logging in or signing up cisco authorvikas Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 309 Category: Education License: All Rights Reserved Like it (1) Dislike it (0) Added: December 03, 2010 This Presentation is Public Favorites: 0 Presentation Description datasheets Comments Posting comment... Premium member Presentation Transcript Ordering UCS M2 C-Series Rack ServerChannel Bundles April 2010 : Ordering UCS M2 C-Series Rack ServerChannel Bundles April 2010 Benefits of M2 C-Series Channel Configurations : Benefits of M2 C-Series Channel Configurations 7 Channel configurations available through Distribution Partners Configurations positioned for a range of environments 1 bundle option for UCS C200 M2 2 bundles option for UCS C210 M2 4 bundles option for UCS C250 M2 For the following reasons, we highly recommend ordering via these configurations: Fast sales cycle, short lead time (shipped from distribution stock) Automatic high-discount special pricing, removing special-pricing approval process. Parts included in configurations cannot be removed. Additional components may be ordered as Spares(e.g, RAM, HDDs, etc). Shorter Lead times. The simplified configuration process allows the channel bundles to be pre-made. How to use this guide : How to use this guide Choose the appropriate server on the next page. For details about the offerings each server provides, go to www.cisco.com/ucs and browse the “rack mount servers” tab. Choose the appropriate channel configurations (slides 5 - 8). Note: The C210 M2 and C250 M2 configurations come in both standard and high-performance versions. The C250 M2 also has standard and high-memory versions. Advance to the configuration slide to add any additional options (as spares). Note Server will function without additional configuration. Please note each bundle has one configurable item – the power cord – please choose country specific cord. This guide shows what parts are compatible with each server, and how many you can add onto a configuration. Add services and software Start by Choosing Your Base Server : Start by Choosing Your Base Server UCS C210 M2 General-Purpose Rack Server PID: R210-212160W UCS C250 M2 Extended Memory Rack Server PID: R250-248080W UCS C200 M2 High-Density Rack-Mount Server PID: R200-112040W Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C200 M2 Server Chassis Page 9 Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C210 M2 Server Chassis Page 13 Page 17 Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C250 M2 Server Chassis – Standard Configs(Intel X5650) Page 25 Page 21 Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C250 M2 Server Chassis – High-Performance (Intel X5670) Page 33 Page 29 R200-STAND-CNFGW Additional Configuration : R200-STAND-CNFGW Additional Configuration 9 Configuring R200-STAND-CNFG (Steps 1 and 2) : Configuring R200-STAND-CNFG (Steps 1 and 2) Step 1: Dual CPU’s included with configuration: 2x 2.40GHz Xeon E5620 80W CPU/12MB cache/DDR3 1066MHz Memory Notes: There are 6 DIMM slots per CPU, for a total of 12 slots. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs can NOT be mixed. Configuring R200-STAND-CNFG(Steps 3, 4) : Configuring R200-STAND-CNFG(Steps 3, 4) Configuring R200-STAND-CNFG (Steps 5-9) : Configuring R200-STAND-CNFG (Steps 5-9) Step 6: Select Power Cords (select 2): : Default is Two 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 7: Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Step 8: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit and used for cable management Cable Management Arm: (PID: R250-CBLARM) Note: Image shows PCIe card already inserted R210-STAND-CNFGW Additional Configuration : R210-STAND-CNFGW Additional Configuration 13 Configuring R210-STAND-CNFGW (Steps 1 and 2) : Configuring R210-STAND-CNFGW (Steps 1 and 2) Step 1: Dual CPU’s included with configuration: 2x 2.40GHz Xeon E5620 80W CPU/12MB cache/DDR3 1066MHz (PID: A01-X0111) Memory Notes: There are 6 DIMM slots per CPU, for a total of 12 slots. