 4.1 104.8 24520 16480 Electrical Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Current Ratings D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reac- tance Induc- tance Ground Duct Air CU AL CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m A A A 35 524/868 668/1113 5.0/3.2 168 0.67 2.6 0.7 129 410 170 135 155 120 180 145 50 387/641 494/822 6.8/4.4 183 0.73 2.6 0.8 122 390 210 160 185 140 225 175 70 268/443 343/568 9.8/6.3 207 0.83 2.6 0.8 115 370 255 195 225 170 275 215 95 193/320 248/410 13.3/8.5 229 0.92 2.6 0.9 110 350 295 230 260 205 330 260 120 153/253 196/325 17.2/11.0 249 1.00 2.6 0.9 106 340 335 260 300 235 380 300 150 124/206 159/265 21.2/13.5 266 1.06 4.3 1.0 103 330 375 290 335 265 430 335 185 99.1/164 128/211 26.6/17.0 289 1.16 4.3 1.0 100 320 420 330 380 300 490 390 240 75.4/125 98/161 34.9/22.3 318 1.27 4.3 1.1 95 300 480 380 430 345 570 460 300 60.1/100 80/130 43.8/28.0 348 1.39 4.3 1.2 93 300 530 425 480 385 650 520 400 47.0/77.8 64/102 57.3/36.6 383 1.53 5.8 1.3 87 280 590 480 520 420 700 570

slide 32:

Caledonian Medium V oltage Cables Three Core 19/33KV Um36KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Nom. Insulation Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thickness Nom. Armour Wire Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm² mm mm kg/km mm² mm mm mm mm kg/km 35 8.0 16 3.1 60 3750 2880 6.5 1.7 2.5 3.2 74.9 9460 8700 50 8.0 16 3.2 65 5240 4260 6.7 1.8 3.15 3.4 79.0 10620 9680 70 8.0 16 3.3 70 6120 4730 7.1 1.8 3.15 3.5 82.5 11840 10440 95 8.0 16 3.4 74 7140 5240 7.5 1.9 3.15 3.6 86.4 13200 11350 120 8.0 16 3.5 77 8080 5710 7.9 2.0 3.15 3.7 89.9 14520 12190 150 8.0 25 3.6 80 9120 6220 8.2 2.0 3.15 3.8 93.6 16070 13280 185 8.0 25 3.7 84 10440 6940 8.6 2.1 3.15 3.9 97.3 17710 14090 240 8.0 25 3.9 91 12620 8010 9.2 2.2 3.15 4.1 103.2 20370 15460 300 8.0 25 4.0 95 14690 8800 9.7 2.3 3.15 4.3 108.2 22980 17210 400 8.0 35 4.3 103 17720 10230 10.3 2.4 3.15 4.5 116.8 27480 19450 Electrical Data Nom. Cross- Section Area Unarmored Cables Aluminium Wire Armoured Cables Current Ratings D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reac- tance Induc- tance Ground Duct Air CU AL CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m A A A 35 524/868 668/1113 5.0/3.2 132 0.79 2.6 0.9 140 460 170 135 155 120 180 145 50 387/641 494/822 6.8/4.4 142 0.85 2.6 1.0 134 430 210 160 185 140 225 175 70 268/443 343/568 9.8/6.3 159 0.95 2.6 1.0 127 400 255 195 225 170 275 215 95 193/320 248/410 13.3/8.5 175 1.05 2.6 1.1 121 390 295 230 260 205 330 260 120 153/253 196/325 17.2/11.0 189 1.13 2.6 1.1 117 370 335 260 300 235 380 300 150 124/206 159/265 21.2/13.5 201 1.21 4.3 1.2 113 360 375 290 335 265 430 335 185 99.1/164 128/211 26.6/17.0 217 1.30 4.3 1.2 109 350 420 330 380 300 490 390 240 75.4/125 98/161 34.9/22.3 237 1.42 4.3 1.3 104 330 480 380 430 345 570 460 300 60.1/100 80/130 43.8/28.0 258 1.55 4.3 1.4 101 320 530 425 480 385 650 520 400 47.0/77.8 64/102 57.3/36.6 282 1.69 5.8 1.5 96 290 590 480 520 420 700 570

slide 33:

III I II III IV V Medium Voltage Cables to IEC 60502 Single Core Cables to IEC 60502 Three Core Cables to IEC 60502 Caledonian Medium Voltage Cables

slide 34:

Caledonian Medium V oltage Cables Single Core Cables to IEC 60502 ▓ APPLICATIONS: The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations indoors and in cable ducts outdoors underground and in water as well as for installation on cable trays for industries switchboards and power stations. ▓ STANDARD: IEC 60502 Part 11.8/3KV IEC 60502 Part 23.6/6KV to 18/30KV ▓ CONSTRUCTION: Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. Conductor Screen: The conductor screen consists of an extruded layer of non metallic semi-conducting compound firmly bonded to the insulation to exclude all air voids. The conductor screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3KV and 3.6/6KV cables. Insulation: Insulation is of polyvinyl chloride PVC intended for 1.8/3KV and 3.6/6KV cables cross-linked polyethylene compound XLPE or ethylene propylene rubber EPR/HEPR. Table 1. Insulation Thickness of XLPE or EPR/HEPR Insulation Nom. Cross Section Area Insulation Thickness at Nominal V oltage 1.8/3KV Um3.6KV 3.6/6KV Um7.2KV 6/10KV Um12KV 8.7/15KV Um17.5KV 12/20KV Um24KV 18/30KV Um36KV 21/35KV Um42KV 26/35KV Um42KV mm² mm mm mm mm mm mm mm mm XLPE/EPR XLPE EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR Unscreened Screened 10 2.0 2.5 3.0 2.5 - - - - - - 16 2.0 2.5 3.0 2.5 3.4 - - - - - 25 2.0 2.5 3.0 2.5 3.4 4.5 - - - - 35 2.0 2.5 3.0 2.5 3.4 4.5 5.5 - - - 50 – 185 2.0 2.5 3.0 2.5 3.4 4.5 5.5 8.0 9.3 10.5 240 2.0 2.6 3.0 2.6 3.4 4.5 5.5 8.0 9.3 10.5 300 2.0 2.8 3.0 2.8 3.4 4.5 5.5 8.0 9.3 10.5 400 2.0 3.0 3.0 3.0 3.4 4.5 5.5 8.0 9.3 10.5 500 - 1600 2.2-2.8 3.2 3.2 3.2 3.4 4.5 5.5 8.0 9.3 10.5 Insulation Thickness of PVC is 3.4mm 1- 1600mm sq for 3.6/6KV cables. PVC/PE/LSZH Over Sheath Aluminium Wire Armour optional XLPE/EPR/HEPR Insulation Conductor Conductor Screen Insulation Screen Metallic Screen PVC/PE/LSZH Separation Sheath optional Binder

slide 35:

33 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Insulaton Screen: The insulation screen consists of an extruded layer of non metallic semi- conducting compound extruded over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly ftted to the insulation to exclude all air voids and can be easily hand stripped on site. The insulation screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3KV and 3.6/6KV cables. The screen may be covered by semi-conductive water blocking swellable tape to ensure longitudinal watertightness. Metallic Layer: The metallic layer may be applied over the individual cores or the core assembly collectively. The following types of metallic layers are provided: 1 Metallic Screen 2 Concentric Conductor 3 Metallic Sheath 4 Metallic armour The metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires to provide an earth fault current path. The concentric conductor is applied directly either over the insulation or over the insulation screen or over an inner covering. The metallic sheath consists of lead or lead alloy applied as a tightly ftting seamless tube. The metallic armour consists of either fat wire armour round wire armour and double tape armour. Table 2. Minimum Total Cross Section of Metallic Screen Nom. Cross-Section Area of Cable Min. Cross-Section of Metallic Screen DC Resistance of the Copper Wire Screen mm² mm² mm up to 120 16 1.06 150-300 25 0.72 400-630 35 0.51 800-1000 50 0.35 Separation Sheath for armoured cable: The separation sheath comprises a layer of extruded PVC PE or LSZH applied under the armour. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fctitious diameter under the sheath in mm. For cables without a lead sheath the nominal separation sheath thickness shall not be less than 1.2mm. For cables where the separation sheath is applied over the lead sheath the nominal separation sheath thickness shall not be less than 1.0mm. Lapped Bedding for armoured lead sheathed cable: The lapped bedding consists of either impregnated/synthetic compounded paper tapes or a combination of two layers of these paper tapes followed by a few layers of compounded fabulous materials. The thickness is around 1.5mm. Armour for armoured cable: The armour consists of round aluminium wire armour applied helically over an extruded separation sheath. Table 3. Round Armour Wire Diameter

slide 36:

Caledonian Medium V oltage Cables Fictitious Diameter under the Armour Armour Wire Diameter mm mm - 10 0.8 10 15 1.25 15 25 1.6 25 35 2.0 35 60 2.5 60 - 3.15 Over Sheath: Overall sheath comprises a layer of extruded thermoplastic compound PVC PE or LSZH can be offered as an option. or elastomeric compound polychlorprene CSP or chlorosulfonated PE. The nominal over sheath thickness is calculated by 0.035D+1 where D is the fctitiuous diameter immediately under the over sheath in mm. For unarmoured cables and cables with the over sheath not applied over the armour metallic screen or concentric conductor the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour metallic screen or concentric conductor the nominal over sheath thickness shall not be less than 1.8mm. ▓ PHYSICAL PROPERTIES: Operating Temperature: up to 70°C PVC insulation up to 90°C XLPE or EPR insulation Temperature Range: -5°C PVC or LSZH sheath -20°C PE sheath Short Circuit Temperature 5 seconds maximum duration : 140-160°C PVC insulation 250°C XLPE or EPR insulation Bending Radius: 12 x OD Table 4. Nominal /Operating /Testing Voltages Rated Voltage Uo/U Operating Voltage Um Testing Voltage rms 1.8/3KV 3.6KV 6.5KV 3.6/6KV 7.2KV 12.5KV 6/10KV 12KV 21KV 8.7/15KV 17.5KV 30.5KV 12/20KV 24KV 42KV 18/30KV 36KV 63KV 21/35KV 42KV 73.553KV 26/35KV 42KV 9165KV 21/35KV and 26/35KV power frequency voltage test can be made under the following conditions: 2.5Uo x 30mins or 3.0Uo x 15mins. Numbers in brackets refer to the test values for 3.0Uo x 1.5mins.

slide 37:

35 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Single Core 1.8/3KV Um3.6KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Steel Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 10 2.0 0.1 16 1.8 13 240 180 1.2 1.6 1.8 18 460 400 16 2.0 0.1 16 1.8 13 300 200 1.2 1.6 1.8 19 530 430 25 2.0 0.1 16 1.8 15 410 250 1.2 1.6 1.8 20 650 500 35 2.0 0.1 16 1.8 16 510 300 1.2 1.6 1.8 21 780 560 50 2.0 0.1 16 1.8 17 640 350 1.2 1.6 1.8 22 930 640 70 2.0 0.1 16 1.8 19 850 440 1.2 1.6 1.8 24 1170 750 95 2.0 0.1 16 1.8 20 1130 540 1.2 1.6 1.8 26 1460 870 120 2.0 0.1 16 1.8 22 1370 630 1.2 1.6 1.8 27 1730 990 150 2.0 0.1 25 1.8 23 1650 730 1.2 1.6 1.8 29 2030 1110 185 2.0 0.1 25 1.8 25 2010 860 1.2 1.6 1.9 30 2430 1280 240 2.0 0.1 25 1.8 27 2570 1050 1.2 1.6 2.0 33 3040 1530 300 2.0 0.1 25 1.8 29 3160 1250 1.2 2.0 2.1 36 3760 1860 400 2.0 0.1 35 1.9 33 3980 1560 1.2 2.0 2.2 39 4660 2230 500 2.2 0.1 35 2.1 35.5 4910 1905 1.3 2.5 2.5 43 5930 2930 630 2.4 0.1 35 2.2 39.7 6340 2420 1.4 2.5 2.6 49 7370 3430 800 2.6 0.1 50 2.3 44.5 7890 2980 1.4 2.5 2.7 52 9070 4230 1000 2.8 0.1 50 2.5 49.4 9890 3700 1.5 2.5 2.9 56 11100 4950 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/ m 10 1830/3080 2330/3920 1.4/0.9 182 0.27 2.6 0.2 151 201 384 558 2332 3846 2332 3840 16 1150/1910 1460/2420 2.2/1.4 201 0.29 2.6 0.3 140 193 362 546 1462 2411 1478 2420 25 727/1200 927/1538 3.6/2.3 222 0.32 2.6 0.3 131 185 345 535 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 251 0.35 2.6 0.4 122 178 327 524 679 1121 695 1131 50 387/641 494/822 6.8/4.4 281 0.39 2.6 0.4 116 172 313 514 511 834 527 844 70 268/443 343/568 9.8/6.3 341 0.45 2.6 0.5 110 165 300 495 364 583 386 597 95 193/320 248/410 13.3/8.5 397 0.50 2.6 0.5 104 160 287 485 272 427 300 446 120 153/253 196/325 17.2/11.0 430 0.55 2.6 0.6 104 159 283 480 225 345 257 367 150 124/206 159/266 21.2/13.5 464 0.59 4.3 0.6 100 156 280 475 193 287 229 313 185 99.1/164 128/211 26.6/17.0 513 0.65 4.3 0.7 98 154 274 465 165 237 206 267 240 75.4/125 98/161 34.9/22.3 573 0.70 4.3 0.9 94 150 267 459 140 191 185 226 300 60.1/100 80/130 43.8/28.0 652 0.72 4.3 1.0 91 147 260 455 128 163 174 203 400 47.0/77.8 64/102 57.3/36.6 727 0.75 5.8 1.1 90 147 253 445 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 754 0.79 5.8 1.2 89 145 248 435 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 786 0.87 5.8 1.3 86 143 245 425 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 846 0.91 8.2 1.4 85 142 243 415 92 101 147 153 1000 17.6/29.1 30/46 143.0/94.0 916 0.99 8.2 1.5 83 141 239 405 88 95 144 148

slide 38:

Caledonian Medium V oltage Cables Single Core 3.6/6KV Um7.2KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 10 2.5 0.1 16 1.8 16 320 260 1.2 1.6 1.8 22 610 550 16 2.5 0.1 16 1.8 16 390 290 1.2 1.6 1.8 22 680 580 25 2.5 0.1 16 1.8 18 500 340 1.2 1.6 1.8 23 810 660 35 2.5 0.1 16 1.8 19 610 400 1.2 1.6 1.8 24 940 730 50 2.5 0.1 16 1.8 20 750 450 1.2 1.6 1.8 26 1100 810 70 2.5 0.1 16 1.8 22 970 550 1.2 1.6 1.8 27 1350 930 95 2.5 0.1 16 1.8 23 1250 660 1.2 1.6 1.9 29 1670 1080 120 2.5 0.1 16 1.8 25 1500 760 1.2 1.6 1.9 31 1950 1200 150 2.5 0.1 25 1.8 26 1790 860 1.2 1.6 2.0 32 2270 1350 185 2.5 0.1 25 1.8 28 2150 1000 1.2 2.0 2.1 35 2770 1620 240 2.6 0.1 25 1.9 31 2770 1250 1.2 2.0 2.2 38 3440 1930 300 2.8 0.1 25 2.0 34 3400 1500 1.2 2.0 2.2 41 4120 2210 400 3.0 0.1 35 2.1 38 4280 1850 1.3 2.5 2.4 46 5250 2820 500 3.2 0.1 35 2.1 41.5 5325 2240 1.4 2.5 2.6 50 6520 3520 630 3.2 0.1 35 2.2 45.3 6745 2750 1.5 2.5 2.7 56 7960 4020 800 3.2 0.1 50 2.4 49.9 8290 3310 1.5 2.5 2.8 59 9660 4820 1000 3.2 0.1 50 2.5 54.2 10255 3990 1.6 2.5 3.0 63 11690 5540 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 10 1830/3080 2330/3920 1.4/0.9 202 0.26 2.6 0.4 160 214 420 610 2332 3846 2345 3840 16 1150/1910 1460/2420 2.2/1.4 232 0.29 2.6 0.4 152 205 410 600 1462 2411 1478 2421 25 727/1200 927/1538 3.6/2.3 262 0.32 2.6 0.4 142 196 400 590 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 291 0.35 2.6 0.5 133 187 390 580 679 1121 695 1131 50 387/641 494/822 6.8/4.4 321 0.39 2.6 0.5 121 179 380 570 511 834 527 844 70 268/443 343/568 9.8/6.3 371 0.45 2.6 0.6 115 173 370 550 364 583 386 597 95 193/320 248/410 13.3/8.5 417 0.50 2.6 0.6 110 168 350 540 272 427 300 446 120 153/253 196/325 17.2/11.0 459 0.55 2.6 0.7 107 165 340 520 225 345 257 367 150 124/206 159/265 21.2/13.5 494 0.59 4.3 0.7 103 161 330 510 193 287 229 313 185 99.1/164 128/211 26.6/17.0 543 0.65 4.3 0.8 100 158 320 500 165 237 206 267 240 75.4/125 98/161 34.9/22.3 583 0.70 4.3 0.9 97 155 310 490 140 191 185 226 300 60.1/100 80/130 43.8/28.0 602 0.72 4.3 1.0 95 153 300 490 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 627 0.75 5.8 1.1 92 150 290 480 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 654 0.79 5.8 1.2 90 147 290 470 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 726 0.87 5.8 1.3 87 145 280 460 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 786 0.91 8.2 1.4 85 143 270 460 92 101 147 153 1000 17.6/29.1 30/46 143.0/94.0 856 0.99 8.2 1.5 83 141 260 450 88 95 144 148 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 39:

37 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Single Core 6/10KV Um12KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 16 3.4 0.1 16 1.8 18 450 350 1.2 1.6 1.8 24 770 670 25 3.4 0.1 16 1.8 20 560 400 1.2 1.6 1.8 25 910 750 35 3.4 0.1 16 1.8 21 680 460 1.2 1.6 1.8 26 1040 820 50 3.4 0.1 16 1.8 22 810 520 1.2 1.6 1.8 28 1190 900 70 3.4 0.1 16 1.8 24 1050 620 1.2 1.6 1.9 29 1470 1040 95 3.4 0.1 16 1.8 25 1320 730 1.2 1.6 2.0 31 1780 1190 120 3.4 0.1 16 1.8 27 1580 840 1.2 2.0 2.0 34 2150 1410 150 3.4 0.1 25 1.9 28 1880 960 1.2 2.0 2.1 35 2480 1560 185 3.4 0.1 25 1.9 30 2250 1100 1.2 2.0 2.1 37 2890 1730 240 3.4 0.1 25 2.0 33 2870 1350 1.2 2.0 2.2 40 3570 2050 300 3.4 0.1 25 2.1 35 3490 1580 1.2 2.0 2.3 42 4230 2330 400 3.4 0.1 35 2.2 39 4350 1920 1.3 2.5 2.4 47 5320 2890 500 3.4 0.1 35 2.2 39.9 5235 2240 1.4 2.5 2.5 51 6510 3530 630 3.4 0.1 35 2.3 43.7 6675 2765 1.5 2.5 2.6 56 7960 4050 800 3.4 0.1 50 2.5 48.6 8225 3330 1.5 2.5 2.7 59 9670 4850 1000 3.4 0.1 50 2.6 52.9 10210 4030 1.6 2.5 2.9 63 11710 5570 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 16 1150/1910 1460/2420 2.2/1.4 187 0.39 2.6 0.5 152 216 480 680 1462 2411 1478 2421 25 727/1200 927/1538 3.6/2.3 208 0.42 2.6 0.5 144 210 460 660 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 229 0.46 2.6 0.6 136 200 440 640 679 1121 695 1131 50 387/641 494/822 6.8/4.4 252 0.50 2.6 0.6 131 195 420 620 511 834 527 844 70 268/443 343/568 9.8/6.3 288 0.58 2.6 0.7 122 188 390 600 364 583 386 597 95 193/320 248/410 13.3/8.5 323 0.65 2.6 0.7 122 182 390 580 272 427 300 446 120 153/253 196/325 17.2/11.0 353 0.71 2.6 0.8 116 172 370 550 225 345 257 367 150 124/206 159/265 21.2/13.5 380 0.76 4.3 0.8 110 166 350 530 193 287 229 313 185 99.1/164 128/211 26.6/17.0 416 0.83 4.3 0.9 107 166 340 530 165 237 206 267 240 75.4/125 98/161 34.9/22.3 460 0.92 4.3 0.9 104 163 330 520 140 191 185 226 300 60.1/100 80/130 43.8/28.0 506 1.01 4.3 1.0 100 157 320 500 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 561 1.12 5.8 1.1 94 154 300 490 113 141 164 184 500 36.6/60.5 51/81.0 72.3/46.2 619 1.24 5.8 1.2 91 151 290 480 105 124 158 171 630 28.3/46.9 42/64.0 91.2/58.3 698 1.37 5.8 1.3 91 148 290 470 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 780 1.39 8.2 1.4 88 144 280 470 92 101 147 153 1000 17.6/29.1 30/46 143.0/94.0 860 1.54 8.2 1.5 85 143 270 460 88 95 144 148 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 40:

Caledonian Medium V oltage Cables Single Core 8.7/15KV Um17.5KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 25 4.5 0.1 16 1.8 22 640 480 1.2 1.6 1.8 28 1020 860 35 4.5 0.1 16 1.8 23 760 540 1.2 1.6 1.9 29 1170 950 50 4.5 0.1 16 1.8 24 900 610 1.2 1.6 1.9 30 1340 1040 70 4.5 0.1 16 1.8 26 1140 710 1.2 1.6 2.0 32 1610 1190 95 4.5 0.1 16 1.8 27 1420 830 1.2 2.0 2.1 35 2020 1430 120 4.5 0.1 16 1.9 29 1700 950 1.2 2.0 2.1 36 2310 1570 150 4.5 0.1 25 1.9 31 1990 1070 1.2 2.0 2.2 38 2660 1740 185 4.5 0.1 25 2.0 32 2380 1230 1.2 2.0 2.2 39 3070 1920 240 4.5 0.1 25 2.1 35 3010 1490 1.2 2.0 2.3 42 3750 2240 300 4.5 0.1 25 2.1 37 3620 1720 1.3 2.5 2.4 46 4590 2690 400 4.5 0.1 35 2.2 41 4490 2070 1.3 2.5 2.5 49 5550 3120 500 4.5 0.1 35 2.3 43 5460 2460 1.3 2.5 2.6 52 6590 3600 630 4.5 0.1 35 2.4 48 6790 2590 1.4 2.5 2.7 57 8060 4110 800 4.5 0.1 50 2.6 52 8420 3570 1.5 2.5 2.8 61 9800 4970 1000 4.5 0.1 50 2.7 55 10330 4180 1.6 2.5 3.0 65 10850 5710 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 25 727/1200 927/1538 3.6/2.3 171 0.47 2.6 0.6 150 210 480 680 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 187 0.51 2.6 0.6 141 207 460 660 679 1121 695 1131 50 387/641 494/822 6.8/4.4 204 0.57 2.6 0.7 138 195 440 640 511 834 527 844 70 268/443 343/568 9.8/6.3 232 0.63 2.6 0.7 132 188 420 600 364 583 386 597 95 193/320 248/410 13.3/8.5 258 0.71 2.6 0.8 126 182 400 580 272 427 300 446 120 153/253 196/325 17.2/11.0 281 0.74 2.6 0.8 119 179 380 570 225 345 257 367 150 124/206 159/265 21.2/13.5 301 0.79 4.3 0.9 113 176 360 560 193 287 229 313 185 99.1/164 128/211 26.6/17.0 329 0.87 4.3 0.9 110 170 350 540 165 237 206 267 240 75.4/125 98/161 34.9/22.3 363 0.96 4.3 1.0 107 166 340 530 140 191 185 226 300 60.1/100 80/130 43.8/28.0 398 1.03 4.3 1.1 104 160 330 510 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 439 1.17 5.8 1.2 97 157 310 500 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 483 1.28 5.8 1.3 94 154 300 490 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 534 1.42 5.8 1.4 91 151 290 480 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 590 1.61 8.2 1.4 91 147 290 470 92 101 147 153 1000 17.6/29.1 30/46 143.0/94.0 640 1.75 8.2 1.5 88 144 280 460 88 95 144 148 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 41:

39 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Single Core 12/20KV Um24KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 25 5.5 0.1 16 1.8 24 720 560 1.2 1.6 1.8 29 1200 980 35 5.5 0.1 16 1.8 25 840 620 1.2 1.6 1.9 30 1350 1070 50 5.5 0.1 16 1.8 26 990 690 1.2 2.0 2.0 33 1550 1250 70 5.5 0.1 16 1.8 28 1230 800 1.2 2.0 2.1 35 1840 1420 95 5.5 0.1 16 1.9 30 1530 940 1.2 2.0 2.1 37 2160 1570 120 5.5 0.1 16 2.0 31 1810 1050 1.2 2.0 2.2 38 2470 1730 150 5.5 0.1 25 2.0 33 2110 1190 1.2 2.0 2.2 40 2810 1890 185 5.5 0.1 25 2.1 35 2510 1360 1.2 2.0 2.3 42 3240 2090 240 5.5 0.1 25 2.1 38 3130 1610 1.3 2.5 2.4 45 4150 2580 300 5.5 0.1 25 2.2 40 3760 1860 1.3 2.5 2.5 48 4800 2890 400 5.5 0.1 35 2.3 43 4650 2220 1.4 2.5 2.6 52 5780 3350 500 5.5 0.1 35 2.4 46 5530 2545 1.5 2.5 2.7 55 6850 3850 630 5.5 0.1 35 2.5 50 6700 3100 1.5 2.5 2.9 60 8380 4400 800 5.5 0.1 50 2.6 55 8580 3690 1.6 2.5 3.0 64 10130 5270 1000 5.5 0.1 50 2.7 59 10620 4445 1.7 2.5 3.1 68 12180 6000 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 25 727/1200 927/1538 3.6/2.3 142 0.62 2.6 0.6 162 214 490 680 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 162 0.65 2.6 0.7 150 207 470 660 679 1121 695 1131 50 387/641 494/822 6.8/4.4 177 0.71 2.6 0.8 141 201 450 640 511 834 527 844 70 268/443 343/568 9.8/6.3 200 0.80 2.6 0.8 135 195 430 620 364 583 386 597 95 193/320 248/410 13.3/8.5 222 0.89 2.6 0.9 129 188 410 600 272 427 300 446 120 153/253 196/325 17.2/11.0 241 0.96 2.6 0.9 122 182 390 580 225 345 257 367 150 124/206 159/265 21.2/13.5 257 1.03 4.3 1.0 116 176 370 560 193 287 229 313 185 99.1/164 128/211 26.6/17.0 280 1.12 4.3 1.0 116 173 370 550 165 237 206 267 240 75.4/125 98/161 34.9/22.3 307 1.23 4.3 1.1 110 170 350 540 140 191 185 226 300 60.1/100 80/130 43.8/28.0 336 1.34 4.3 1.2 107 166 340 530 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 370 1.48 5.8 1.3 100 160 320 510 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 406 1.62 5.8 1.4 97 154 310 490 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 449 1.80 5.8 1.5 94 151 300 480 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 490 1.85 8.2 1.6 91 151 290 480 92 101 147 153 1000 17.6/29.1 30/46 143.0/94.0 540 2.03 8.2 1.7 87 148 280 470 88 95 144 148 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 42:

Caledonian Medium V oltage Cables Single Core 18/30KV Um36KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 50 8.0 0.1 16 2.0 31 1250 960 1.2 2.0 2.2 38 1910 1640 70 8.0 0.1 16 2.0 34 1510 1090 1.2 2.0 2.3 41 2240 1820 95 8.0 0.1 16 2.1 35 1830 1240 1.2 2.0 2.3 42 2570 1980 120 8.0 0.1 16 2.1 37 2110 1360 1.3 2.5 2.4 45 3060 2310 150 8.0 0.1 25 2.2 38 2420 1510 1.3 2.5 2.5 47 3430 2510 185 8.0 0.1 25 2.2 40 2830 1680 1.3 2.5 2.5 50 3890 2720 240 8.0 0.1 25 2.3 43 3500 1980 1.4 2.5 2.6 52 4630 3120 300 8.0 0.1 25 2.4 45 4150 2250 1.4 2.5 2.7 54 5330 3430 400 8.0 0.1 35 2.5 49 5070 2640 1.5 2.5 2.8 58 6360 3930 500 8.0 0.1 35 2.6 52 5945 2965 1.6 2.5 2.9 61 7670 4490 630 8.0 0.1 35 2.7 56 7445 3555 1.7 2.5 3.0 65 8870 5020 800 8.0 0.1 50 2.8 61 9060 4180 1.9 2.5 3.2 69 10790 5980 1000 8.0 0.1 50 2.9 65 11140 4980 2.0 2.5 3.3 73 12860 6730 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat spaced Trefoil Flat spaced Trefoil Flat spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/ m 50 387/641 494/822 6.8/4.4 138 0.83 2.6 1.0 151 214 480 680 511 834 527 844 70 268/443 343/568 9.8/6.3 154 0.92 2.6 1.0 144 201 460 640 364 583 386 597 95 193/320 248/410 13.3/8.5 169 1.01 2.6 1.1 138 195 440 620 272 427 300 446 120 153/253 196/325 17.2/11.0 183 1.10 2.6 1.1 132 188 420 600 225 345 257 367 150 124/206 159/265 21.2/13.5 194 1.16 4.3 1.2 126 182 400 580 193 287 229 313 185 99.1/164 128/211 26.6/17.0 210 1.26 4.3 1.2 122 182 390 580 165 237 206 267 240 75.4/125 98/161 34.9/22.3 229 1.37 4.3 1.3 119 176 380 560 140 191 185 226 300 60.1/100 80/130 43.8/28.0 249 1.49 4.3 1.4 113 173 360 550 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 273 1.64 5.8 1.5 107 163 340 520 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 298 1.79 5.8 1.6 104 163 330 520 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 327 1.96 5.8 1.7 100 160 320 510 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 350 1.98 8.2 1.8 97 154 310 490 92 101 147 153 1000 17.6/29.1 30/46 143.0/94.0 380 2.15 8.2 1.9 94 149 300 490 88 95 144 148 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 43:

41 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Single Core 21/35KV Um42KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 50 9.3 0.1 16 2.0 35.7 1526 1239 1.2 2.0 2.3 43.5 2331 2116 70 9.3 0.1 16 2.1 37.6 1809 1393 1.2 2.5 2.4 46.6 2680 2325 95 9.3 0.1 16 2.2 39.4 2123 1555 1.2 2.5 2.5 48.4 2981 2482 120 9.3 0.1 16 2.2 40.8 2405 1688 1.4 2.5 2.5 49.8 3487 2867 150 9.3 0.1 25 2.2 42.3 2733 1838 1.4 2.5 2.6 51.5 3870 3055 185 9.3 0.1 25 2.3 44.7 3216 2082 1.4 2.5 2.6 53.5 4420 3370 240 9.3 0.1 25 2.4 46.9 3766 2333 1.4 2.5 2.7 55.8 4981 3676 300 9.3 0.1 25 2.4 49.3 4408 2605 1.4 2.5 2.8 58.5 5661 3971 400 9.3 0.1 35 2.5 52.3 5473 3057 1.6 2.5 2.9 61.7 6865 4550 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/ m 50 387/641 494/822 6.8/4.4 130 0.89 2.6 1.1 156 220 495 700 511 834 527 844 70 268/443 343/568 9.8/6.3 144 0.98 2.6 1.1 150 204 475 650 364 583 386 597 95 193/320 248/410 13.3/8.5 159 1.06 2.6 1.2 142 198 455 630 272 427 300 446 120 153/253 196/325 17.2/11.0 171 1.18 2.6 1.2 137 191 435 610 225 345 257 367 150 124/206 159/265 21.2/13.5 180 1.26 4.3 1.3 131 185 415 590 193 287 229 313 185 99.1/164 128/211 26.6/17.0 193 1.34 4.3 1.3 125 185 400 590 165 237 206 267 240 75.4/125 98/161 34.9/22.3 210 1.45 4.3 1.4 123 179 390 570 140 191 185 226 300 60.1/100 80/130 43.8/28.0 228 1.57 4.3 1.5 116 176 370 560 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 249 1.74 5.8 1.6 110 166 350 530 113 141 164 184 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 44:

Caledonian Medium V oltage Cables Single Core 26/35KV Um42KV Dimensional Data Nom. Cross- Section Area Unarmoured Cables Aluminium Wire Armoured Cables Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 50 10.5 0.1 16 2.1 38.3 1689 1402 1.2 2.5 2.5 46.8 2580 2395 70 10.5 0.1 16 2.2 40.2 1980 1564 1.2 2.5 2.5 48.8 2937 2611 95 10.5 0.1 16 2.2 41.8 2283 1714 1.2 2.5 2.6 50.9 3206 2737 120 10.5 0.1 16 2.3 43.4 2588 1871 1.4 2.5 2.6 51.5 3753 3177 150 10.5 0.1 25 2.3 44.9 2923 2028 1.4 2.5 2.7 53.8 4143 3371 185 10.5 0.1 25 2.4 47.3 3415 2281 1.4 2.5 2.7 55.6 4694 3693 240 10.5 0.1 25 2.5 49.5 3975 2542 1.4 2.5 2.8 57.6 5258 4005 300 10.5 0.1 25 2.5 51.9 4625 2822 1.4 2.5 2.9 60.8 5940 4301 400 10.5 0.1 35 2.6 54.9 5704 3288 1.6 2.5 3.0 63.6 7155 4894 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/ m 50 387/641 494/822 6.8/4.4 126 0.95 2.6 1.2 161 227 510 720 511 834 527 844 70 268/443 343/568 9.8/6.3 138 1.04 2.6 1.2 154 207 490 660 364 583 386 597 95 193/320 248/410 13.3/8.5 151 1.13 2.6 1.3 147 202 470 640 272 427 300 446 120 153/253 196/325 17.2/11.0 161 1.24 2.6 1.3 142 194 450 620 225 345 257 367 150 124/206 159/265 21.2/13.5 169 1.36 4.3 1.4 136 188 430 600 193 287 229 313 185 99.1/164 128/211 26.6/17.0 176 1.40 4.3 1.4 128 188 410 600 165 237 206 267 240 75.4/125 98/161 34.9/22.3 192 1.51 4.3 1.5 128 183 400 580 140 191 185 226 300 60.1/100 80/130 43.8/28.0 209 1.64 4.3 1.6 119 180 380 570 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 227 1.80 5.8 1.7 114 170 360 540 113 141 164 184 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 45:

43 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Current Rating for Single Core 1.8/3KVUm3.6KV to 26/35KVUm42KV XLPE Insulation Nom. Cross- Section Area Buried direct in Ground Laid in Single Way Duct Laid in Air Trefoil Flat spaced Trefoil Flat Touching Trefoil Flat Touching Flat spaced CU AL CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A A 10 84 59 87 62 78 55 98 56 103 75 106 77 122 88 16 109 84 113 88 103 80 104 81 125 97 128 99 150 116 25 140 108 144 112 132 102 133 103 163 127 167 130 196 153 35 166 129 172 134 157 122 159 123 198 154 203 157 238 185 50 196 152 203 157 186 144 188 146 238 184 243 189 286 222 70 239 186 246 192 227 176 229 178 296 230 303 236 356 278 95 285 221 293 229 271 210 274 213 361 280 369 287 434 338 120 323 252 332 260 308 240 311 242 417 324 426 332 500 391 150 361 281 366 288 343 267 347 271 473 368 481 376 559 440 185 406 317 410 324 387 303 391 307 543 424 550 432 637 504 240 469 367 470 373 447 351 453 356 641 502 647 511 745 593 300 526 414 524 419 504 397 510 402 735 577 739 586 846 677 400 590 470 572 466 564 451 571 457 845 673 837 676 938 769 500 650 530 672 546 604 504 661 537 935 773 938 776 1118 919 630 700 600 882 646 654 554 771 617 1045 883 1048 886 1318 1089 800 750 660 1002 756 694 594 871 717 1145 983 1148 986 1528 1279 1000 800 720 1112 856 724 644 971 807 1235 1083 1238 1086 1738 1469 Current Rating for Single Core 1.8/3KVUm3.6KV to 26/35KVUm42KV EPR Insulation Nom. Cross- Section Area Buried direct in Ground Laid in Single Way Duct Laid in Air Trefoil Flat spaced Trefoil Flat Touching Trefoil Flat Touching Flat spaced CU AL CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A A 10 81 57 83 58 74 52 94 53 94 68 97 70 110 79 16 106 82 109 84 99 77 100 78 116 90 119 92 138 107 25 136 105 140 109 128 99 129 100 153 119 156 121 181 141 35 162 126 167 130 153 118 154 120 186 144 190 147 221 171 50 192 149 198 153 181 140 183 142 224 174 229 178 266 207 70 234 182 242 188 222 172 224 174 280 218 287 223 334 259 95 280 217 289 224 266 206 269 208 343 266 352 273 409 317 120 319 247 329 256 303 235 306 238 398 309 407 317 474 368 150 357 277 369 287 341 264 344 267 454 352 465 361 540 419 185 403 314 417 325 386 300 390 303 522 406 534 417 621 484 240 467 364 484 377 449 350 454 354 619 483 634 495 736 575 300 526 411 545 426 509 397 515 401 712 556 728 570 843 659 400 597 471 618 487 580 456 588 462 825 651 843 667 977 770 500 657 531 718 567 620 509 678 542 915 751 849 767 1157 920 630 707 601 928 667 670 559 788 622 1025 862 1054 876 1357 1090 800 757 661 1048 777 710 599 888 722 1125 961 1154 977 1567 1280 1000 807 721 1158 877 740 649 988 812 1215 1061 1244 1077 1777 1470 ▓ Current Rating Conditions: Ground Temperature: 20°C Ambient Temperature air: 30°C Depth of Soil: 0.8m Thermal Resistance of Soil: 1.5K•m/W

slide 46:

Caledonian Medium V oltage Cables Three Core Cables to IEC 60502 ▓ APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations indoors and in cable ducts outdoors underground and in water as well as for installation on cable trays for industries switchboards and power stations. ▓ STANDARD: IEC 60502 Part 11.8/3KV IEC 60502 Part 23.6/6KV to 18/30KV ▓ CONSTRUCTION: Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. Conductor Screen: The conductor screen consists of an extruded layer of non metallic semi-conducting compound applied on top of a semi-conducting tape. The conductor screen is applied under triple extrusion process over the conductor along with the insulation and the insulation screen. The extruded semi-conducting compound is frmly bonded to the insulation to exclude all air voids and can be easily hand stripped on site. The conductor screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3.6KV and 3.6/6KV cables. Insulation: Insulation is of polyvinyl chloride PVC intended for 1.8/3.6KV and 3.6/6KV cables cross-linked polyethylene compound XLPE or ethylene propylene rubber EPR/ HEPR. Table 1. Insulation Thickness of XLPE or EPR/HEPR Insulation Nom. Cross Section Area Insulation Thickness at Nom. Voltage 1.8/3KV Um3.6KV 3.6/6KV Um7.2KV 6/10KV Um12KV 8.7/15KV Um17KV 12/20KV Um24KV 18/30KV Um36KV 21/35KV Um42KV 26/35KV Um42KV mm² mm mm mm mm mm mm mm mm XLPE/EPR XLPE EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR Unscreened Screened 10 2.0 2.5 3.0 2.5 - - - - - - 16 2.0 2.5 3.0 2.5 3.4 - - - - - 25 2.0 2.5 3.0 2.5 3.4 4.5 - - - - 35 2.0 2.5 3.0 2.5 3.4 4.5 5.5 - - - 50 – 185 2.0 2.5 3.0 2.5 3.4 4.5 5.5 8.0 9.3 10.5 240 2.0 2.6 3.0 2.6 3.4 4.5 5.5 8.0 9.3 10.5 300 2.0 2.8 3.0 2.8 3.4 4.5 5.5 8.0 9.3 10.5 400 2.0 3.0 3.0 3.0 3.4 4.5 5.5 8.0 9.3 10.5 500 - 1600 2.2-2.8 3.2 3.2 3.2 3.4 4.5 5.5 8.0 9.3 10.5 Binder PVC/PE/LSZH Over Sheath Armour optional XLPE/EPR/HEPR Insulation Conductor Conductor Screen Insulation Screen Metallic Screen PVC/PE/LSZH Separation Sheath optional

slide 47:

45 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Insulaton Screen: The insulation screen consists of an extruded layer of non metallic semi-conducting compound extruded over the insulation of each core. The extruded semi- conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option a semi-conducting tape may be applied over the individual cores or core assembly as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly ftted to the insulation to exclude all air voids and can be easily hand stripped on site. The insulation screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3.6KV and 3.6/6KV cables. The screen may be covered by semi-conductive water blocking swellable tape to ensure longitudinal watertightness. Inner Covering Fillers: For cables with a collective metallic layer or cables with a metallic layer over each individual cores with additional collective metallic layers semi-conducting inner covering and fllers shall be applied over the laid up cores. The inner covering and fllers are made of non hygroscopic material like polypropylene except if the cable is to be made longitudinally watertight. The inner covering is extruded in general but may be lapped if the interstices between the cores are flled. The approximate thickness of extruded inner coverings is given in Table 2: Table 2. Approximate Thickness of Extruded Inner Coverings Ficititous Diameter over Laid Up Cores Approx. Thickress of Extruded Inner Covering mm mm - 25 1.0 25 35 1.2 35 45 1.4 45 60 1.6 60 80 1.8 80 - 2.0 The approximate thickness of lapped inner coverings shall be 0.4mm for fctitious diameters over the laid up cores up to and including 40mm and 0.6mm for larger diameter. Metallic Layer: The metallic layer may be applied over the individual cores or the core assembly collectively. The following types of metallic layers are provided: 1 Metallic Screen 2 Concentric Conductor 3 Metallic Sheath 4 Metallic Armour The metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The concentric conductor is applied directly over the inner covering. The metallic sheath consists of lead or lead alloy applied as a tightly ftting seamless tube. The metallic armour consists of either fat wire armour round wire armour and double tape armour.

slide 48:

Caledonian Medium V oltage Cables Table 3. Minimum Total Cross Section of Metallic Screen Nom. Cross-Section Area of Cable Min. Cross-Section of Metallic Screen DC Resistance of the Copper Wire Screen mm² mm² mm up to 120 16 1.06 150-300 25 0.72 400-630 35 0.51 800-1000 50 0.35 Separation Sheath for armoured cable: The separation sheath comprises a layer of extruded PVC PE or LSZH applied over the laid up cores under the armour. PVC is normally of grade ST2 and PE of grade ST7. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fctitious diameter under the sheath in mm. For cables without a lead sheath the nominal separation sheath thickness shall not be less than 1.2mm. For cables where the separation sheath is applied over the lead sheath the nominal separation sheath thickness shall not be less than 1.0mm. Tabel 4. Separation Thickness Cores Diameter Approx. Thickress of Inner Sheath mm mm 35 45 1.4 45 60 1.6 60 80 1.8 80 - 2.0 Lapped Bedding for armoured lead sheathed cable: The lapped bedding applied to the lead sheath consists of either impregnated/synthetic compounded paper tapes or a combination of two layers of these paper tapes followed by a few layers of compounded fabulous materials. The thickness is around 1.5mm. Armour for armoured cable: The armour is applied over the inner covering helically. It consists of either fat galvanized steel wire armour strip round galvanized steel wire armour and double steel tape armour. Table 5. Round Armour Wire Diameter Fictitious Diameter under the Armour Armour Wire Diameter mm mm - 10 1.25 10 15 1.25 15 25 1.6 25 35 2.0 35 60 2.5 60 - 3.15

slide 49:

47 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Table 6. Armour Tape Thickness Fictitious Diameter under the Armour Galvanized Steel / Steel Aluminum / Aluminium Alloy mm mm mm - 30 0.2 0.5 30 70 0.5 0.5 70 - 0.8 0.8 For fat wire armour and fctitious diameter under the armour greater than 15mm the nominal thickness of the fat steel wire diameter shall be 0.8mm.Cables with fctitious diameter under the armour up to and including 15mm fat wire armour will not be used. The tape armour is applied helically in two layers so that the outer tape is approximately central over the gap of the inner tape. If tape armour is used the inner covering shall be reinforced by taped bedding. Over Sheath: Overall sheath comprises a layer of extruded either thermoplastic compound PVC ST3 type or PE ST7 type or LSZH or elastomeric compound polychlorprene CSP or chlorosulfonated PE. The nominal over sheath thickness is calculated by 0.035D+1 where D is the fctitiuous diameter immediately under the over sheath in mm. For unarmoured cables and cables with the over sheath not applied over the armour metallic screen or concentric conductor the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour metallic screen or concentric conductor the nominal over sheath thickness shall not be less than 1.8mm. ▓ PHYSICAL PROPERTIES: Operating Temperature: up to 70°C PVC insulation up to 90°C XLPE or EPR insulation Temperature Range: -5°C PVC or LSZH sheath -20°C PE sheath Short Circuit Temperature 5 seconds maximum duration : 140-160 °C PVC insulation 250°C XLPE or EPR insulation Bending Radius: 15 x OD Table 7. Nominal /Operating /Testing Voltages Rated Voltage Uo/U Operating Voltage Um Testing Voltage rms 1.8/3KV 3.6KV 6.5KV 3.6/6KV 7.2KV 12.5KV 6/10KV 12KV 21KV 8.7/15KV 17.5KV 30.5KV 12/20KV 24KV 42KV 18/30KV 36KV 63KV 21/35KV 42KV 73.553KV 26/35KV 42KV 9165KV 21/35KV and 26/35KV power frequency voltage test can be made under the following conditions: 2.5Uo x 30mins or 3.0Uo x 15mins. Numbers in brackets refer to the test values for 3.0Uo x 1.5mins.

slide 50:

Caledonian Medium V oltage Cables Three Core 1.8/3KV Um3.6KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 10 2.0 0.1 16 1.8 23 650 460 1.2 1.6 1.8 28 1480 1290 16 2.0 0.1 16 1.8 24 840 540 1.2 1.6 1.9 29 1720 1410 25 2.0 0.1 16 1.8 26 1160 680 1.2 1.6 1.9 32 2130 1650 35 2.0 0.1 16 1.8 29 1490 820 1.2 2.0 2.1 36 2810 2140 50 2.0 0.1 16 1.9 32 1900 1000 1.2 2.0 2.2 39 3340 2450 70 2.0 0.1 16 2.0 36 2580 1290 1.2 2.0 2.3 42 4200 2910 95 2.0 0.1 16 2.2 40 3440 1640 1.3 2.5 2.4 47 5620 3820 120 2.0 0.1 16 2.3 43 4220 1950 1.3 2.5 2.5 51 6580 4310 150 2.0 0.1 25 2.4 46 5090 2290 1.4 2.5 2.7 54 7680 4870 185 2.0 0.1 25 2.5 50 6240 2730 1.5 2.5 2.8 58 9060 5560 240 2.0 0.1 25 2.7 56 8030 3430 1.6 2.5 3.0 64 11200 6600 300 2.0 0.1 25 2.8 60 9890 4100 1.6 2.5 3.1 69 13590 7500 400 2.0 0.1 35 3.1 68 12530 5150 1.8 3.15 3.4 78 17260 9880 500 2.2 0.1 35 3.3 75.7 16680 7510 1.8 3.15 3.5 84.3 21780 13025 630 2.4 0.1 35 3.5 84.9 21770 10040 1.8 3.15 3.8 94.6 27400 16050 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Steel Flat Wire Armoured Cables Double Steel T ape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom.Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness No of Steel T apes x Nom Tape Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 10 1.2 0.8 1.8 24.5 1245 1065 1.2 2 x 0.2 1.8 23.6 925 750 16 1.2 0.8 1.8 27.1 1565 1280 1.2 2 x 0.2 1.8 26.2 1205 925 25 1.2 0.8 1.8 29.7 1975 1525 1.2 2 x 0.2 1.9 29.0 1590 1145 35 1.2 0.8 1.9 32.5 2420 1805 1.2 2 x 0.2 1.9 31.6 1985 1370 50 1.2 0.8 2.0 35 2860 2080 1.2 2 x 0.2 2.0 34.1 2400 1605 70 1.2 0.8 2.1 38.7 3685 2525 1.2 2 x 0.5 2.2 39.5 3570 2410 95 1.3 0.8 2.2 42.9 4695 3080 1.3 2 x 0.5 2.3 43.7 4570 2950 120 1.3 0.8 2.3 46.4 5650 3585 1.3 2 x 0.5 2.4 46.1 5510 3440 150 1.4 0.8 2.4 49.6 6630 4085 1.4 2 x 0.5 2.6 50.6 6500 3955 185 1.5 0.8 2.6 54.1 7990 4820 1.5 2 x 0.5 2.7 54.9 7825 4650 240 1.6 0.8 2.7 59.2 10060 5790 1.6 2 x 0.5 2.8 60.0 9825 5600 300 1.6 0.8 2.9 64.6 12230 6865 1.6 2 x0.5 3.0 65.4 12030 6660 400 1.8 0.8 3.1 71.0 15200 8280 1.8 2 x 0.5 3.2 71.8 14970 8055 500 1.8 0.8 3.3 79.5 19090 10255 1.8 2 x 0.8 3.5 80.5 18880 10035 630 1.8 0.8 3.6 89.8 24400 12920 1.8 2 x 0.8 3.8 92.3 25070 13620

slide 51:

49 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 10 1830/3080 2330/3920 1.4/0.9 160 0.25 2.6 0.4 101 390 16 1150/1910 1460/2420 2.2/1.4 180 0.27 2.6 0.4 98 370 25 727/1200 929/1538 3.6/2.3 220 0.29 2.6 0.4 95 350 35 524/868 668/1113 5.0/3.2 250 0.31 2.6 0.5 92 330 50 387/641 494/822 6.8/4.4 270 0.33 2.6 0.5 88 310 70 268/443 343/568 9.8/6.3 310 0.35 2.6 0.6 84 290 95 193/320 248/410 13.3/8.5 350 0.38 2.6 0.6 81 270 120 153/253 196/325 17.2/11.0 380 0.46 2.6 0.7 79 250 150 124/206 159/265 21.2/13.5 420 0.50 2.6 0.7 77 260 185 99.1/164 128/211 26.6/17.0 460 0.56 2.6 0.8 76 250 240 75.4/125 98/161 34.9/22.3 510 0.61 4.3 0.9 74 240 300 60.1/100 80/130 43.8/28.0 570 0.68 4.3 1.0 73 250 400 47.0/77.8 64/102 57.3/36.6 590 0.70 5.8 1.1 71 240 500 36.6/60.5 57/81 72.3/46.2 610 0.72 5.8 1.2 69 230 630 28.3/46.9 42/64 91.2/58.3 630 0.74 5.8 1.3 67 220 Three Core 3.8/6.6KV Um7.2KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx.Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 10 2.5 0.1 16 2.0 30 980 790 1.2 2.0 2.1 36 2310 2120 16 2.5 0.1 16 2.0 31 1190 890 1.2 2.0 2.2 38 2600 2290 25 2.5 0.1 16 2.1 34 1560 1080 1.2 2.0 2.3 41 3080 2600 35 2.5 0.1 16 2.2 37 1930 1270 1.3 2.5 2.4 45 3950 3280 50 2.5 0.1 16 2.3 40 2370 1480 1.3 2.5 2.5 47 4530 3630 70 2.5 0.1 16 2.4 43 3110 1820 1.4 2.5 2.6 51 5510 4210 95 2.5 0.1 16 2.5 47 4000 2200 1.5 2.5 2.8 55 6660 4860 120 2.5 0.1 16 2.6 50 4820 2550 1.5 2.5 2.9 59 7630 5360 150 2.5 0.1 25 2.8 54 5770 2970 1.6 2.5 3.0 62 8800 6000 185 2.5 0.1 25 2.9 58 6960 3460 1.6 2.5 3.1 66 10180 6670 240 2.6 0.1 25 3.1 65 8940 4340 1.8 3.15 3.4 75 13480 8870 300 2.8 0.1 25 3.3 70 10980 5190 1.9 3.15 3.6 81 15920 10130 400 3.0 0.1 35 3.5 79 13820 6440 2.0 3.5 3.9 90 19980 12590 500 3.2 0.1 35 3.7 87 19100 10755 2.1 3.5 4.1 98 24160 14820 630 3.2 0.1 35 4.0 95 30470 13150 2.2 3.5 4.4 107 29650 17710 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard.

slide 52:

Caledonian Medium V oltage Cables Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness No of Steel tapes x nom tape thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 10 1.2 0.8 1.8 26.9 1415 1235 1.2 2X0.2 1.8 26 1060 885 16 1.2 0.8 1.8 29.2 1725 1445 1.2 2X0.2 1.8 28.3 1340 1055 25 1.2 0.8 1.9 32.2 2165 1735 1.2 2X0.2 1.9 31.3 1735 1305 35 1.3 0.8 2.0 35.0 2645 2025 1.3 2X0.2 2.0 34.1 2170 1555 50 1.3 0.8 2.1 37.4 3075 2295 1.3 2X0.5 2.1 38.0 2950 2170 70 1.4 0.8 2.2 41.0 3915 2755 1.4 2X0.5 2.3 41.8 3795 2635 95 1.5 0.8 2.3 45.3 4840 3335 1.5 2X0.5 2.4 46.1 4810 3200 120 1.5 0.8 2.4 48.7 5915 3855 1.5 2X0.5 2.5 49.5 5770 3705 150 1.6 0.8 2.5 52.1 6930 4395 1.6 2X0.5 2.6 52.9 6775 4235 185 1.6 0.8 2.6 56.2 8265 5100 1.6 2X0.5 2.8 57.2 8120 4950 240 1.8 0.8 2.8 62.2 10440 6220 1.8 2X0.5 2.9 63.0 10250 6025 300 1.9 0.8 3.0 68.2 12780 7420 1.9 2X0.5 3.1 69.0 12570 7200 400 2.0 0.8 3.3 75.9 15970 9110 2.0 2X0.5 3.4 76.7 15740 8870 500 2.1 0.8 3.5 84.2 19940 11130 2.1 2X0.8 3.6 86.5 20550 11750 630 2.2 0.8 3.7 93.5 25120 13670 2.2 2X0.8 3.9 96.0 25830 14400 Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 10 1830/3080 2330/3920 1.4/0.9 212 0.27 2.6 0.4 132 410 16 1150/1910 1470/2420 2.2/1.4 242 0.30 2.6 0.4 124 390 25 727/1200 927/1538 3.6/2.3 272 0.33 2.6 0.4 116 370 35 524/868 668/1113 5.0/3.2 301 0.36 2.6 0.5 108 350 50 387/641 494/822 6.8/4.4 332 0.40 2.6 0.5 102 330 70 268/443 343/568 9.8/6.3 383 0.46 2.6 0.6 97 310 95 193/320 248/410 13.3/8.5 432 0.52 2.6 0.6 92 290 120 153/253 196/325 17.2/11.0 474 0.57 2.6 0.7 89 280 150 124/206 159/265 21.2/13.5 511 0.61 4.3 0.7 87 280 185 99.1/164 128/211 26.6/17.0 562 0.67 4.3 0.8 86 270 240 75.4/125 98/161 34.9/22.3 602 0.72 4.3 0.9 83 260 300 60.1/100 80/130 43.8/28.0 622 0.75 4.3 1.0 82 260 400 47.0/77.8 64/102 57.3/36.6 648 0.78 5.8 1.1 80 250 500 36.6/60.5 51/81 72.3/46.2 668 0.82 5.8 1.2 78 250 630 28.3/46.9 42/64 91.2/58.3 758 0.92 5.8 1.3 76 240

slide 53:

51 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Three Core 6/10KV Um12KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 16 3.4 0.1 16 2.2 36 1410 1110 1.2 2.0 2.4 42 3000 2700 25 3.4 0.1 16 2.3 39 1800 1320 1.3 2.5 2.5 46 3900 3430 35 3.4 0.1 16 2.3 41 2170 1500 1.3 2.5 2.6 49 4430 3770 50 3.4 0.1 16 2.4 44 2630 1730 1.4 2.5 2.7 52 5080 4190 70 3.4 0.1 16 2.6 48 3400 2110 1.5 2.5 2.8 56 6050 4750 95 3.4 0.1 16 2.7 52 4310 2510 1.5 2.5 2.9 60 7180 5380 120 3.4 0.1 16 2.8 55 5150 2890 1.6 2.5 3.0 63 8230 5960 150 3.4 0.1 25 2.9 58 6100 3300 1.7 2.5 3.1 67 9380 6580 185 3.4 0.1 25 3.0 62 7310 3810 1.7 3.15 3.3 72 11610 8110 240 3.4 0.1 25 3.2 69 9290 4680 1.8 3.15 3.5 79 14110 9510 300 3.4 0.1 25 3.3 73 11240 5450 1.9 3.15 3.7 84 16420 10630 400 3.4 0.1 35 3.6 81 14040 6660 2.0 3.5 3.9 92 20620 12880 500 3.4 0.1 35 3.7 88 17830 8450 2.1 3.5 4.0 99. 25090 16530 630 3.4 0.1 35 3.9 96 20030 10895 2.2 3.5 4.1 109 30880 19670 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness No of Steel tapes x nom tape thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 16 1.2 0.8 2.2 39.7 2795 2515 1.2 2x0.5 2.3 40.5 2680 2395 25 1.3 0.8 2.2 42.7 3305 2885 1.3 2x0.5 2.4 43.7 3195 2775 35 1.3 0.8 2.3 45.2 3835 3215 1.3 2x0.5 2.5 46.2 3720 3100 50 1.4 0.8 2.4 47.8 4325 3570 1.4 2x0.5 2.6 48.8 4200 3445 70 1.5 0.8 2.5 51.8 5320 4185 1.5 2x0.5 2.7 52.8 5185 4050 95 1.5 0.8 2.7 56.1 6450 4875 1.5 2x0.5 2.8 56.9 6280 4700 120 1.6 0.8 2.8 59.7 7545 5510 1.6 2x0.5 2.9 60.5 7360 5325 150 1.7 0.8 2.9 63.1 8610 6150 1.7 2x0.5 3.0 63.9 8420 5950 185 1.7 0.8 3.0 67.4 10120 6995 1.7 2x0.5 3.1 68.2 9910 6780 240 1.8 0.8 3.2 73.0 12430 8205 1.8 2x0.5 3.3 73.8 12200 7970 300 1.9 0.8 3.3 78.3 14775 9455 1.9 2x0.5 3.4 79.1 14530 9200 400 2.0 0.8 3.5 85.2 17950 11190 2.0 2x0.8 3.7 87.7 18600 11850 500 2.1 0.8 3.7 92.8 21970 13270 2.1 2x0.8 3.9 95.3 22680 13990 630 2.2 0.8 4.0 102.7 27480 16160 2.2 2x0.8 4.1 105.0 28200 16910

slide 54:

Caledonian Medium V oltage Cables Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Wire Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 16 1150/1910 1470/2420 2.2/1.4 186 0.40 2.6 0.5 131 410 25 727/1200 927/1538 3.6/2.3 216 0.43 2.6 0.5 123 390 35 524/868 668/1113 5.0/3.2 237 0.47 2.6 0.6 115 370 50 387/641 494/822 6.8/4.4 266 0.52 2.6 0.6 109 350 70 268/443 343/568 9.8/6.3 298 0.60 2.6 0.7 103 330 95 193/320 248/410 13.3/8.5 334 0.67 2.6 0.7 99 320 120 153/253 196/325 17.2/11.0 365 0.73 2.6 0.8 96 310 150 124/206 159/265 21.2/13.5 392 0.78 4.3 0.8 93 300 185 99.1/164 128/211 26.6/17.0 430 0.86 4.3 0.9 90 290 240 75.4/125 98/161 34.9/22.3 476 0.95 4.3 0.9 87 280 300 60.1/100 80/130 43.8/28.0 524 1.05 4.3 1.0 85 270 400 47.0/77.8 64/102 57.3/36.6 580 1.16 5.8 1.1 81 260 500 36.6/60.5 51/81 72.3/46.2 630 1.26 5.8 1.2 78 250 630 28.3/46.9 42/64 91.2/58.3 690 1.36 5.8 1.3 76 240

slide 55:

53 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Three Core 8.7/15KV Um17.5KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 25 4.5 0.1 16 2.4 44 2100 1620 1.4 2.5 2.7 52 4560 4080 35 4.5 0.1 16 2.5 46 2510 1840 1.4 2.5 2.7 54 5080 4410 50 4.5 0.1 16 2.6 49 2980 2080 1.5 2.5 2.9 57 5740 4840 70 4.5 0.1 16 2.7 53 3760 2470 1.6 2.5 3.0 62 6770 5480 95 4.5 0.1 16 2.8 57 4700 2900 1.6 2.5 3.1 65 7890 6100 120 4.5 0.1 16 3.0 60 5590 3320 1.7 2.5 3.2 69 8970 6700 150 4.5 0.1 25 3.1 64 6560 3760 1.8 3.15 3.4 74 11030 8220 185 4.5 0.1 25 3.2 67 7800 4300 1.8 3.15 3.5 78 12490 8980 240 4.5 0.1 25 3.4 74 9820 5220 1.9 3.15 3.7 84 15040 10440 300 4.5 0.1 25 3.5 79 11800 6010 2.0 3.5 3.8 90 17920 12130 400 4.5 0.1 35 3.7 86 14620 7240 2.1 3.5 4.1 98 21360 13970 500 4.5 0.1 35 3.8 93 18160 9355 2.2 3.5 4.3 106 26490 17830 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness No of Steel tapes x Nom Tape Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 25 1.4 0.8 2.4 48.0 3915 3495 1.4 2x0.5 2.5 48.8 3770 3345 35 1.4 0.8 2.5 50.8 4510 3890 1.4 2x0.5 2.6 51.6 4350 3735 50 1.5 0.8 2.6 53.3 5020 4270 1.5 2x0.5 2.7 54.1 4855 4105 70 1.6 0.8 2.7 57.0 5990 4870 1.6 2x0.5 2.8 57.8 5815 4690 95 1.6 0.8 2.8 61.2 7170 5600 1.6 2x0.5 3.0 62.2 7010 5435 120 1.7 0.8 2.9 65.1 8340 6320 1.7 2x0.5 3.1 66.1 8170 6145 150 1.8 0.8 3.0 68.3 9440 6955 1.8 2x0.5 3.2 69.3 9260 6770 185 1.8 0.8 3.2 72.8 10990 7880 1.8 2x0.5 3.3 73.6 10760 7650 240 1.9 0.8 3.3 78.3 13370 9155 1.9 2x0.5 3.4 79.1 13120 8900 300 2.0 0.8 3.5 83.7 15760 10460 2.0 2x0.8 3.6 86.0 16360 11070 400 2.1 0.8 3.7 90.5 19050 12260 2.1 2x0.8 3.9 93.0 19750 12960 500 2.2 0.8 3.9 98.2 23160 14430 2.2 2x0.8 4.1 100.7 23900 15190

slide 56:

Caledonian Medium V oltage Cables Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩm µΩ/m kA pF/m mA/m kA kA µΩm nH/m 25 727/1200 927/1538 3.6/2.3 176 0.48 2.6 0.6 132 410 35 524/868 668/1113 5.0/3.2 193 0.53 2.6 0.6 123 390 50 387/641 494/822 6.8/4.4 211 0.58 2.6 0.7 116 370 70 268/443 343/568 9.8/6.3 240 0.65 2.6 0.7 110 350 95 193/320 248/410 13.3/8.5 267 0.73 2.6 0.8 105 330 120 153/253 196/325 17.2/11.0 291 0.79 2.6 0.8 102 320 150 124/206 159/265 21.2/13.5 312 0.85 4.3 0.9 98 310 185 99.1/164 128/211 26.6/17.0 340 0.93 4.3 0.9 95 300 240 75.4/125 98/161 34.9/22.3 375 1.02 4.3 1.0 91 290 300 60.1/100 80/130 43.8/28.0 411 1.12 4.3 1.1 89 280 400 47.0/77.8 64/102 57.3/36.6 454 1.24 5.8 1.2 84 270 500 36.6/60.5 51/81 72.3/46.2 504 1.34 5.8 1.3 78 250 Three Core12/20KV Um24KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 35 5.5 0.1 16 2.7 51 2850 2180 1.5 2.5 2.9 60 5700 5010 50 5.5 0.1 16 2.8 54 3340 2450 1.6 2.5 3.0 62 6370 5480 70 5.5 0.1 16 2.9 58 4150 2850 1.6 2.5 3.1 66 7370 6070 95 5.5 0.1 16 3.0 62 5110 3310 1.7 3.15 3.3 72 9400 7600 120 5.5 0.1 16 3.1 65 5990 3730 1.8 3.15 3.4 75 10530 8270 150 5.5 0.1 25 3.2 68 6980 4180 1.8 3.15 3.5 80 11800 8940 185 5.5 0.1 25 3.3 72 8240 4740 1.9 3.15 3.7 83 13350 9850 240 5.5 0.1 25 3.6 79 10310 5700 2.0 3.5 3.8 90 16430 11820 300 5.5 0.1 25 3.7 84 12360 6570 2.1 3.5 4.0 95 18870 13080 400 5.5 0.1 35 3.9 91 15220 7830 2.2 4.0 4.3 103 23260 15930 500 5.5 0.1 35 4.1 97 19105 10325 2.3 4.2 4.5 110 27800 19170 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard.

slide 57:

55 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness No of Steel tapes x nom tape thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 35 1.5 0.8 2.7 55.7 5150 4530 1.5 2x0.5 2.8 56.5 4975 4355 50 1.6 0.8 2.8 58.2 5675 4935 1.6 2x0.5 2.9 59.0 5495 4750 70 1.6 0.8 2.9 61.9 6685 5570 1.6 2x0.5 3.0 62.7 6490 5375 95 1.7 0.8 3.0 66.4 7945 6390 1.7 2x0.5 3.1 67.2 7735 6180 120 1.8 0.8 3.1 70.0 9110 7103 1.8 2x0.5 3.2 70.8 8890 6880 150 1.8 0.8 3.2 73.2 10240 7770 1.8 2x0.5 3.3 74.0 10010 7535 185 1.9 0.8 3.3 77.7 11840 8750 1.9 2x0.5 3.4 78.5 11600 8500 240 2.0 0.8 3.5 83.2 14270 10070 2.0 2x0.8 3.6 85.5 14870 10680 300 2.1 0.8 3.6 88.6 16730 11440 2.1 2x0.8 3.8 91.1 17400 12130 400 2.2 0.8 3.9 95.6 20130 13350 2.2 2x0.8 4.0 97.9 20820 14050 500 2.3 0.8 4.1 103.3 24310 15600 2.3 2x0.8 4.2 105.6 25050 16350 Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 35 524/868 668/1113 5.0/3.2 168 0.67 2.6 0.7 129 410 50 387/641 494/822 6.8/4.4 183 0.73 2.6 0.8 122 390 70 268/443 343/568 9.8/6.3 207 0.83 2.6 0.8 115 370 95 193/320 248/410 13.3/8.5 229 0.92 2.6 0.9 110 350 120 153/253 196/325 17.2/11.0 249 1.00 2.6 0.9 106 340 150 124/206 159/265 21.2/13.5 266 1.06 4.3 1.0 103 330 185 99.1/164 128/211 26.6/17.0 289 1.16 4.3 1.0 100 320 240 75.4/125 98/161 34.9/22.3 318 1.27 4.3 1.1 95 300 300 60.1/100 80/130 43.8/28.0 348 1.39 4.3 1.2 93 290 400 47.0/77.8 64/102 57.3/36.6 388 1.53 5.8 1.3 87 280 500 36.6/60.5 51/81 72.3/46.2 422 1.67 5.8 1.4 78 250

slide 58:

Caledonian Medium V oltage Cables Three Core 18/30KV Um36KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 50 8.0 0.1 16 3.2 65 4340 3460 1.8 3.15 3.5 75 8950 8080 70 8.0 0.1 16 3.3 70 5220 3930 1.9 3.15 3.6 80 10150 8860 95 8.0 0.1 16 3.4 74 6240 4440 1.9 3.15 3.7 84 11390 9590 120 8.0 0.1 16 3.5 77 7180 4910 2.0 3.5 3.8 89 13200 10860 150 8.0 0.1 25 3.6 80 8220 5420 2.1 3.5 4.0 92 14520 11720 185 8.0 0.1 25 3.7 84 9540 6040 2.1 4.0 4.1 97 17020 13510 240 8.0 0.1 25 3.9 91 11720 7110 2.2 4.0 4.3 104 19810 15200 300 8.0 0.1 25 4.0 95 13790 8000 2.3 4.5 4.5 108 23310 17470 400 8.0 0.1 35 4.3 103 16820 9430 2.4 4.5 4.7 117 27010 19620 500 8.0 0.1 35 4.5 110 21550 12880 2.5 4.5 4.9 124 31130 22610 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Oveall Diameter Approx. Weight Nom. Bedding Thickness No of Steel tapes x nom tape thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 50 1.8 0.8 3.1 70.2 7490 6775 1.8 2x0.5 3.3 71.2 7300 6585 70 1.9 0.8 3.2 74.0 8590 7540 1.9 2x0.5 3.4 75.0 8390 7335 95 1.9 0.8 3.4 78.5 9990 8460 1.9 2x0.5 3.5 79.3 9740 8210 120 2.0 0.8 3.5 82.2 11250 9270 2.0 2x0.8 3.6 84.5 11845 9875 150 2.1 0.8 3.6 85.6 12510 10070 2.1 2x0.8 3.7 87.9 13120 10700 185 2.1 0.8 3.7 89.8 14155 11100 2.1 2x0.8 3.9 92.3 14850 11800 240 2.2 0.8 3.8 95.4 16740 12575 2.2 2x0.8 4.0 97.9 17480 13320 300 2.3 0.8 4.0 100.9 19310 14120 2.3 2x0.8 4.2 103.4 20080 14900 400 2.4 0.8 4.2 107.8 22840 16170 2.4 2x0.8 4.4 110.3 23660 17000 500 2.5 0.8 4.4 115.5 27200 18610 2.5 2x0.8 4.6 118.0 28080 19510 Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 50 387/641 494/822 6.8/4.4 142 0.85 2.6 1.0 134 430 70 268/443 343/568 9.8/6.3 159 0.95 2.6 1.0 127 400 95 193/320 248/410 13.3/8.5 175 1.05 2.6 1.1 121 390 120 153/253 196/325 17.2/11.0 189 1.13 2.6 1.1 117 370 150 124/206 159/265 21.2/13.5 201 1.21 4.3 1.2 113 360 185 99.1/164 128/211 26.6/17.0 217 1.3 4.3 1.2 109 350 240 75.4/125 98/161 34.9/22.3 237 1.42 4.3 1.3 104 330 300 60.1/100 80/130 43.8/28.0 258 1.55 4.3 1.4 101 320 400 47.0/77.8 64/102 57.3/36.6 282 1.69 5.8 1.5 96 290 500 36.6/60.5 51/81 72.3/46.2 302 1.79 5.8 1.6 78 250

slide 59:

57 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Three Core 21/35KV Um42KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 50 9.3 0.1 16 3.2 73.9 5320 4446 1.9 3.15 3.8 87.1 10970 10090 70 9.3 0.1 16 3.3 78.0 6166 4880 2.0 3.5 3.9 91.3 12220 10750 95 9.3 0.1 16 3.5 81.9 7144 5430 2.1 3.5 4.0 94.5 13560 11780 120 9.3 0.1 16 3.6 85.1 8232 6049 2.1 4.0 4.1 97.5 14880 13650 150 9.3 0.1 25 3.7 88.6 9273 6549 2.1 4.0 4.2 100.5 16150 14060 185 9.3 0.1 25 3.8 93.5 10845 7392 2.2 4.0 4.3 105.5 17840 14390 240 9.3 0.1 25 4.0 98.2 12675 8310 2.3 4.5 4.5 111.5 20410 15870 300 9.3 0.1 25 4.1 103.6 14960 9362 2.4 4.5 4.6 116.5 24100 18460 400 9.3 0.1 35 4.3 110.0 18055 10698 2.5 4.5 4.8 124.3 28680 20560 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Oveall Diameter Approx. Weight Nom. Bedding Thickness No of Steel tapes x nom tape thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 50 1.9 0.8 3.3 80.5 9825 8986 1.9 2x0.5 3.5 82.5 9625 8786 70 2.0 0.8 3.6 85.5 11015 9769 2.0 2x0.8 3.8 87.6 10825 9569 95 2.1 0.8 3.8 88.5 12360 10580 2.1 2x0.8 3.9 90.5 12116 10327 120 2.1 0.8 3.9 91.5 13900 11715 2.1 2x0.8 4.0 94.5 13306 11110 150 2.1 0.8 4.0 94.8 15160 12440 2.1 2x0.8 4.1 97.5 14550 11830 185 2.2 0.8 4.1 99.5 17500 13450 2.2 2x0.8 4.2 101.7 16810 12765 240 2.3 0.8 4.2 104.1 19390 14890 2.3 2x0.8 4.4 107.5 18650 14150 300 2.4 0.8 4.4 109.5 21970 16280 2.4 2x0.8 4.6 112.8 21200 15500 400 2.5 0.8 4.6 116.3 25600 18430 2.5 2x0.8 4.8 118.8 24780 17600 Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 50 387/641 494/822 6.8/4.4 135 0.91 2.6 1.1 140 450 70 268/443 343/568 9.8/6.3 151 1.01 2.6 1.1 134 415 95 193/320 248/410 13.3/8.5 166 1.11 2.6 1.2 126 405 120 153/253 196/325 17.2/11.0 179 1.21 2.6 1.2 123 385 150 124/206 159/265 21.2/13.5 189 1.29 4.3 1.3 118 375 185 99.1/164 128/211 26.6/17.0 202 1.38 4.3 1.3 114 365 240 75.4/125 98/161 34.9/22.3 221 1.49 4.3 1.4 109 345 300 60.1/100 80/130 43.8/28.0 240 1.65 4.3 1.5 105 335 400 47.0/77.8 64/102 57.3/36.6 267 1.75 5.8 1.6 101 305

slide 60:

Caledonian Medium V oltage Cables Three Core 26/35KV Um42KV Dimensional Data Unarmoured Cables Steel Round-Wire Armoured Cables Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km 50 10.5 0.1 16 3.4 79.7 5928 5053 1.9 3.5 4.0 93.5 12050 11150 70 10.5 0.1 16 3.5 83.6 6900 5634 2.0 4.0 4.1 97.5 13150 11850 95 10.5 0.1 16 3.6 87.2 7863 6131 2.1 4.0 4.2 101.5 14800 12950 120 10.5 0.1 16 3.8 90.7 8817 6634 2.2 4.0 4.4 105.5 16050 13800 150 10.5 0.1 25 3.9 94.1 10085 7361 2.3 4.5 4.5 108.5 17420 14640 185 10.5 0.1 25 4.0 99.1 11573 8120 2.3 4.5 4.6 112 19200 15700 240 10.5 0.1 25 4.1 103.6 13387 9023 2.4 4.5 4.7 117 21050 16800 300 10.5 0.1 25 4.3 109.2 15658 10060 2.5 4.5 4.8 122.5 24900 19100 400 10.5 0.1 35 4.5 115.6 19013 11657 2.6 4.5 5.1 129 29200 21560 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables Nom. Cross- Section Area Nom. Bedding Thickness Armour Wire Size Nom. Sheath Thickness Approx. Oveall Diameter Approx. Weight Nom. Bedding Thickness No of Steel tapes x nom tape thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL CU AL mm² mm mm mm mm kg/km mm mm mm mm kg/km 50 1.9 0.8 3.5 86.5 10880 9990 1.9 2x0.8 3.7 87.5 10690 9800 70 2.0 0.8 3.6 90.5 12000 10795 2.0 2x0.8 3.8 91.4 10800 10590 95 2.1 0.8 3.8 94.0 13360 11570 2.1 2x0.8 3.9 95.2 13110 11327 120 2.2 0.8 3.9 96.4 13705 12710 2.2 2x0.8 4.0 98.7 14300 12110 150 2.3 0.8 4.0 99.5 16160 13440 2.3 2x0.8 4.1 102.1 15550 12800 185 2.3 0.8 4.1 105.1 18505 14465 2.3 2x0.8 4.2 107.3 17810 13765 240 2.4 0.8 4.2 109.8 20390 15890 2.4 2x0.8 4.4 112.2 19650 15150 300 2.5 0.8 4.4 115.5 22970 17280 2.5 2x0.8 4.6 118.0 22200 16500 400 2.6 0.8 4.6 122.1 26600 19430 2.6 2x0.8 4.8 124.6 25780 18600 Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 50 387/641 494/822 6.8/4.4 131 0.97 2.6 1.2 146 470 70 268/443 343/568 9.8/6.3 145 1.07 2.6 1.2 139 430 95 193/320 248/410 13.3/8.5 158 1.18 2.6 1.3 132 420 120 153/253 196/325 17.2/11.0 169 1.26 2.6 1.3 128 400 150 124/206 159/265 21.2/13.5 178 1.36 4.3 1.4 123 390 185 99.1/164 128/211 26.6/17.0 185 1.44 4.3 1.4 118 380 240 75.4/125 98/161 34.9/22.3 203 1.57 4.3 1.5 113 360 300 60.1/100 80/130 43.8/28.0 219 1.72 4.3 1.6 109 350 400 47.0/77.8 64/102 57.3/36.6 245 1.85 5.8 1.7 105 320

slide 61:

59 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to IEC 60502 Current Rating for Three Core 1.8/3KVUm7.2 KV to 26/35KVUm42KV XLPE Insulation Unarmored Armored Nom. Cross- Section Area Buried direct in Ground Laid in Single Way Duct Laid in Air Buried direct in Ground Laid in Single Way Duct Laid in Air CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A 10 76 53 62 42 87 62 76 53 63 43 88 63 16 101 78 87 67 109 84 101 78 88 68 110 85 25 129 100 112 87 142 110 129 100 112 87 143 111 35 153 119 133 103 170 132 154 119 134 104 172 133 50 181 140 158 122 204 158 181 140 158 123 205 159 70 221 171 193 150 253 196 220 171 194 150 253 196 95 262 203 231 179 304 236 263 204 232 180 307 238 120 298 232 264 205 351 273 298 232 264 206 352 274 150 334 260 297 231 398 309 332 259 296 231 397 309 185 377 294 336 262 455 355 374 293 335 262 453 354 240 434 340 390 305 531 415 431 338 387 304 529 415 300 489 384 441 346 606 475 482 380 435 343 599 472 400 553 438 501 398 696 552 541 432 492 393 683 545 500 613 498 541 451 786 652 601 492 532 446 773 645 630 663 568 591 501 896 762 651 562 582 496 883 755 Current Rating for Three Core 1.8/3KVUm7.2 KV to 26/35KVUm42KV EPR Insulation Unarmored Armored Nom. Cross- Section Area Buried direct in Ground Laid in Single Way Duct Laid in Air Buried direct in Ground Laid in Single Way Duct Laid in Air CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A 10 73 51 59 40 82 58 73 51 60 41 82 59 16 98 76 84 65 104 80 98 76 85 66 104 81 25 125 97 109 84 135 105 125 97 109 85 136 105 35 150 116 130 101 164 127 150 116 131 101 164 127 50 176 137 154 119 195 151 177 137 155 120 197 153 70 216 167 189 147 243 189 216 168 190 147 244 190 95 258 200 227 176 296 229 257 200 227 176 296 230 120 292 227 258 201 339 263 292 227 259 201 339 264 150 328 255 291 226 385 299 327 254 291 226 385 300 185 371 289 330 257 441 343 368 288 328 257 439 343 240 429 335 384 300 519 406 424 332 381 299 513 402 300 482 378 434 340 590 462 475 374 429 338 583 459 400 545 432 494 392 678 538 534 426 485 387 666 530 500 605 492 534 445 768 638 594 486 525 440 756 630 630 655 562 584 495 878 749 644 556 575 490 862 741 ▓ Current Rating Conditions: Ground Temperature: 20°C Ambient Temperature air: 30°C Depth of Soil: 0.8 m Thermal Resistance of Soil: 1.5K•m/W

slide 62:

IV I II III IV V Medium Voltage Cables to VDE 0276 Single Core Cables to VDE 0276 Three Core Cables to VDE 0276 Caledonian Medium Voltage Cables

slide 63:

61 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Single Core Cables to VDE 0276 ▓ APPLICATIONS: The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.8/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations indoors and in cable ducts outdoors underground and in water as well as for installation on cable trays for industries switchboards and power stations. ▓ STANDARD: DIN VDE 0276 Part 620-622 HD 620 S1 ▓ CONSTRUCTION: Conductor: Stranded compacted circular copper or aluminium conductors according to IEC 60228 class 2 / VDE 0276 class 2 / VDE 0295 HD 383. All internal interstices of the conductor are flled with water blocking compound to prevent ingress of water through conductor during storage handing installation and operation of the cable. Conductor Screen: The conductor screen consists of an extruded layer of non metallic semi-conducting compound frmly bonded to the insulation to exclude all air voids. The screen has a minimum thickness of 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C. Insulation: Insulation is of extruded XLPE compound type 2XI1 according to DIN VDE 0207 part 22 and HD 620.1 with high degree of cross-linking free from contaminants air voids and heat resistant by dry cured process. The nominal insulation wall thickness is shown in table 1. PVC/PE/LSZH Over Sheath Aluminium Wire Armour optional XLPE Insulation Conductor Conductor Screen Insulation Screen Metallic Screen PVC/PE/LSZH Separation Sheath optional Binder

slide 64:

Caledonian Medium V oltage Cables Table 1. Insulation Thickness Nom. Cross Section Area Insulation Thickness at Nom. Voltage 3.6/6KVUm7.2KV 6/10KVUm12KV 8.7/15KVUm17.5KV 12/20KVUm24KV 18/30KVUm36KV mm² mm mm mm mm mm 35 2.5 3.4 4.5 5.5 - 50 2.5 3.4 4.5 5.5 8.0 70 2.5 3.4 4.5 5.5 8.0 95 2.5 3.4 4.5 5.5 8.0 120 2.5 3.4 4.5 5.5 8.0 150 2.5 3.4 4.5 5.5 8.0 185 2.5 3.4 4.5 5.5 8.0 240 2.6 3.4 4.5 5.5 8.0 300 2.8 3.4 4.5 5.5 8.0 400 3.0 3.4 4.5 5.5 8.0 Insulation Screen: The insulation screen consists of extruded non metallic semi-conducting compound extruded over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating.The minimum thickness is 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C. The screen is tightly ftted to the insulation to exclude all air voids and can be easily hand stripped on site. Conducting Water Blocking Layer: The insulation screen may be coverd by semi- conductive water blocking tape which will swell up under the infuence of moisture of water to ensure longitudinal watertightness. Metallic Screen: Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires copper tape with minimum thickness of 0.1mm is applied helically with overlap. Total cross section of metallic screen layer is shown in table 2. The screen can withstand fault current to earth of 1000 A for one second at maximum temperature of 160°C. Minimum cross section of concentric conductor is according to DIN VDE 0273 0276 as shown. Table 2. Minimum Total Cross Section of Metallic Screen Nominal Cross-Section Area of Cable Minimum Cross-Section of Metallic Screen DC Resistance of the Copper Wire Screen mm² mm² mm Up to 120 16 1.06 150-300 25 0.72 400-630 35 0.51 800-1000 50 0.35 Separator / Water Blocking Layer: The metallic screen may be covered by non-conducting water blocking tape which will swell up under the influence of moisture of water to ensure longitudinal watertightness. Separation Sheath for armoured cable: The separation sheath comprises a layer of extruded PVC PE or LSZH applied under the armour. Thickness of separation sheath as shown in table 3.

slide 65:

63 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Table 3. Separation Sheath Thickness Core Diameter Approx.Thickess of Inner Sheath mm mm 35 45 1.4 45 60 1.6 60 80 1.8 80 - 2.0 Armour for armoured cable: The armour consists of round aluminium wire armour applied helically over an extruded separation sheath. Table 4. Round Armour Wire Diameter Fictitious Diameter under the Armour Armour Wire Diameter mm mm - 10 0.8 10 15 1.25 15 25 1.6 25 35 2.0 35 60 2.5 60 - 3.15 Over Sheath: Overall sheath comprises a layer of extruded PE compound DMP2 according to HD620.1 and 2YM3 type to DIN VDE 0276 Part 3 or PVC compound DMV6 according to HD620.1 and YM5 to DIN VDE 0276 Part 6. LSZH can be offered as an option. Normal wall thickness is 2.5mm for 1/500mmsq 18/30KV wall thickness is 2.6mm suitable for exposure to sun-light or other local atmospheric environments and for the operating temperature of the cable. ▓ PHYSICAL PROPERTIES: Operating Temperature: up to 90°C Temperature Range: -5°C PVC or LSZH sheath -20°C PE sheath Short Circuit Temperature: 250°C short circuit duration up to 5 seconds Bending Radius: 15 x OD Cable without metal sheath 30 x OD Cable with aluminium sheath Table 5. Nominal /Operating /Testing Voltages Nominal Voltage Uo/U Operating Voltage max Testing Voltage 3.6/6KV 8KV 10KV 6/10KV 12KV 15KV 8.7/15KV 18KV 22.5KV 12/20KV 24KV 30KV 18/30KV 36KV 45KV

slide 66:

Caledonian Medium V oltage Cables ▓ TYPE CODES: Cores N According to VDE Standard No abbreviation for copper conductor A Aluminium Conductor 2X XLPE Insulation Y PVC Insulation Screen S Screen of copper wires and copper tape helically wound. SE Screen of copper wire plus copper tape over each individual cores helically wound F Longitudinally waterproof screen. Concentric Conductor Screen C Concentric conductor screen of copper wires and copper tape helically wound. CE Concentric conductor screen of copper wire plus copper tape over each individual cores helically wound. Jacket 2Y PE Jacket Y PVC Jacket H LSZH Jacket

slide 67:

65 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Single Core 1.8/3KV Um3.6KV Dimensional Data Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Nom. Overall Diameter Approx. Weight N2XSY/ N2XSH CU NA2XSY/ NA2XSH AL N2XS2Y CU NA2XS2Y AL N2XSF2Y CU NA2XSF 2Y AL mm² mm mm mm² mm mm kg/km kg/km kg/km kg/km kg/km kg/km 25 2.0 0.1 16 1.4 13 500 180 480 140 500 230 35 2.0 0.1 16 1.4 14 620 280 600 240 620 330 50 2.0 0.1 16 1.4 15 700 380 750 290 750 430 70 2.0 0.1 16 1.5 17 900 480 800 380 1000 560 95 2.0 0.1 16 1.5 19 1200 590 1050 460 1300 670 120 2.0 0.1 16 1.6 21 1450 700 1300 550 1500 800 150 2.0 0.1 25 1.6 22 1700 800 1550 650 1800 900 185 2.0 0.1 25 1.7 24 2050 850 1900 750 2150 950 240 2.0 0.1 25 1.8 27 2550 1050 2350 900 2650 1150 300 2.0 0.1 25 1.8 29 3150 1250 2950 1050 3250 1350 400 2.0 0.1 35 1.9 32 3950 1550 3800 1450 4100 1650 500 2.2 0.1 35 2.0 35 5000 2000 4800 1800 5200 2150 630 2.4 0.1 35 2.2 38 6200 2200 6300 2100 6400 2350 800 2.6 0.1 35 2.3 44 8000 2900 7900 2800 8200 3050 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/ m 25 727/1200 929/1538 3.6/2.3 222 0.32 2.6 0.3 131 185 345 535 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 251 0.35 2.6 0.4 122 178 327 524 679 1121 695 1131 50 387/641 494/822 6.8/4.4 281 0.39 2.6 0.4 116 172 313 514 511 834 527 844 70 268/443 343/568 9.8/6.3 341 0.45 2.6 0.5 110 165 300 495 364 583 386 597 95 193/320 248/410 13.3/8.5 397 0.50 2.6 0.5 104 160 287 485 272 427 300 446 120 153/253 196/325 17.2/11.0 430 0.55 2.6 0.6 104 159 280 475 225 345 257 367 150 124/206 159/265 21.2/13.5 464 0.59 4.3 0.6 100 156 274 465 193 287 229 313 185 99.1/164 128/211 26.6/17.0 513 0.65 4.3 0.7 98 154 267 459 165 237 206 267 240 75.4/125 98/161 34.9/22.3 573 0.70 4.3 0.9 94 150 260 455 140 191 185 226 300 60.1/100 80/130 43.8/28.0 652 0.72 4.3 1.0 91 147 253 445 128 163 174 203 400 47.0/77.8 64/102 57.3/36.6 727 0.75 5.8 1.1 90 147 248 435 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 754 0.79 5.8 1.2 89 145 245 425 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 786 0.87 5.8 1.3 86 143 243 415 97 110 151 160

slide 68:

Caledonian Medium V oltage Cables SIngle Core 3.6/6KV Um7.2 KV Dimensional Data Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Nom. Overall Diameter Approx. Weight N2XSY/ N2XSH CU NA2XSY/ NA2XSH AL N2XS2Y CU NA2XS2Y AL N2XSF2Y CU NA2XSF2Y AL mm² mm mm mm² mm mm kg/km kg/km kg/km kg/km kg/km kg/km 25 2.5 0.1 16 1.5 18 700 480 600 550 700 560 35 2.5 0.1 16 1.6 20 820 580 800 560 900 660 50 2.5 0.1 16 1.6 21 1000 680 900 570 1050 750 70 2.5 0.1 16 1.7 23 1200 770 1100 650 1300 850 95 2.5 0.1 16 1.7 24 1500 890 1350 760 1550 990 120 2.5 0.1 16 1.8 26 1850 1000 1700 850 1900 1150 150 2.5 0.1 25 1.8 27 2100 1100 1950 1050 2200 1250 185 2.5 0.1 25 1.9 29 2450 1250 2300 1200 2550 1300 240 2.6 0.1 25 1.9 32 3050 1550 2850 1400 3150 1650 300 2.8 0.1 25 2.0 35 3650 1850 3450 1650 3750 1950 400 3.0 0.1 35 2.1 38 4550 2250 4400 2050 4700 2350 500 3.2 0.1 35 2.3 42 5700 2700 5500 2500 5900 2850 630 3.2 0.1 35 2.4 48 7090 3020 6890 2820 7290 3200 800 3.2 0.1 35 2.5 52 8900 3700 8700 3500 9100 3850 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 25 727/1200 927/1538 3.6/2.3 262 0.32 2.6 0.4 142 196 400 590 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 291 0.35 2.6 0.5 133 187 390 580 679 1121 695 1131 50 387/641 494/822 6.8/4.4 321 0.39 2.6 0.5 121 179 380 570 511 834 527 844 70 268/443 343/568 9.8/6.3 371 0.45 2.6 0.6 115 173 370 550 364 583 386 597 95 193/320 248/410 13.3/8.5 417 0.50 2.6 0.6 110 168 350 540 272 427 300 446 120 153/253 196/325 17.2/11.0 459 0.55 2.6 0.7 107 165 340 520 225 345 257 367 150 124/206 159/265 21.2/13.5 494 0.59 4.3 0.7 103 161 330 510 193 287 229 313 185 99.1/164 128/211 26.6/17.0 543 0.65 4.3 0.8 100 158 320 500 165 237 206 267 240 75.4/125 98/161 34.9/22.3 583 0.70 4.3 0.9 97 155 310 490 140 191 185 226 300 60.1/100 80/130 43.8/28.0 602 0.72 4.3 1.0 95 153 300 490 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 627 0.75 5.8 1.1 92 150 290 480 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 654 0.79 5.8 1.2 90 147 290 470 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 726 0.87 5.8 1.3 87 145 280 460 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 786 0.91 5.8 1.4 85 143 270 460 92 101 147 153 For capacitance charging current values multiply values shown by 1.2 for EPR insulated cables.

slide 69:

67 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Single Core 6/10KV Um12 KV Dimensional Data Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Nom. Overall Diameter Approx. Weight N2XSY/ N2XSH CU NA2XSY/ NA2XSH AL N2XS2Y CU NA2XS2Y AL N2XF2Y CU NA2XSF2Y AL mm² mm mm mm mm mm kg/km kg/km kg/km kg/km kg/km kg/km 25 3.4 0.1 16 1.6 25 820 580 720 550 900 650 35 3.4 0.1 16 1.6 25 920 680 900 570 980 750 50 3.4 0.1 16 1.7 26 1100 780 950 670 1150 850 70 3.4 0.1 16 1.7 28 1300 870 1200 750 1400 950 95 3.4 0.1 16 1.8 30 1600 990 1450 860 1650 1100 120 3.4 0.1 16 1.8 32 1950 1100 1800 950 2050 1250 150 3.4 0.1 25 1.9 33 2200 1200 2050 1150 2300 1350 185 3.4 0.1 25 1.9 34 2550 1350 2400 1300 2650 1500 240 3.4 0.1 25 2.0 36 3150 1650 2950 1500 3250 1750 300 3.4 0.1 25 2.1 38 3750 1950 3550 1750 3850 2050 400 3.4 0.1 35 2.2 43 4650 2350 4500 2150 4800 2450 500 3.4 0.1 35 2.3 45 5800 2800 5700 2600 6000 2950 630 3.4 0.1 35 2.4 50 7300 3100 7010 2950 7500 3300 800 3.4 0.1 35 2.5 50 9100 3900 8900 3700 9300 4000 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 25 727/1200 927/1538 3.6/2.3 208 0.42 2.6 0.5 144 210 460 660 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 229 0.46 2.6 0.6 136 200 440 640 679 1121 695 1131 50 387/641 494/822 6.8/4.4 252 0.50 2.6 0.6 131 195 420 620 511 834 527 844 70 268/443 343/568 9.8/6.3 288 0.58 2.6 0.7 122 188 390 600 364 583 386 597 95 193/320 248/410 13.3/8.5 323 0.65 2.6 0.7 122 182 390 580 272 427 300 446 120 153/253 196/325 17.2/11.0 353 0.71 2.6 0.8 116 172 370 550 225 345 257 367 150 124/206 159/265 21.2/13.5 380 0.76 4.3 0.8 110 166 350 530 193 287 229 313 185 99.1/164 128/211 26.6/17.0 416 0.83 4.3 0.9 107 166 340 530 165 237 206 267 240 75.4/125 98/161 34.9/22.3 460 0.92 4.3 0.9 104 163 330 520 140 191 185 226 300 60.1/100 80/130 43.8/28.0 506 1.01 4.3 1.0 100 157 320 500 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 561 1.12 5.8 1.1 94 154 300 490 113 141 164 184 500 36.6/60.5 51/81.0 72.3/46.2 619 1.24 5.8 1.2 91 151 290 480 105 124 158 171 630 28.3/46.9 42/64.0 91.2/58.3 698 1.37 5.8 1.3 91 148 290 470 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 780 1.39 5.8 1.4 88 144 280 470 92 101 147 153

slide 70:

Caledonian Medium V oltage Cables Singke Core 8.7/15KV Um17.5KV Dimensional Data Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Nom. Overall Diameter Approx. Weight N2XSY/ N2XSH CU NA2XSY/ NA2XSH AL N2XS2Y CU NA2XS2Y AL N2XSF2Y CU NA2XSF2Y AL mm² mm mm mm mm mm kg/km kg/km kg/km kg/km kg/km kg/km 25 4.5 0.1 16 1.7 26 900 600 880 500 900 700 35 4.5 0.1 16 1.7 26 1020 700 1000 600 1060 800 50 4.5 0.1 16 1.7 27 1200 880 1050 770 1250 950 70 4.5 0.1 16 1.8 29 1400 970 1300 850 1500 1050 95 4.5 0.1 16 1.8 31 1700 1090 1550 960 1750 1200 120 4.5 0.1 16 1.9 32 2050 1200 1900 1150 2100 1300 150 4.5 0.1 25 1.9 33 2300 1400 2150 1250 2400 1500 185 4.5 0.1 25 2.0 35 2650 1650 2500 1400 2750 1750 240 4.5 0.1 25 2.1 37 3250 1750 3050 1600 3350 1850 300 4.5 0.1 25 2.1 39 3850 2050 3650 1850 3950 2150 400 4.5 0.1 35 2.3 43 4850 2550 4700 2250 5000 2550 500 4.5 0.1 35 2.3 45 5900 2900 5700 2600 6100 3050 630 4.5 0.1 35 2.5 51 7500 3200 7200 3100 8000 3400 800 4.5 0.1 35 2.6 51 9300 4200 9100 4000 9500 4300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Spaced Flat Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 25 727/1200 927/1538 3.6/2.3 171 0.47 2.6 0.6 150 210 480 680 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 187 0.51 2.6 0.6 141 207 460 660 679 1121 695 1131 50 387/641 494/822 6.8/4.4 204 0.57 2.6 0.7 138 195 440 640 511 834 527 844 70 268/443 343/568 9.8/6.3 232 0.63 2.6 0.7 132 188 420 600 364 583 386 597 95 193/320 248/410 13.3/8.5 258 0.71 2.6 0.8 126 182 400 580 272 427 300 446 120 153/253 196/325 17.2/11.0 281 0.74 2.6 0.8 119 179 380 570 225 345 257 367 150 124/206 159/265 21.2/13.5 301 0.79 4.3 0.9 113 176 360 560 193 287 229 313 185 99.1/164 128/211 26.6/17.0 329 0.87 4.3 0.9 110 170 350 540 165 237 206 267 240 75.4/125 98/161 34.9/22.3 363 0.96 4.3 1.0 107 166 340 530 140 191 185 226 300 60.1/100 80/130 43.8/28.0 398 1.03 4.3 1.1 104 160 330 510 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 439 1.17 5.8 1.2 97 157 310 500 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 483 1.28 5.8 1.3 94 154 300 490 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 534 1.42 5.8 1.4 91 151 290 480 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 590 1.61 5.8 1.4 91 147 290 470 92 101 147 153

slide 71:

69 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Single Core 12/20KV Um24KV Dimensional Data Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Nom. Overall Diameter Approx. Weight N2XSY/ N2XSH CU NA2XSY/ NA2XSH AL N2XS2Y CU NA2XS2Y AL N2XSF2Y CU NA2XSF2Y AL mm² mm mm mm mm mm kg/km kg/km kg/km kg/km kg/km kg/km 25 5.5 0.1 16 1.8 29 1000 750 900 630 1100 850 35 5.5 0.1 16 1.8 30 1100 850 1050 730 1200 950 50 5.5 0.1 16 1.8 31 1250 970 1150 830 1350 1050 70 5.5 0.1 16 1.9 33 1500 1100 1350 920 1600 1200 95 5.5 0.1 16 1.9 34 1800 1200 1650 1050 1900 1300 120 5.5 0.1 16 2.0 35 2150 1350 1900 1150 2250 1450 150 5.5 0.1 25 2.0 37 2400 1500 2250 1350 2500 1650 185 5.5 0.1 25 2.1 38 2800 1700 2600 1550 2900 1800 240 5.5 0.1 25 2.1 42 3400 1900 3200 1750 3500 2050 300 5.5 0.1 25 2.2 43 4000 2200 3800 2000 4150 2300 400 5.5 0.1 35 2.3 44 4950 2600 4750 2400 5100 2800 500 5.5 0.1 35 2.4 46 6050 3000 5800 2800 6200 3200 630 5.5 0.1 35 2.5 50 8150 3600 8050 3400 8300 3750 800 5.5 0.1 35 2.6 53 9600 4400 9450 4200 9800 4300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Spaced Trefoil Flat Spaced Trefoil Flat Spaced CU AL CU AL mm² µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/m 25 727/1200 927/1538 3.6/2.3 142 0.62 2.6 0.6 162 214 490 680 936 1544 952 1554 35 524/868 668/1113 5.0/3.2 162 0.65 2.6 0.7 150 207 470 660 679 1121 695 1131 50 387/641 494/822 6.8/4.4 177 0.71 2.6 0.8 141 201 450 640 511 834 527 844 70 268/443 343/568 9.8/6.3 200 0.80 2.6 0.8 135 195 430 620 364 583 386 597 95 193/320 248/410 13.3/8.5 222 0.89 2.6 0.9 129 188 410 600 272 427 300 446 120 153/253 196/325 17.2/11.0 241 0.96 2.6 0.9 122 182 390 580 225 345 257 367 150 124/206 159/265 21.2/13.5 257 1.03 4.3 1.0 116 176 370 560 193 287 229 313 185 99.1/164 128/211 26.6/17.0 280 1.12 4.3 1.0 116 173 370 550 165 237 206 267 240 75.4/125 98/161 34.9/22.3 307 1.23 4.3 1.1 110 170 350 540 140 191 185 226 300 60.1/100 80/130 43.8/28.0 336 1.34 4.3 1.2 107 166 340 530 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 370 1.48 5.8 1.3 100 160 320 510 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 406 1.62 5.8 1.4 97 154 310 490 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 449 1.80 5.8 1.5 94 151 300 480 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 490 1.85 5.8 1.6 91 151 290 480 92 101 147 153

slide 72:

Caledonian Medium V oltage Cables Single Core 18/30KV Um36KV Dimensional Data Nom. Cross- Section Area Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Nom. Sheath Thickness Nom. Overall Diameter Approx. Weight N2XSY/ N2XSH CU NA2XSY/ NA2XSH AL N2XS2Y CU NA2XS2Y AL N2XSF2Y CU NA2XSF2Y AL mm² mm mm mm mm mm kg/km kg/km kg/km kg/km kg/km kg/km 25 8.0 0.1 16 1.9 30 1300 1050 1100 900 1400 1150 35 8.0 0.1 16 1.9 30 1400 1150 1200 1000 1500 1250 50 8.0 0.1 16 2.0 35 1550 1250 1350 1100 1650 1350 70 8.0 0.1 16 2.0 37 1750 1350 1600 1200 1900 1450 95 8.0 0.1 16 2.1 39 2050 1500 1900 1300 2150 1600 120 8.0 0.1 16 2.1 41 2350 1600 2150 1450 2450 1750 150 8.0 0.1 25 2.2 42 2700 1850 2550 1650 2750 1950 185 8.0 0.1 25 2.2 44 3100 2000 2900 1800 3150 2150 240 8.0 0.1 25 2.3 46 3700 2250 3500 2050 3800 2400 300 8.0 0.1 25 2.4 49 4350 2550 4150 2300 4400 2700 400 8.0 0.1 35 2.5 52 5350 3000 5100 2750 5450 3200 500 8.0 0.1 35 2.6 54 6450 3450 6200 3150 6550 3650 630 8.0 0.1 35 2.7 59 8300 3780 8100 3600 8600 4100 800 8.0 0.1 35 2.8 59 9900 4500 9700 4320 10300 4800 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen 1 sec Short Circuit Rating of Copper Tape Screen 1 sec Reactance Inductance Impedance Trefoil Flat Trefoil Flat Trefoil Flat spaced CU AL CU AL mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/ m 25 727/1200 927/1538 3.6/2.3 121 0.71 2.6 0.9 159 229 530 720 686 1247 759 1146 50 387/641 494/822 6.8/4.4 138 0.83 2.6 1.0 151 214 480 680 511 834 527 844 70 268/443 343/568 9.8/6.3 154 0.92 2.6 1.0 144 201 460 640 364 583 386 597 95 193/320 248/410 13.3/8.5 169 1.01 2.6 1.1 138 195 440 620 272 427 300 446 120 153/253 196/325 17.2/11.0 183 1.10 2.6 1.1 132 188 420 600 225 345 257 367 150 124/206 159/265 21.2/13.5 194 1.16 4.3 1.2 126 182 400 580 193 287 229 313 185 99.1/164 128/211 26.6/17.0 210 1.26 4.3 1.2 122 182 390 580 165 237 206 267 240 75.4/125 98/161 34.9/22.3 229 1.37 4.3 1.3 119 176 380 560 140 191 185 226 300 60.1/100 80/130 43.8/28.0 249 1.49 4.3 1.4 113 173 360 550 126 163 174 203 400 47.0/77.8 64/102 57.3/36.6 273 1.64 5.8 1.5 107 163 340 520 113 141 164 184 500 36.6/60.5 51/81 72.3/46.2 298 1.79 5.8 1.6 104 163 330 520 105 124 158 171 630 28.3/46.9 42/64 91.2/58.3 327 1.96 5.8 1.7 99 160 320 510 97 110 151 160 800 22.1/36.7 35/55 114.4/75.0 350 1.98 5.8 1.8 98 154 310 490 92 101 147 153

slide 73:

71 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Current Rating for Single Core 1.8/3KVUm3.6KV to 18/30KVUm36KV XLPE Insulation Nom. Cross- Section Area Buried direct in Ground Laid in Single Way Duct Laid in Air Trefoil Flat spaced Trefoil Flat touching Trefoil Flat Touching Flat spaced CU AL CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A A 10 84 59 87 62 78 55 98 56 103 75 106 77 122 88 16 109 84 113 88 103 80 104 81 125 97 128 99 150 116 25 140 108 144 112 132 102 133 103 163 127 167 130 196 153 35 166 129 172 134 157 122 159 123 198 154 203 157 238 185 50 196 152 203 157 186 144 188 146 238 184 243 189 286 222 70 239 186 246 192 227 176 229 178 296 230 303 236 356 278 95 285 221 293 229 271 210 274 213 361 280 369 287 434 338 120 323 252 332 260 308 240 311 242 417 324 426 332 500 391 150 361 281 366 288 343 267 347 271 473 368 481 376 559 440 185 406 317 410 324 387 303 391 307 543 424 550 432 637 504 240 469 367 470 373 447 351 453 356 641 502 647 511 745 593 300 526 414 524 419 504 397 510 402 735 577 739 586 846 677 400 590 470 572 466 564 451 571 457 845 673 837 676 938 769 500 650 530 672 546 604 504 661 537 935 773 938 776 1118 919 630 700 600 882 646 654 554 771 617 1045 883 1048 886 1318 1089 800 750 660 1002 756 694 594 871 717 1145 983 1148 986 1528 1279 1000 800 720 1112 856 724 644 971 807 1235 1083 1238 1086 1738 1469

slide 74:

Caledonian Medium V oltage Cables Three Core Cables to VDE 0276 ▓ APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations indoors and in cable ducts outdoors underground and in water as well as for installation on cable trays for industries switchboards and power stations. ▓ STANDARD: DIN VDE 0276 Part 620-622 HD 620 S1 ▓ CONSTRUCTION: Conductor: Stranded compacted circular copper or aluminium conductors according to IEC 60228 class 2 / VDE 0276 class 2 / VDE 0295 HD 383. All internal interstices of the conductor are flled with water blocking compound to prevent ingress of water through conductor during storage handing installation and operating of the cable. Conductor Screen: The conductor screen consists of an extruded layer of non metallic semi-conducting compound frmly bonded to the insulation to exclude all air voids. The screen has a minimum thickness of 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C. Insulation: Insulation is of extruded XLPE compound type 2XI1 according to DIN VDE 0207 part 22 and HD 620.1 with high degree of cross-linking free from contaminants air voids and heat resistant by dry cured process. The nominal insulation wall thickness is shown in table 1. PVC/PE/LSZH Over Sheath PVC/PE/LSZH Separation Sheath optional Armour optional Binder Conductor Screen Conductor XLPE Insulation Insulation Screen Metallic Screen

slide 75:

73 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Table 1. Insulation Thickness Nom. Cross-Section Area Insulation Thickness at Nom. Voltage 3.6/6KV Um7.2KV 6/10KV Um12KV 8.7/15KV Um17KV 12/20KV Um24KV 18/30KV Um36KV mm² mm mm mm mm mm XLPE XLPE XLPE XLPE XLPE 35 2.5 3.4 4.5 5.5 - 50 2.5 3.4 4.5 5.5 8.0 70 2.5 3.4 4.5 5.5 8.0 95 2.5 3.4 4.5 5.5 8.0 120 2.5 3.4 4.5 5.5 8.0 150 2.5 3.4 4.5 5.5 8.0 185 2.5 3.4 4.5 5.5 8.0 240 2.6 3.4 4.5 5.5 8.0 300 2.8 3.4 4.5 5.5 8.0 400 3.0 3.4 4.5 5.5 8.0 Insulation Screen: The insulation screen consists of extruded non metallic semi-conducting compound extruded over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. The minimum thickness is 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C. The screen is tightly ftted to the insulation to exclude all air voids and can be easily hand stripped on site. Conducting Water Blocking Layer: The insulation screen may be covered by semi- conductive water blocking tape which will swell up under the infuence of moisture of water to ensure longitudinal watertightness. Metallic Screen: Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires copper tape with minimum thickness of 0.1mm is applied helically with overlap. Total cross section of metallic screen layer is shown in table 2. The screen can withstand fault current to earth of 1000 A for one second at maximum temperature of 160°C. Minimum cross section of concentric conductor is according to DIN VDE 0273 0276 as shown. Table 2. Minimum Total Cross Section of Metallic Screen Nominal Cross-Section Area of Cable Minimum Cross-Section of Metallic Screen DC Resistance of the Copper Wire Screen mm² mm² mm Up to 120 16 1.06 150-300 25 0.72 400-630 35 0.51 800-1000 50 0.35 Separator / Water Blocking Layer: The metallic screen may be covered by non-conducting water blocking tape which will swell up under the influence of moisture of water to ensure longitudinal watertightness. Separation Sheath for armoured cable: The separation sheath comprises a layer of extruded PVC PE or LSZH applied under the armour. Thickness of separation sheath is shown in table 3.

slide 76:

Caledonian Medium V oltage Cables Table 3. Separation Sheath Thickness Cores Diameter Approx.Thickess of Inner Sheath mm mm 35 45 1.4 45 60 1.6 60 80 1.8 80 - 2.0 Armourfor armoured cable: The armour consists of: 1 Double layers of galvanized steel tape are applied helically with proper inner overlapping over an extruded separation sheath. Thickness of the steel tape is shown in table 4. Tabel 4. Galvanized Steel Tape Thickness Inner Diameter Thickness of Galvanized Steel Tape mm mm - 30 0.2 30 70 0.5 70 - 0.8 2 Galvanized fat steel wires with thickness of 0.8 mm are applied helically over the surface of inner sheath with minimum of 90 coverage. And galvanized Steel tape with nominal thickness of 0.3 mm is applied helically with 50 coverage to cover the surface of the fat wires. Over Sheath: Overall sheath comprises a layer of extruded PE compound DMP2 according to HD620.1 and 2YM3 type to DIN VDE 0276 Part 3 or PVC compound DMV6 according to HD620.1 and YM5 to DIN VDE 0276 Part 6. LSZH can be offered as an option. Normal wall thickness is 2.5mm for 1/500mmsq 18/30KV wall thickness is 2.6mm suitable for exposure to sun-light or other local atmospheric environments and for the operating temperature of the cable. ▓ PHYSICAL PROPERTIES: Operating Temperature: up to 90°C Temperature Range: -5°C PVC or LZSH sheath -20°C PE sheath Short Circuit Temperature: 250°C short circuit duration up to 5 seconds Bending Radius: 15 x OD Cable without metal sheath 30 x OD Cable with aluminium sheath Table 5. Nominal /Operating /Testing Voltages Nominal Voltage Uo/U Operating Voltage Um Testing Voltage 3.6/6KV 8KV 12.5KV 6/10KV 12KV 21KV 8.7/15KV 18KV 30.5KV 12/20KV 24KV 42KV 18/30KV 36KV 63KV

slide 77:

75 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 ▓ TYPE CODES: Conductor N According to VDE Standard No abbreviation for copper conductor A Aluminium conductor - Copper conductor Insulation 2X XLPE Screen C Concentric conductor of copper CE Concentric conductor of copper over each individual core S Screen of copper wires copper tape helically wound SE Screen of copper wires over each individual cores G Longitudinally waterproof Armour F Armour of galvanized fat steel wirestrip Gb Counter Helix of galvanized steel tape B Steel tape armouring R Armour of galvanized round steel wire Ra Armour of round aluminium wire Sheath 2Y PE Y PVC H LSZH K Lead sheath KL Aluminium sheath

slide 78:

Caledonian Medium V oltage Cables Three Core 3.6/6KV Um7.2KV N2XSEY NA2XSEY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm kg/km kg/km 25 6.05 2.5 0.1 16 12.5 1.5 37 2100 1600 35 7.10 2.5 0.1 16 13.5 1.6 39 2500 1800 50 8.25 2.5 0.1 16 14.7 1.6 42 3000 2100 70 9.90 2.5 0.1 16 16.3 1.7 46 3800 2500 95 11.7 2.5 0.1 16 18.1 1.7 50 4800 3000 120 13.1 2.5 0.1 16 19.5 1.8 53 5800 3500 150 14.3 2.5 0.1 25 20.7 1.8 56 6700 3900 185 16.3 2.5 0.1 25 22.7 1.9 60 8100 4600 240 18.7 2.6 0.1 25 25.3 1.9 66 10200 5600 300 20.9 2.8 0.1 25 27.9 2.0 72 12500 6700 400 23.7 3.0 0.1 35 31.1 2.1 80 15600 8200 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Three Core 3.6/6KV Um7.2KV Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 25 6.05 2.5 0.1 16 12.5 0.5 2.2 39 2800 2300 35 7.10 2.5 0.1 16 13.5 0.5 2.3 42 3200 2600 50 8.25 2.5 0.1 16 14.7 0.5 2.4 45 3800 2900 70 9.90 2.5 0.1 16 16.3 0.5 2.5 49 4700 3400 95 11.7 2.5 0.1 16 18.1 0.5 2.6 53 5800 4000 120 13.1 2.5 0.1 16 19.5 0.5 2.7 56 6800 4600 150 14.3 2.5 0.1 25 20.7 0.5 2.8 59 7900 5100 185 16.3 2.5 0.1 25 22.7 0.8 2.9 64 9400 5900 240 18.7 2.6 0.1 25 25.3 0.8 3.1 70 11700 7000 300 20.9 2.8 0.1 25 27.9 0.8 3.3 76 14100 8300 400 23.7 3.0 0.1 35 31.1 0.8 3.6 85 18300 10900 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard.

slide 79:

77 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Three Core 3.6/6KV Um7.2KV Galvanized Flat Steel Wire+Steel Tape Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 25 6.05 2.5 0.1 16 12.5 0.8 2.2 40 2900 2400 35 7.10 2.5 0.1 16 13.7 0.8 2.3 42 3300 2700 50 8.25 2.5 0.1 16 14.7 0.8 2.4 45 3900 3000 70 9.90 2.5 0.1 16 16.3 0.8 2.5 49 4900 3600 95 11.7 2.5 0.1 16 18.1 0.8 2.6 53 6000 4200 120 13.1 2.5 0.1 16 19.5 0.8 2.7 56 7000 4700 150 14.3 2.5 0.1 25 20.7 0.8 2.8 59 8100 5200 185 16.3 2.5 0.1 25 22.7 0.8 2.9 64 9600 6100 240 18.7 2.6 0.1 25 25.3 0.8 3.1 70 11900 7200 300 20.9 2.8 0.1 25 27.9 0.8 3.3 76 14300 8600 400 23.7 3.0 0.1 35 31.1 0.8 3.6 84 17700 10300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 25 727/1200 927/1538 3.6/2.3 272 0.33 2.6 0.4 116 370 35 524/868 668/1113 5.0/3.2 301 0.36 2.6 0.5 108 350 50 387/641 494/822 6.8/4.4 332 0.40 2.6 0.5 102 330 70 268/443 343/568 9.8/6.3 383 0.46 2.6 0.6 97 310 95 193/320 248/410 13.3/8.5 432 0.52 2.6 0.6 92 290 120 153/253 196/325 17.2/11.0 474 0.57 2.6 0.7 89 280 150 124/206 159/265 21.2/13.5 511 0.61 4.3 0.7 87 280 185 99.1/164 128/211 26.6/17.0 562 0.67 4.3 0.8 86 270 240 75.4/125 98/161 34.9/22.3 602 0.72 4.3 0.9 83 260 300 60.1/100 80/130 43.8/28.0 622 0.75 4.3 1.0 82 260 400 47.0/77.8 64/102 57.3/36.6 648 0.78 5.8 1.1 80 250

slide 80:

Caledonian Medium V oltage Cables Three Core 6/10KV Um12KV N2XSEY NA2XSEY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm kg/km kg/km 25 6.05 3.4 0.1 16 14.3 1.6 41 2400 1900 35 7.10 3.4 0.1 16 15.3 1.6 43 2800 2200 50 8.25 3.4 0.1 16 16.5 1.7 46 3400 2500 70 9.90 3.4 0.1 16 18.1 1.7 50 4200 2900 95 11.7 3.4 0.1 16 19.9 1.8 54 5300 3400 120 13.1 3.4 0.1 16 21.3 1.8 57 6200 3900 150 14.3 3.4 0.1 25 22.5 1.9 60 7200 4400 185 16.3 3.4 0.1 25 24.5 1.9 64 8600 5100 240 18.7 3.4 0.1 25 26.9 2.0 70 10700 6100 300 20.9 3.4 0.1 25 29.1 2.1 75 12900 7100 400 23.7 3.4 0.1 35 31.9 2.2 81 15900 8500 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Three Core 6/10KV Um12KV Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 25 6.05 3.4 0.1 16 14.3 0.5 2.3 44 3200 2700 35 7.10 3.4 0.1 16 15.3 0.5 2.4 46 3700 3000 50 8.25 3.4 0.1 16 16.5 0.5 2.5 49 4300 3400 70 9.90 3.4 0.1 16 18.1 0.5 2.6 53 5200 3900 95 11.7 3.4 0.1 16 19.9 0.5 2.8 57 6400 4600 120 13.1 3.4 0.1 16 21.3 0.5 2.9 61 7400 5200 150 14.3 3.4 0.1 25 22.5 0.5 3.0 64 8500 5700 185 16.3 3.4 0.1 25 24.5 0.5 3.1 68 10000 6500 240 18.7 3.4 0.1 25 26.9 0.5 3.3 74 12300 7600 300 20.9 3.4 0.1 25 29.1 0.5 3.4 79 14600 8800 400 23.7 3.4 0.1 35 31.9 0.8 3.7 87 18700 11300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard.

slide 81:

79 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Three Core 6/10KV Um12KV Galvanized Flat Steel Wire+Steel Tape Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 25 6.05 3.4 0.1 16 14.3 0.8 2.3 44 3300 2800 35 7.10 3.4 0.1 16 15.3 0.8 2.4 46 3800 3100 50 8.25 3.4 0.1 16 16.5 0.8 2.5 49 4400 3500 70 9.90 3.4 0.1 16 18.1 0.8 2.6 53 5400 4100 95 11.7 3.4 0.1 16 19.9 0.8 2.8 57 6500 4700 120 13.1 3.4 0.1 16 21.3 0.8 2.9 61 7600 5300 150 14.3 3.4 0.1 25 22.5 0.8 3.0 64 8700 5900 185 16.3 3.4 0.1 25 24.5 0.8 3.1 68 10200 6800 240 18.7 3.4 0.1 25 26.9 0.8 3.3 74 12500 7900 300 20.9 3.4 0.1 25 29.1 0.8 3.4 79 14900 9100 400 23.7 3.4 0.1 35 31.9 0.8 3.7 86 18000 10600 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Wire Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 25 727/1200 927/1538 3.6/2.3 204 0.43 2.6 0.5 129 405 35 524/868 668/1113 5.0/3.2 237 0.47 2.6 0.6 115 370 50 387/641 494/822 6.8/4.4 260 0.52 2.6 0.6 109 350 70 268/443 343/568 9.8/6.3 298 0.60 2.6 0.7 103 330 95 193/320 248/410 13.3/8.5 334 0.67 2.6 0.7 99 320 120 153/253 196/325 17.2/11.0 365 0.73 2.6 0.8 96 310 150 124/206 159/265 21.2/13.5 392 0.78 4.3 0.8 93 300 185 99.1/164 128/211 26.6/17.0 430 0.86 4.3 0.9 90 290 240 75.4/125 98/161 34.9/22.3 476 0.95 4.3 0.9 87 280 300 60.1/100 80/130 43.8/28.0 524 1.05 4.3 1.0 85 270 400 47.0/77.8 64/102 57.3/36.6 580 1.16 5.8 1.1 81 260

slide 82:

Caledonian Medium V oltage Cables Three Core 8.7/15KV Um17.5KV N2XSEY NA2XSEY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm kg/km kg/km 25 6.05 4.5 0.1 16 16.5 1.7 46 3500 2400 35 7.10 4.5 0.1 16 17.5 1.7 48 3800 2600 50 8.25 4.5 0.1 16 18.7 1.7 51 4400 3000 70 9.90 4.5 0.1 16 20.3 1.8 55 5300 3400 95 11.7 4.5 0.1 16 22.1 1.8 59 6400 4000 120 13.1 4.5 0.1 16 23.5 1.9 62 7400 4500 150 14.3 4.5 0.1 25 24.7 1.9 65 8500 5000 185 16.3 4.5 0.1 25 26.7 2.0 69 10000 5800 240 18.7 4.5 0.1 25 29.1 2.1 75 12200 6800 300 20.9 4.5 0.1 25 31.3 2.1 80 14400 7900 400 23.7 4.5 0.1 35 34.1 2.2 87 17500 9300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Three Core 8.7/15KV Um17.5KV Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional Data Nom. Cross- Section Area Approx Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 25 6.05 4.5 0.1 16 16.5 0.5 2.5 49 3800 3300 35 7.10 4.5 0.1 16 17.5 0.5 2.6 51 4300 3600 50 8.25 4.5 0.1 16 18.7 0.5 2.7 54 4900 4000 70 9.90 4.5 0.1 16 20.3 0.5 2.8 58 5900 4600 95 11.7 4.5 0.1 16 22.1 0.5 2.9 62 7100 5300 120 13.1 4.5 0.1 16 23.5 0.5 3.0 66 8100 5900 150 14.3 4.5 0.1 25 24.7 0.5 3.1 69 9200 6400 185 16.3 4.5 0.1 25 26.7 0.5 3.3 74 10900 7400 240 18.7 4.5 0.1 25 29.1 0.5 3.4 79 13100 8500 300 20.9 4.5 0.1 25 31.3 0.5 3.6 86 16400 10600 400 23.7 4.5 0.1 35 34.1 0.8 3.9 93 19700 12300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard.

slide 83:

81 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Three Core 8.7/15KV Um17.5KV Galvanized Flat Steel Wire+Steel Tape Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 25 6.05 4.5 0.1 16 16.5 0.8 2.5 49 3400 3400 35 7.10 4.5 0.1 16 17.5 0.8 2.6 51 4400 3800 50 8.25 4.5 0.1 16 18.7 0.8 2.7 54 5100 4200 70 9.90 4.5 0.1 16 20.3 0.8 2.8 58 6000 4700 95 11.7 4.5 0.1 16 22.1 0.8 2.9 62 7300 5400 120 13.1 4.5 0.1 16 23.5 0.8 3.0 66 8300 6100 150 14.3 4.5 0.1 25 24.7 0.8 3.1 69 9400 6600 185 16.3 4.5 0.1 25 26.7 0.8 3.3 74 11100 7600 240 18.7 4.5 0.1 25 29.1 0.8 3.4 79 13400 8700 300 20.9 4.5 0.1 25 31.3 0.8 3.6 85 15800 10000 400 23.7 4.5 0.1 35 34.1 0.8 3.9 91 19000 11600 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩm µΩ/m kA pF/m mA/m kA kA µΩm nH/m 25 727/1200 927/1538 3.6/2.3 176 0.48 2.6 0.6 132 410 35 524/868 668/1113 5.0/3.2 193 0.53 2.6 0.6 123 390 50 387/641 494/822 6.8/4.4 211 0.58 2.6 0.7 116 370 70 268/443 343/568 9.8/6.3 240 0.65 2.6 0.7 110 350 95 193/320 248/410 13.3/8.5 267 0.73 2.6 0.8 105 330 120 153/253 196/325 17.2/11.0 291 0.79 2.6 0.8 102 320 150 124/206 159/265 21.2/13.5 312 0.85 4.3 0.9 98 310 185 99.1/164 128/211 26.6/17.0 340 0.93 4.3 0.9 95 300 240 75.4/125 98/161 34.9/22.3 375 1.02 4.3 1.0 91 290 300 60.1/100 80/130 43.8/28.0 411 1.12 4.3 1.1 89 280 400 47.0/77.8 64/102 57.3/36.6 454 1.24 5.8 1.2 84 270

slide 84:

Caledonian Medium V oltage Cables Three Core 12/20KV Um24KV N2XSEY NA2XSEY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm kg/km kg/km 35 7.10 5.5 0.1 16 19.7 1.8 53 3800 3100 50 8.25 5.5 0.1 16 20.9 1.8 56 4400 3500 70 9.90 5.5 0.1 16 22.5 1.9 60 5300 4000 95 11.7 5.5 0.1 16 24.3 1.9 64 6400 4600 120 13.1 5.5 0.1 16 25.7 2.0 67 7400 5200 150 14.3 5.5 0.1 25 26.9 2.0 70 8500 5700 185 16.3 5.5 0.1 25 28.9 2.1 75 10000 6500 240 18.7 5.5 0.1 25 31.3 2.1 80 12200 7500 300 20.9 5.5 0.1 25 33.5 2.2 85 14400 8700 400 23.7 5.5 0.1 35 36.3 2.3 91 17500 10200 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Three Core 12/20KV Um24KV Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 35 7.10 5.5 0.1 16 19.7 0.5 2.7 57 4900 4200 50 8.25 5.5 0.1 16 20.9 0.5 2.9 60 5600 4700 70 9.90 5.5 0.1 16 22.5 0.5 3.0 64 6600 5300 95 11.7 5.5 0.1 16 24.3 0.5 3.1 68 7800 6000 120 13.1 5.5 0.1 16 25.7 0.5 3.2 71 8900 6600 150 14.3 5.5 0.1 25 26.9 0.5 3.3 74 10100 7200 185 16.3 5.5 0.1 25 28.9 0.5 3.4 79 11700 8200 240 18.7 5.5 0.1 25 31.3 0.8 3.6 86 14900 10200 300 20.9 5.5 0.1 25 33.5 0.8 3.8 91 17400 11600 400 23.7 5.5 0.1 35 36.3 0.8 4.0 98 20800 13400 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard.

slide 85:

83 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Three Core 12/20KV Um24KV Galvanized Flat Steel Wire+Steel Tape Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 35 7.10 5.5 0.1 16 19.7 0.8 2.7 57 5000 4400 50 8.25 5.5 0.1 16 20.9 0.8 2.9 60 5700 4800 70 9.90 5.5 0.1 16 22.5 0.8 3.0 64 6800 5400 95 11.7 5.5 0.1 16 24.3 0.8 3.1 68 8000 6200 120 13.1 5.5 0.1 16 25.7 0.8 3.2 71 9100 6800 150 14.3 5.5 0.1 25 26.9 0.8 3.3 74 10300 7500 185 16.3 5.5 0.1 25 28.9 0.8 3.4 79 11900 8400 240 18.7 5.5 0.1 25 31.3 0.8 3.6 85 14300 9600 300 20.9 5.5 0.1 25 33.5 0.8 3.8 90 16700 10900 400 23.7 5.5 0.1 35 36.3 0.8 4.0 97 20100 12700 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capaci- tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 35 524/868 668/1113 5.0/3.2 168 0.67 2.6 0.7 129 410 50 387/641 494/822 6.8/4.4 183 0.73 2.6 0.8 122 390 70 268/443 343/568 9.8/6.3 207 0.83 2.6 0.8 115 370 95 193/320 248/410 13.3/8.5 229 0.92 2.6 0.9 110 350 120 153/253 196/325 17.2/11.0 249 1.00 2.6 0.9 106 340 150 124/206 159/265 21.2/13.5 266 1.06 4.3 1.0 103 330 185 99.1/164 128/211 26.6/17.0 289 1.16 4.3 1.0 100 320 240 75.4/125 98/161 34.9/22.3 318 1.27 4.3 1.1 95 300 300 60.1/100 80/130 43.8/28.0 348 1.39 4.3 1.2 93 300 400 47.0/77.8 64/102 57.3/36.6 388 1.53 5.8 1.3 87 280

slide 86:

Caledonian Medium V oltage Cables Three Core 18/30KV Um36KV N2XSEY NA2XSEY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm kg/km kg/km 50 8.25 8.0 0.1 16 25.9 2.0 68 5800 4900 70 9.90 8.0 0.1 16 27.5 2.0 71 6800 5500 95 11.7 8.0 0.1 16 29.3 2.1 75 8000 6100 120 13.1 8.0 0.1 16 30.7 2.1 79 9000 6700 150 14.3 8.0 0.1 25 31.9 2.2 81 10100 7300 185 16.3 8.0 0.1 25 33.9 2.2 86 11800 8300 240 18.7 8.0 0.1 25 36.3 2.3 91 14000 9400 300 20.9 8.0 0.1 25 38.5 2.4 97 16500 10700 400 23.7 8.0 0.1 35 41.3 2.5 103 19700 12300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Three Core 18/30KV Um36KV Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 50 8.25 8.0 0.1 16 25.9 0.5 3.2 72 7300 6400 70 9.90 8.0 0.1 16 27.5 0.5 3.3 75 8400 7100 95 11.7 8.0 0.1 16 29.3 0.5 3.5 80 9700 7900 120 13.1 8.0 0.1 16 30.7 0.8 3.6 84 11700 9400 150 14.3 8.0 0.1 25 31.9 0.8 3.7 87 12900 10100 185 16.3 8.0 0.1 25 33.9 0.8 3.9 92 14800 11300 240 18.7 8.0 0.1 25 36.3 0.8 4.0 98 17300 12600 300 20.9 8.0 0.1 25 38.5 0.8 4.2 103 20000 14100 400 23.7 8.0 0.1 35 41.3 0.8 4.4 110 23500 16000 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard.

slide 87:

85 www.caledonian-tech.com www.caledonian-tech.net Medium V oltage Cables to VDE 0276 Three Core 18/30KV Um36KV Galvanized Flat Steel Wire+Steel Tape Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional Data Nom. Cross- Section Area Approx. Conductor Diameter Nom. Insulation Thickness Copper Tape Thickness Copper Wire Screen Area Approx. Insulation Diameter Nom. Armour Thickness Nom. Sheath Thickness Approx. Overall Diameter Approx. Weight CU AL mm² mm mm mm mm² mm mm mm mm kg/km kg/km 50 8.25 8.0 0.1 16 25.9 0.8 3.2 72 7500 6600 70 9.90 8.0 0.1 16 27.5 0.8 3.3 76 8600 7300 95 11.7 8.0 0.1 16 29.3 0.8 3.5 80 10000 8100 120 13.1 8.0 0.1 16 30.7 0.8 3.6 83 11200 8900 150 14.3 8.0 0.1 25 31.9 0.8 3.7 86 12400 9500 185 16.3 8.0 0.1 25 33.9 0.8 3.9 91 14100 10600 240 18.7 8.0 0.1 25 36.3 0.8 4.0 97 16600 11900 300 20.9 8.0 0.1 25 38.5 0.8 4.2 102 19200 13400 400 23.7 8.0 0.1 35 41.3 0.8 4.4 109 22700 15300 Optional wire screen can be provided in combination of copper tapes. Nominal screen area as stated in the table can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 sec Capacitance Charging Current Short Circuit Rating of Copper Wire Screen Per Core 1 sec Short Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductance mm² µΩ/m µΩ/m kA pF/m mA/m kA kA µΩ/m nH/m 50 387/641 494/822 6.8/4.4 142 0.85 2.6 1.0 134 430 70 268/443 343/568 9.8/6.3 159 0.95 2.6 1.0 127 400 95 193/320 248/410 13.3/8.5 175 1.05 2.6 1.1 121 390 120 153/253 196/325 17.2/11.0 189 1.13 2.6 1.1 117 370 150 124/206 159/265 21.2/13.5 201 1.21 4.3 1.2 113 360 185 99.1/164 128/211 26.6/17.0 217 1.3 4.3 1.2 109 350 240 75.4/125 98/161 34.9/22.3 237 1.42 4.3 1.3 104 330 300 60.1/100 80/130 43.8/28.0 258 1.55 4.3 1.4 101 320 400 47.0/77.8 64/102 57.3/36.6 282 1.69 5.8 1.5 96 290

slide 88:

Caledonian Medium V oltage Cables Current Rating for Three Core 1.8/3KVUm7.2KV to 26/35KVUm42KV XLPE Insulation Unarmored Armored Nom. Cross- Section Area Buried direct in Ground Laid in Single Way Duct Laid in Air Buried direct in Ground Laid in Single Way Duct Laid in Air CU AL CU AL CU AL CU AL CU AL CU AL mm² A A A A A A 10 76 53 62 42 87 62 76 53 63 43 88 63 16 101 78 87 67 109 84 101 78 88 68 110 85 25 129 100 112 87 142 110 129 100 112 87 143 111 35 153 119 133 103 170 132 154 119 134 104 172 133 50 181 140 158 122 204 158 181 140 158 123 205 159 70 221 171 193 150 253 196 220 171 194 150 253 196 95 262 203 231 179 304 236 263 204 232 180 307 238 120 298 232 264 205 351 273 298 232 264 206 352 274 150 334 260 297 231 398 309 332 259 296 231 397 309 185 377 294 336 262 455 355 374 293 335 262 453 354 240 434 340 390 305 531 415 431 338 387 304 529 415 300 489 384 441 346 606 475 482 380 435 343 599 472 400 553 438 501 398 696 552 541 432 492 393 683 545 500 613 498 541 451 786 652 601 492 532 446 773 645 630 663 568 591 501 896 762 651 562 582 496 883 755

slide 89:

V I II III IV V Technical Information Caledonian Medium Voltage Cables

slide 90:

Caledonian Medium V oltage Cables Technical Information ▓ Current Ratings The current ratings given on the previous pages are based on the standard conditions of installation detailed bellows: Maximum conductor temperature: 90°C Maximum ambient temperature: In air 30°C In ground 20°C Ground thermal resistivity: 1.5K•m/W Laying depth: 0.8m Spacing between cable laid: In fat formation 2 times of cable overall diameter In trefoil With cable touching Where the site conditions differ from the standard conditions mentioned it will be necessary to multiply the tabulated ratings by the actors given in the following tables. These factors are for variation in ambient ground temperature soil thermal resistivity and depth of laying. Where more than one circuit is installed in close proximity then will be necessary to derate further in accordance with the group rating factors given. ▓ Rating Factors Cables laid direct in ground: Variation in ground temperature Ground Temperature 15 20 25 30 35 40 45 Cabe Type Rating Factor All Cables 1.00 0.97 0.93 0.89 0.86 0.82 0.76 Rating factor for depth of laying To center of cable or trefoil group of cables Depth of laying 1.9/3.3KV 1.8/3KV to 19/33KV 18/30KV Cables m Up to 300 mm² Above 300 mm² 0.50 - - 0.60 - - 0.80 1.00 1.00 1.00 0.98 0.97 1.25 0.96 0.95 1.50 0.95 0.94 1.75 0.94 0.92 2.00 0.92 0.90 2.50 0.91 0.89 3.00 or more 0.90 0.88

slide 91:

89 www.caledonian-tech.com www.caledonian-tech.net Technical Information Rating factor for variation in thermal resistivity of soil depth Nom.Cross- Section Area Soil thermal resistivity K.m/W 0.8 0.9 1.0 1.5 2.0 2.5 3.0 Single 50 1.15 1.11 1.07 0.91 0.81 0.73 0.68 70 1.16 1.12 1.07 0.91 0.81 0.73 0.68 95 1.16 1.12 1.07 0.91 0.81 0.73 0.68 120 1.16 1.12 1.07 0.91 0.81 0.73 0.68 150 1.17 1.12 1.07 0.91 0.81 0.73 0.68 185 1.17 1.12 1.07 0.91 0.81 0.73 0.68 240 1.17 1.12 1.07 0.91 0.80 0.73 0.68 300 1.18 1.12 1.07 0.91 0.80 0.73 0.68 400 1.18 1.12 1.07 0.91 0.80 0.73 0.67 500 1.18 1.12 1.07 0.91 0.80 0.73 0.67 630 1.18 1.12 1.07 0.91 0.80 0.73 0.67 800 1.18 1.12 1.07 0.91 0.80 0.72 0.67 1000 1.18 1.12 1.07 0.91 0.80 0.72 0.67 Multicore 16 1.12 1.08 1.05 0.93 0.84 0.77 0.72 25 1.13 1.09 1.05 0.93 0.83 0.77 0.71 35 1.13 1.09 1.06 0.92 0.83 0.76 0.71 50 1.13 1.09 1.06 0.92 0.83 0.76 0.71 70 1.14 1.09 1.06 0.92 0.83 0.75 0.70 95 1.14 1.09 1.06 0.92 0.83 0.75 0.70 120 1.14 1.10 1.06 0.92 0.82 0.75 0.69 150 1.14 1.10 1.06 0.92 0.82 0.75 0.69 185 1.14 1.10 1.06 0.92 0.82 0.74 0.69 240 1.15 1.10 1.07 0.92 0.82 0.74 0.69 300 1.15 1.10 1.07 0.92 0.82 0.74 0.69 400 1.15 1.10 1.07 0.92 0.82 0.74 0.69 Group rating factor for circuits of three single core cables. In trefoil and laid flat touching horizontal formation average values No. of circuits Spacing of circuits Touching Trefoil Laid Flat 0.15m 0.3m 0.45m 0.6m 1.9/3.3KV1.8/3KV to 12.7/22KV 12/20KV Cables 2 0.78 0.80 0.81 0.85 0.88 0.90 3 0.66 0.68 0.71 0.76 0.80 0.83 4 0.59 0.62 0.65 0.72 0.76 0.80 5 0.55 0.58 0.61 0.68 0.73 0.77 6 0.52 0.55 0.58 0.66 0.72 0.76 19/33KV18/30KV Cables 2 0.79 0.81 0.81 0.85 0.88 0.90 3 0.67 0.70 0.71 0.76 0.80 0.83 4 0.62 0.65 0.65 0.72 0.76 0.80 5 0.57 0.60 0.60 0.68 0.73 0.77 6 0.54 0.57 0.57 0.66 0.70 0.76 This confguration at 0.15m spacing may not be practical for the larger size cables.

slide 92:

Caledonian Medium V oltage Cables Group rating factor for multicore cables in horizontal formation average values No. of cables in group Spacing Touching 0.15m 0.3m 0.45m 0.6m 1.9/3.3KV1.8/3KV to 12.7/22KV 12/20KV Cables 2 0.80 0.85 0.89 0.90 0.92 3 0.68 0.75 0.80 0.84 0.86 4 0.62 0.70 0.77 0.80 0.84 5 0.57 0.66 0.73 0.78 0.81 6 0.55 0.63 0.71 0.76 0.80 19/33KV18/30KV Cables 2 0.80 0.83 0.87 0.89 0.91 3 0.70 0.73 0.78 0.82 0.85 4 0.64 0.68 0.74 0.78 0.82 5 0.59 0.63 0.70 0.75 0.79 6 0.56 0.60 0.68 0.74 0.78 Cables laid direct in single way ducts: The term “ducts” applies to single earthenware fbre or plastic pipes. Variation in ground temperature Ground Temperature 15 20 25 30 35 40 45 Cabe Type Rating Factor All Cables 1.00 0.97 0.93 0.89 0.86 0.82 0.76 Rating factor for depth of laying To center of cable or trefoil group of cables Depth of Laying 600/1000V cables 1900/3300V to 19000/33000V cables m Single Core Multicore Single Core Multicore 0.50 1.00 1.00 - - 0.60 0.98 0.99 - - 0.80 0.95 0.97 1.00 1.00 1.00 0.93 0.96 0.98 0.99 1.25 0.90 0.95 0.95 0.97 1.50 0.89 0.94 0.93 0.96 1.75 0.88 0.94 0.92 0.95 2.00 0.87 0.93 0.90 0.95 2.50 0.86 0.92 0.89 0.93 3.00 or more 0.85 0.91 0.88 0.92

slide 93:

91 www.caledonian-tech.com www.caledonian-tech.net Technical Information Rating factor for variation in thermal resistivity of soil depth Nom.Cross- Section Area mm² Soil thermal resistivity K.m/W 0.8 0.9 1.0 1.5 2.0 2.5 3.0 Single Core 50 1.08 1.06 1.04 0.94 0.87 0.82 0.77 70 1.09 1.06 1.04 0.94 0.87 0.81 0.76 95 1.09 1.06 1.04 0.94 0.87 0.81 0.76 120 1.10 1.07 1.04 0.94 0.86 0.80 0.75 150 1.10 1.07 1.04 0.94 0.86 0.80 0.75 185 1.10 1.07 1.04 0.93 0.86 0.79 0.75 240 1.11 1.07 1.05 0.93 0.86 0.79 0.74 300 1.11 1.08 1.05 0.93 0.85 0.79 0.74 400 1.11 1.08 1.05 0.93 0.85 0.78 0.73 500 1.11 1.08 1.05 0.93 0.85 0.78 0.73 630 1.12 1.08 1.05 0.93 0.84 0.78 0.72 800 1.12 1.09 1.05 0.93 0.84 0.77 0.72 1000 1.13 1.09 1.05 0.93 0.84 0.77 0.71 Multicore 16 1.04 1.03 1.02 0.97 0.92 0.88 0.85 25 1.05 1.03 1.02 0.96 0.92 0.88 0.84 35 1.05 1.03 1.02 0.96 0.92 0.87 0.83 50 1.05 1.03 1.02 0.96 0.91 0.87 0.83 70 1.05 1.04 1.02 0.96 0.91 0.86 0.82 95 1.06 1.04 1.02 0.96 0.91 0.86 0.82 120 1.06 1.04 1.03 0.95 0.90 0.85 0.81 150 1.06 1.04 1.03 0.95 0.90 0.85 0.80 185 1.07 1.05 1.03 0.95 0.89 0.84 0.80 240 1.07 1.05 1.03 0.95 0.89 0.84 0.79 300 1.07 1.05 1.03 0.95 0.88 0.83 0.78 400 1.07 1.05 1.03 0.95 0.88 0.83 0.78 Group rating factor for circuits of three single core cables In trefoil single way ducts horizontal formation average values No. of circuits Spacing Touching 0.45m 0.60m 1.9/3.3KV1.8/3KV to 12.7/22KV12/20KV Cables 2 0.85 0.88 0.90 3 0.75 0.80 0.83 4 0.70 0.76 0.80 5 0.67 0.73 0.77 6 0.64 0.71 0.76 19/33KV18/30KV Cables 2 0.85 0.88 0.90 3 0.76 0.80 0.83 4 0.71 0.76 0.80 5 0.67 0.73 0.77 6 0.65 0.71 0.76

slide 94:

Caledonian Medium V oltage Cables Group rating factor for multicore cables in single way ducts horizontal formation average values No. of ducts in group Spacing Touching 0.30m 0.45m 0.60m 1.9/3.3KV1.8/3KV to 12.7/22KV12/20KV Cables 2 0.88 0.91 0.93 0.94 3 0.80 0.84 0.87 0.89 4 0.75 0.81 0.84 0.87 5 0.71 0.77 0.82 0.85 6 0.69 0.75 0.80 0.84 19/33KV18/30KV Cables 2 0.87 0.89 0.92 0.93 3 0.78 0.82 0.85 0.87 4 0.73 0.78 0.82 0.85 5 0.69 0.75 0.79 0.83 6 0.67 0.73 0.78 0.82 Cables laid direct in free air: Variation in air temperature Ground Temperature 25 30 35 40 45 50 55 Cabe Type Rating Factor Cable Type up to 3.3KV 1.02 1.00 0.96 0.91 0.87 0.82 0.76 6.6KV or Above 1.00 0.95 0.91 0.86 0.80 0.75 0.69 Effect of grouping cables No reduction in rating is necessary where there is free circulation of air around the circuits providing that: 1 The horizontal clearance between circuits is not less than twice the overall diameter of an individual cable. 2 The vertical clearance between circuits is not less than four times the diameter of an individual cable. 3 If the number of circuits exceeds three they are installed in a horizontal plane.

slide 95:

93 www.caledonian-tech.com www.caledonian-tech.net Technical Information ▓ Short Circuit Ratings Short circuit rating –Copper conductor current in kiloamps 100 90 1000 sq mm 800 sq mm 630 sq mm 500 sq mm 400 sq mm 300 sq mm 240 sq mm 185 sq mm 150 sq mm 120 sq mm 95 sq mm 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 2.0 3.0 70 sq mm 35 sq mm 50 sq mm 25 sq mm 16 sq mm Currrnt In KiloAMPS Duration of Short Circuit In Seconds Basis: 1. Cable fully located at start of short circuit. Conductor temperature: 90°C 2. Conductor temperature at end of short circuit: 250°C

slide 96:

Caledonian Medium V oltage Cables Short circuit rating –Aluminium conductor current in kiloamps 1000 sq mm 800 sq mm 630 sq mm 500 sq mm 400 sq mm 300 sq mm 240 sq mm 150 sq mm 120 sq mm 70 sq mm 50 sq mm 35 sq mm 25 sq mm 16 sq mm 95 sq mm 185 sq mm 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 2.0 3.0 Currrnt In KiloAMPS Duration of Short Circuit In Seconds Basis: 1. Cable fully located at start of short circuit. Conductor temperature: 90°C 2. Conductor temperature at end of short circuit: 250°C

slide 97:

95 www.caledonian-tech.com www.caledonian-tech.net Technical Information Armour fault current Nom. Cross- Section Area mm² Aluminium Wire Armoured Cables Steel Wire Armoured Cables 3.8/6.6 3.6/6 KV 6.35/11 6/12 KV 8.7/15 KV 12.7/22 12/20 KV 18/30 19/33 KV 3.8/6.6 3.6/6 KV 6.35/11 6/12 KV 8.7/15 KV 12.7/22 12/20 KV 18/30 19/33 KV 25 7370 10160 11510 35 7800 10830 11960 13090 50 6150 6660 7340 7860 12010 10380 11290 12640 13770 21500 70 6660 7170 7860 10680 12810 11290 12190 13540 14670 22580 95 7170 7690 10410 11210 13350 12190 13320 14450 19710 24010 120 7520 8030 10940 11750 13880 13090 14220 15350 20790 25090 150 8030 10680 11480 12280 18350 13770 14900 16030 21860 25810 185 10680 11480 12280 12810 19190 14900 15800 21860 23300 27240 240 11750 12280 13060 13880 20020 16480 21860 23660 25090 29030 300 12550 13080 13880 18770 21690 22580 23660 25090 26520 30830 400 13880 14150 19190 20020 22940 25090 25810 27240 28670 500 19190 19610 20440 21690 24610 630 21270 21270 22530 23360 26280 800 23360 23360 24610 25450 28790 1000 25450 25450 26700 27530 30870 Wire screen Nom.Cross-Section Area Maximum DC resistance at 20°C Short Circuit Rating mm² Ohm/km A 16 1.19 2040 25 0.759 3200 35 0.542 4480 Copper wire applied helically or tape screen applied individually to each screened core or collectively over laid up provide an earth fault current path.

slide 98:

Product Range of Medium Voltage Cable Standard Voltage Sizesq mm No. of Cores BS 6622/BS 7835 3.8/6.6KV 25-630 Single BS 6622/BS 7835 6.35/11KV 25-630 Single BS 6622/BS 7835 8.7/15KV 25-630 Single BS 6622/BS 7835 12.7/22KV 35-630 Single BS 6622/BS 7835 19/33KV 50-630 Single BS 6622/BS 7835 3.8/6.6KV 25-400 Three BS 6622/BS 7835 6.35/11KV 25-400 Three BS 6622/BS 7835 8.7/15KV 25-400 Three BS 6622/BS 7835 12.7/22KV 35-400 Three BS 6622/BS 7835 19/33KV 35-400 Three IEC 60502 1.8/3KV 10-1000 Single IEC 60502 3.6/6KV 10-1000 Single IEC 60502 6/10KV 16-1000 Single IEC 60502 8.7/15KV 25-1000 Single IEC 60502 12/20KV 25-1000 Single IEC 60502 18/30KV 50-1000 Single IEC 60502 21/35KV 50-400 Single IEC 60502 26/35KV 50-400 Single IEC 60502 1.8/3KV 10-630 Three IEC 60502 3.6/6KV 10-630 Three IEC 60502 6/10KV 16-630 Three IEC 60502 8.7/15KV 25-500 Three IEC 60502 12/20KV 35-500 Three IEC 60502 18/30KV 50-500 Three IEC 60502 21/35KV 50-400 Three IEC 60502 26/35KV 50-400 Three VDE 0276 1.8/3KV 25-800 Single VDE 0276 3.6/6KV 25-800 Single VDE 0276 6/10KV 25-800 Single VDE 0276 8.7/15KV 25-800 Single VDE 0276 12/20KV 25-800 Single VDE 0276 18/30KV 25-800 Single VDE 0276 1.8/3KV 25-400 Three VDE 0276 3.6/6KV 25-400 Three VDE 0276 6/10KV 25-400 Three VDE 0276 8.7/15KV 25-400 Three VDE 0276 12/20KV 35-400 Three VDE 0276 18/30KV 50-400 Three

slide 99:

I II III IV V I Cable Properties Construction 03 Cable Machinery Equipments 05 Product Testing 06 Cable Options Ordering Information 09 II Medium Voltage Cables to BS 6622/BS 7835 Single Core Cables to BS 6622/BS 7835 Three Core Cables to BS 6622/BS 7835 12 30 III Medium Voltage Cables to IEC 60502 Single Core Cables to IEC 60502 Three Core Cables to IEC 60502 31 59 IV Medium Voltage Cables to VDE 0276 Single Core Cables to VDE 0276 Three Core Cables to VDE 0276 60 86 V Technical Information 87 95 Table of Contents

slide 100:

Address: Marchants Industrial Centre MiII Lane Laughton Lewes East Sussex BN8 6AJ UK Tel: 44-207-4195087 Fax: 44-207-8319489 E-mail: salescaledonian-tech.net www.caledonian-tech.net Medium Voltage Cables