ENCLOSED TYPE DSL

Views:
 
Category: Entertainment
     
 

Presentation Description

No description available.

Comments

Presentation Transcript

slide 1:

www.anandsystem.in CHANGING THE WAY YOU THINK ABOUT MOBILE ELECTRIFICATION MANAUFACTURER OF ALL ELECTRICAL CONTROL GEARS FOR EOT CRANE Anand Systems Engineering Pvt . Ltd.

slide 2:

Enclosed Conductor Systems Range – 40Amp to 200Amp The enclosed conductor line SLE is a hazard protected conductor systems for indoor and outdoor installations. It is protected to IP23 standards. The conductor line in a rigid gray PVC housing with different copper cross sections for rated currents of 40Amp to 200Amp. The current collector running in ball bearing are guided by the housing. The main is transferred by spring-stored carbon brushes. A compact design corrosion resistance and easy installation are the main characteristics. General For mobile power consumers like cranes monorails electrical hoists conveyor systems machines tools automated storage retrieval systems lighting systems Etc. Application Gray color plastic housing 4 Mtr standard section. The ground conductors is identified by international color code. Phase reversing prevented by design of the collector and housing. Higher number of conductors possible by combination of several enclosed conductor line. Housing Through plastic joint covers. Coupling Line feeds or end feeds. Feed Sets The open ends of the enclosed conductor are closed by end caps. End Caps Maximum support distance of the conductor is 2 Mtr. Hangers The current collectors are made of re-inforced polyester fiberglass for high strength and light weight. Spring loaded carbon brushes maintain uniform contact. Connecting cables and hinged or flexible towing arms included double collectors for transfer applications and higher amperage Collectors Please Note – for user in galvanizing and pickling plants under aggressive conditions and low voltage applications we would appreciate receiving detailed information especially for the environmental conditions.

slide 3:

System Arrangement Drawing

slide 4:

TECHNICAL DATA SHEET CONDUCTOR BAR COPPER Nominal Current 40A 60A 80A 100A 120A 140A 160 200A Cross Sectional Area DC Resistance Ω/M + 35 °C 0.0019 0.0011 0.0008 0.0007 0.000549 0.0003 0.0003 0.0002 Impedence Ω/M + 35 °C 0.0021 0.0012 0.0009 0.0007 0.000568 0.0004 0.0003 0.0002 Support Pitch Standard 1500MM Lateral 1500MM Protection Class Finger Safe IP21 Conductor Joint Bolted Type and Jointless CONDUCTOR BAR COVER Standard Insulation PVC Dielectric Strength 180 kv/cm Maximum System Working Temperature 80°C Flame Test Self Extinguishing Colour GRAY INSTALLATION Hanger Clamps 1pole Power Feeding At joint or at any location Installation suitable for Indoor / outdoor Note :- 1 Each bar Length is 4Mtr. 2 Maximum Systems Volage is 500V Ac / 600V Dc 3 High Voltage with Stand For 1 Min Flashover Test is 2.5KV / 7.5KV

authorStream Live Help