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs can NOT be mixed. Slide 15: Configuring R210-STAND-CNFGW (Step 3) Included: RAID Controller LSI 1064 Controller-Based Mezzanine Card (PID: R2X0-ML002) Used on the 1 Mezz Slot on a C210 M1 Supports up to 4 SAS or SATA hard drives If customer plans more that 4 drives order R210-SASXPDN-CNFGW bundle Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD For more than 4 Drives, an LSI MegaRaid controller is required; which is included on the SAS expansion bundle (R210-SASXPND-CNFGW] Configuring R210-STAND-CNFGW (Steps 5 - 9) : Configuring R210-STAND-CNFGW (Steps 5 - 9) Step 7: Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Step 8: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit and used for cable management Cable Management Arm: (PID: R250-CBLARM) Step 6: Select Power Cords (select 2): Default is: Two 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) R210-SASXPND-CNFGW Additional Configuration : R210-SASXPND-CNFGW Additional Configuration 17 Configuring R210-SASXPND-CNFGW (Steps 1 and 2) : Configuring R210-SASXPND-CNFGW (Steps 1 and 2) Step 1: Dual CPU’s included with configuration: 2.66GHz Xeon E5640 80W CPU/12MB cache/DDR3 1066MHz (PID: A01-X0109) Memory Notes: There are 6 DIMM slots per CPU, for a total of 12 slots. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs can NOT be mixed. Slide 19: Configuring R210-SASXPND-CNFGW (Step 3) Included: RAID Controller LSI 6G MegaRAID 9261-8i card (PID: R2XX-PL003) Takes up 1 of five available PCIe slots Supports up to 16 SAS or SATA drives Includes 512MB of Write Cache Battery Back-Up Option Available Battery Back-up Option (PID: R2XX-LBBU2) Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD Configuring R210-SASXPND-CNFGW (Steps 5 - 9) : Configuring R210-SASXPND-CNFGW (Steps 5 - 9) Special Notes: on PCIe cards: This bundle can host 4 additional PCIe option cards (MegaRAID card occupies 5th slot) All option cards above are “Low Profile/Half-Length Cards. All cards above will fit in either slot above. Step 7: Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Step 8: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit and used for cable management Cable Management Arm: (PID: R250-CBLARM) Step 6: Select Power Cords (select 2):Default is Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) R250-STND-CNFGW Additional Configuration : R250-STND-CNFGW Additional Configuration 21 Configuring R250-STND-CNFGW (Steps 1 and 2) : Configuring R250-STND-CNFGW (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.66GHz Xeon X5650 95W CPU/12MB cache/DDR3 1333MHz (PID: A01-X0105) Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250 M2 and B250 M2. All DIMMs supported on the C250 M2 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 23: * For more than 4 Drives, LSI MegaRaid controller is required, which is included in the C250 performance configurations Configuring R250-STND-CNFGW (Step 3) Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD Slide 24: Step 5 Select Power Cords (select 2):Default is: Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-STND-CNFGW (Step 4-6) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) R250-STND-CNFGW-2 (High-Memory)Additional Configuration : R250-STND-CNFGW-2 (High-Memory)Additional Configuration 25 Configuring R250-STND-CNFGW-2 (Steps 1 and 2) : Configuring R250-STND-CNFGW-2 (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.66GHz Xeon X5650 95W CPU/12MB cache/DDR3 1333MHz (PID: A01-X0105) Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250M2 and B250 M2. All DIMMs supported on the C250 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 27: * For more than 4 Drives, LSI MegaRaid controller is required, which is included in the C250 performance bundles Configuring LA R250-STND-CNFGW-2 (Step 3) Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD Slide 28: Step 5: Select Power Cords (select 2):Default isTwo 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-STND-CNFGW-2 (Step 4-6) Dual Redundant Power Supplies Included with Configuration 750W power supply unit for UCS C250 Rack Server (PID: R250-PSU2-750W) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) R250-PERF-CNFGW Additional Configuration : R250-PERF-CNFGW Additional Configuration 29 Configuring R250-PERF-CNFGW (Steps 1 and 2) : Configuring R250-PERF-CNFGW (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.93GHz Xeon X5670 95W CPU/8MB cache/DDR3 1333MHz Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250 and B250. All DIMMs supported on the C250 M2 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 31: Note on RAID – if customer wishes to configure RAID on their server, the hard drives mush be the same speed, size and capacity. Minimum # HDD needed for RAID: RAID 0 = 1 HDD; RAID 1 = 2 HDD; RAID 5 = 3+ HDD; RAID 6 and RAID 10 = 4+ HDD Configuring R250-PERF-CNFGW (Step 3) Slide 32: Special Notes: on PCIe cards: The C250 M2 can host 4 PCIe option cards (RAID card in 5th slot) All option cards above are “Low Profile/Half-Length Cards. All cards above will fit in either PCIe slots (Low profile or Standard high) Step 5: Select Power Cords (select 2):Default is: Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 M2 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-PERF-CNFGW (Step 4-6) Dual Redundant Power Supplies Included with Configuration 750W power supply unit for UCS C250 Rack Server (PID: R250-PSU2-750W) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) R250-PERF-CNFGW-2 High MemoryAdditional Configuration : R250-PERF-CNFGW-2 High MemoryAdditional Configuration 33 Configuring R250-PERF-CNFGW-2 (Steps 1 and 2) : Configuring R250-PERF-CNFGW-2 (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.93GHz Xeon X5670 95W CPU/8MB cache/DDR3 1333MHz (PID: A01-X0102) Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250 M2 and B250 M2. All DIMMs supported on the C250 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 35: Configuring LA R250-CNFGW-2 (Step 3) Note on RAID – if customer wishes to configure RAID on their server, the hard drives mush be the same speed, size and capacity. Minimum # HDD needed for RAID: RAID 0 = 1 HDD; RAID 1 = 2 HDD; RAID 5 = 3+ HDD; RAID 6 and RAID 10 = 4+ HDD Slide 36: Special Notes: on PCIe cards: The C250 M2 can host 4 PCIe option cards (RAID card in 5th slot) All option cards above are “Low Profile/Half-Length Cards. All cards above will fit in either PCIe slots (Low profile or Standard high) Step 5: Select Power Cords (select 2):Default is: Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-PERF-CNFGW-2 (Step 4-6) Dual Redundant Power Supplies Included with Configuration 750W power supply unit for UCS C250 Rack Server (PID: R250-PSU2-750W) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Services and Software : Services and Software 37 Slide 38: MS Windows Server 2003, 2008, Linux, RedHat and Novell SUSe Linux, VMware and BMC Bladelogic (Operations Mgr and Configuration Mgr) – SW license and Service bought at time of UCS Sale. Unified Computing Technical ServicesTake a Systems approach to attaching HW and SW Service – UCS-C Useful Links to UCS Services Sales Acceleration Center http://wwwin.cisco.com/WWSales/wwops/sac/ Services for UCS - internal http://wwwin.cisco.com/CustAdv/services/advtech/datacenter/technologies/unifiedcomputing/ Services for UCS – external http://www.cisco.com/en/US/products/ps10312/serv_group_home.html You do not have the permission to view this presentation. In order to view it, please contact the author of the presentation.
cisco authorvikas Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 309 Category: Education License: All Rights Reserved Like it (1) Dislike it (0) Added: December 03, 2010 This Presentation is Public Favorites: 0 Presentation Description datasheets Comments Posting comment... Premium member Presentation Transcript Ordering UCS M2 C-Series Rack ServerChannel Bundles April 2010 : Ordering UCS M2 C-Series Rack ServerChannel Bundles April 2010 Benefits of M2 C-Series Channel Configurations : Benefits of M2 C-Series Channel Configurations 7 Channel configurations available through Distribution Partners Configurations positioned for a range of environments 1 bundle option for UCS C200 M2 2 bundles option for UCS C210 M2 4 bundles option for UCS C250 M2 For the following reasons, we highly recommend ordering via these configurations: Fast sales cycle, short lead time (shipped from distribution stock) Automatic high-discount special pricing, removing special-pricing approval process. Parts included in configurations cannot be removed. Additional components may be ordered as Spares(e.g, RAM, HDDs, etc). Shorter Lead times. The simplified configuration process allows the channel bundles to be pre-made. How to use this guide : How to use this guide Choose the appropriate server on the next page. For details about the offerings each server provides, go to www.cisco.com/ucs and browse the “rack mount servers” tab. Choose the appropriate channel configurations (slides 5 - 8). Note: The C210 M2 and C250 M2 configurations come in both standard and high-performance versions. The C250 M2 also has standard and high-memory versions. Advance to the configuration slide to add any additional options (as spares). Note Server will function without additional configuration. Please note each bundle has one configurable item – the power cord – please choose country specific cord. This guide shows what parts are compatible with each server, and how many you can add onto a configuration. Add services and software Start by Choosing Your Base Server : Start by Choosing Your Base Server UCS C210 M2 General-Purpose Rack Server PID: R210-212160W UCS C250 M2 Extended Memory Rack Server PID: R250-248080W UCS C200 M2 High-Density Rack-Mount Server PID: R200-112040W Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C200 M2 Server Chassis Page 9 Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C210 M2 Server Chassis Page 13 Page 17 Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C250 M2 Server Chassis – Standard Configs(Intel X5650) Page 25 Page 21 Choosing Your Channel Configuration : Choosing Your Channel Configuration UCS C250 M2 Server Chassis – High-Performance (Intel X5670) Page 33 Page 29 R200-STAND-CNFGW Additional Configuration : R200-STAND-CNFGW Additional Configuration 9 Configuring R200-STAND-CNFG (Steps 1 and 2) : Configuring R200-STAND-CNFG (Steps 1 and 2) Step 1: Dual CPU’s included with configuration: 2x 2.40GHz Xeon E5620 80W CPU/12MB cache/DDR3 1066MHz Memory Notes: There are 6 DIMM slots per CPU, for a total of 12 slots. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs can NOT be mixed. Configuring R200-STAND-CNFG(Steps 3, 4) : Configuring R200-STAND-CNFG(Steps 3, 4) Configuring R200-STAND-CNFG (Steps 5-9) : Configuring R200-STAND-CNFG (Steps 5-9) Step 6: Select Power Cords (select 2): : Default is Two 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 7: Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Step 8: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit and used for cable management Cable Management Arm: (PID: R250-CBLARM) Note: Image shows PCIe card already inserted R210-STAND-CNFGW Additional Configuration : R210-STAND-CNFGW Additional Configuration 13 Configuring R210-STAND-CNFGW (Steps 1 and 2) : Configuring R210-STAND-CNFGW (Steps 1 and 2) Step 1: Dual CPU’s included with configuration: 2x 2.40GHz Xeon E5620 80W CPU/12MB cache/DDR3 1066MHz (PID: A01-X0111) Memory Notes: There are 6 DIMM slots per CPU, for a total of 12 slots. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs can NOT be mixed. Slide 15: Configuring R210-STAND-CNFGW (Step 3) Included: RAID Controller LSI 1064 Controller-Based Mezzanine Card (PID: R2X0-ML002) Used on the 1 Mezz Slot on a C210 M1 Supports up to 4 SAS or SATA hard drives If customer plans more that 4 drives order R210-SASXPDN-CNFGW bundle Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD For more than 4 Drives, an LSI MegaRaid controller is required; which is included on the SAS expansion bundle (R210-SASXPND-CNFGW] Configuring R210-STAND-CNFGW (Steps 5 - 9) : Configuring R210-STAND-CNFGW (Steps 5 - 9) Step 7: Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Step 8: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit and used for cable management Cable Management Arm: (PID: R250-CBLARM) Step 6: Select Power Cords (select 2): Default is: Two 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) R210-SASXPND-CNFGW Additional Configuration : R210-SASXPND-CNFGW Additional Configuration 17 Configuring R210-SASXPND-CNFGW (Steps 1 and 2) : Configuring R210-SASXPND-CNFGW (Steps 1 and 2) Step 1: Dual CPU’s included with configuration: 2.66GHz Xeon E5640 80W CPU/12MB cache/DDR3 1066MHz (PID: A01-X0109) Memory Notes: There are 6 DIMM slots per CPU, for a total of 12 slots. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs can NOT be mixed. Slide 19: Configuring R210-SASXPND-CNFGW (Step 3) Included: RAID Controller LSI 6G MegaRAID 9261-8i card (PID: R2XX-PL003) Takes up 1 of five available PCIe slots Supports up to 16 SAS or SATA drives Includes 512MB of Write Cache Battery Back-Up Option Available Battery Back-up Option (PID: R2XX-LBBU2) Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD Configuring R210-SASXPND-CNFGW (Steps 5 - 9) : Configuring R210-SASXPND-CNFGW (Steps 5 - 9) Special Notes: on PCIe cards: This bundle can host 4 additional PCIe option cards (MegaRAID card occupies 5th slot) All option cards above are “Low Profile/Half-Length Cards. All cards above will fit in either slot above. Step 7: Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Step 8: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit and used for cable management Cable Management Arm: (PID: R250-CBLARM) Step 6: Select Power Cords (select 2):Default is Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) R250-STND-CNFGW Additional Configuration : R250-STND-CNFGW Additional Configuration 21 Configuring R250-STND-CNFGW (Steps 1 and 2) : Configuring R250-STND-CNFGW (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.66GHz Xeon X5650 95W CPU/12MB cache/DDR3 1333MHz (PID: A01-X0105) Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250 M2 and B250 M2. All DIMMs supported on the C250 M2 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 23: * For more than 4 Drives, LSI MegaRaid controller is required, which is included in the C250 performance configurations Configuring R250-STND-CNFGW (Step 3) Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD Slide 24: Step 5 Select Power Cords (select 2):Default is: Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-STND-CNFGW (Step 4-6) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) R250-STND-CNFGW-2 (High-Memory)Additional Configuration : R250-STND-CNFGW-2 (High-Memory)Additional Configuration 25 Configuring R250-STND-CNFGW-2 (Steps 1 and 2) : Configuring R250-STND-CNFGW-2 (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.66GHz Xeon X5650 95W CPU/12MB cache/DDR3 1333MHz (PID: A01-X0105) Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250M2 and B250 M2. All DIMMs supported on the C250 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 27: * For more than 4 Drives, LSI MegaRaid controller is required, which is included in the C250 performance bundles Configuring LA R250-STND-CNFGW-2 (Step 3) Note on RAID – If customer wishes to configure RAID on their server, the hard drives must be the same speed, size and capacity. Minimum number of Drives per RAID TYPE: RAID 0 – 1 HDD, RAID 1 – 2 HDD, RAID 5 – 3HDD, RAID 6, RAID 10 – 4 HDD Slide 28: Step 5: Select Power Cords (select 2):Default isTwo 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-STND-CNFGW-2 (Step 4-6) Dual Redundant Power Supplies Included with Configuration 750W power supply unit for UCS C250 Rack Server (PID: R250-PSU2-750W) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) R250-PERF-CNFGW Additional Configuration : R250-PERF-CNFGW Additional Configuration 29 Configuring R250-PERF-CNFGW (Steps 1 and 2) : Configuring R250-PERF-CNFGW (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.93GHz Xeon X5670 95W CPU/8MB cache/DDR3 1333MHz Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250 and B250. All DIMMs supported on the C250 M2 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 31: Note on RAID – if customer wishes to configure RAID on their server, the hard drives mush be the same speed, size and capacity. Minimum # HDD needed for RAID: RAID 0 = 1 HDD; RAID 1 = 2 HDD; RAID 5 = 3+ HDD; RAID 6 and RAID 10 = 4+ HDD Configuring R250-PERF-CNFGW (Step 3) Slide 32: Special Notes: on PCIe cards: The C250 M2 can host 4 PCIe option cards (RAID card in 5th slot) All option cards above are “Low Profile/Half-Length Cards. All cards above will fit in either PCIe slots (Low profile or Standard high) Step 5: Select Power Cords (select 2):Default is: Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 M2 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-PERF-CNFGW (Step 4-6) Dual Redundant Power Supplies Included with Configuration 750W power supply unit for UCS C250 Rack Server (PID: R250-PSU2-750W) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) R250-PERF-CNFGW-2 High MemoryAdditional Configuration : R250-PERF-CNFGW-2 High MemoryAdditional Configuration 33 Configuring R250-PERF-CNFGW-2 (Steps 1 and 2) : Configuring R250-PERF-CNFGW-2 (Steps 1 and 2) 128GB 144GB 160GB 192GB 256GB 320GB 384GB Step 1: Dual CPU’s included with configuration: 2x 2.93GHz Xeon X5670 95W CPU/8MB cache/DDR3 1333MHz (PID: A01-X0102) Memory Notes: There are 24 DIMM slots per CPU. System performance is optimized when memory type and quantity is equal for both CPUs DIMMs must be inserted in pairs and from the same DIMM manufacturer, thus the reason for DIMM kits on the C250 M2 and B250 M2. All DIMMs supported on the C250 are Registered (buffered) DIMMs. The following memory capacities supported: 8GB 16GB 32GB 48GB 64GB 80GB 96GB Slide 35: Configuring LA R250-CNFGW-2 (Step 3) Note on RAID – if customer wishes to configure RAID on their server, the hard drives mush be the same speed, size and capacity. Minimum # HDD needed for RAID: RAID 0 = 1 HDD; RAID 1 = 2 HDD; RAID 5 = 3+ HDD; RAID 6 and RAID 10 = 4+ HDD Slide 36: Special Notes: on PCIe cards: The C250 M2 can host 4 PCIe option cards (RAID card in 5th slot) All option cards above are “Low Profile/Half-Length Cards. All cards above will fit in either PCIe slots (Low profile or Standard high) Step 5: Select Power Cords (select 2):Default is: Two 13A, 250V, North America, 2.5m (PID: CABAC-250V/13A) N5000 AC Power Cable, 6A, 250V, North America, 2.5m (PID: CAB-N5K6A-NA) N5000 AC Power Cable, 13A, 250V, North America, 2.5m (PID: CAB-AC-250V/13A) N5000 AC Power Cable, 6A, 250V, Power Strip Type (PID:CAB-C13-C14-JMPR) N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m (PID: SFS-250V-10A-AR) N5000 AC Power Cable, 10A, 250V, Australia, 2.5m (PID: CAB-9K10A-AU) N5000 AC Power Cable, 10A, 250V, China, 2.5m (PID: SFS-250V-10A-CN) N5000 AC Power Cable, 10A, 250V, Europe, 2.5m (PID: CAB-9K10A-EU) N5000 AC Power Cable, 10A, 250V, India, 2.5m (PID: SFS-250V-10A-ID) N5000 AC Power Cable, 10A, 250V, Israel, 2.5m (PID: SFS-250V-10A-IS) N5000 AC Power Cable, 10A, 250V, Italy, 2.5m (PID: CAB-9K10A-IT) N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m (PID: CAB-9K10A-SW) N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m (PID: CAB-9K10A-UK) N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m (PID: CAB-9K12A-NA) Step 6: Cable Management Arm (Min 0/Max 1): Note: Optional – hooks onto the rail kit (a rail kit is included with all C250 servers) and used for cable management Cable Management Arm: (PID: R250-CBLARM) Configuring R250-PERF-CNFGW-2 (Step 4-6) Dual Redundant Power Supplies Included with Configuration 750W power supply unit for UCS C250 Rack Server (PID: R250-PSU2-750W) Rail Kit Included: Rail Kit for the C-Series Rack Server (PID: R250-SLDRAIL) Services and Software : Services and Software 37 Slide 38: MS Windows Server 2003, 2008, Linux, RedHat and Novell SUSe Linux, VMware and BMC Bladelogic (Operations Mgr and Configuration Mgr) – SW license and Service bought at time of UCS Sale. Unified Computing Technical ServicesTake a Systems approach to attaching HW and SW Service – UCS-C Useful Links to UCS Services Sales Acceleration Center http://wwwin.cisco.com/WWSales/wwops/sac/ Services for UCS - internal http://wwwin.cisco.com/CustAdv/services/advtech/datacenter/technologies/unifiedcomputing/ Services for UCS – external http://www.cisco.com/en/US/products/ps10312/serv_group_home.html