logging in or signing up Electrical Safety - Construction aSGuest67357 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 735 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: September 17, 2010 This Presentation is Public Favorites: 1 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Electrical Safety - Construction : Barve associates Training & Education 1 Electrical Safety - Construction Electricity - The Dangers : Barve associates Training & Education 2 Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes very little electricity to cause harm Significant risk of causing fires Electricity – How it Works : Barve associates Training & Education 3 Electricity – How it Works Electricity is the flow of energy from one place to another Requires a source of power: usually a generating station A flow of electrons (current) travels through a conductor Travels in a closed circuit Electrical Terms : Barve associates Training & Education 4 Electrical Terms Current -- electrical movement (measured in amps) Circuit -- complete path of the current. Includes electricity source, a conductor, and the output device or load (such as a lamp, tool, or heater) Resistance -- restriction to electrical flow Conductors – substances, like metals, with little resistance to electricity that allow electricity to flow Grounding – a conductive connection to the earth which acts as a protective measure Insulators -- substances with high resistance to electricity like glass, porcelain, plastic, and dry wood that prevent electricity from getting to unwanted areas Electrical Injuries : Barve associates Training & Education 5 Electrical Injuries There are four main types of electrical injuries: Direct: Electrocution or death due to electrical shock Electrical shock Burns Indirect - Falls Electrical Shock : Barve associates Training & Education 6 Electrical Shock An electrical shock is received when electrical current passes through the body. You will get an electrical shock if a part of your body completes an electrical circuit by… Touching a live wire and an electrical ground, or Touching a live wire and another wire at a different voltage. Shock Severity : Barve associates Training & Education 7 Shock Severity Severity of the shock depends on: Path of current through the body Amount of current flowing through the body (amps) Duration of the shocking current through the body, LOW VOLTAGE DOES NOT MEAN LOW HAZARD Dangers of Electrical Shock : Barve associates Training & Education 8 Dangers of Electrical Shock Currents above 10 mA* can paralyze or “freeze” muscles. Currents more than 75 mA can cause a rapid, ineffective heartbeat -- death will occur in a few minutes unless a defibrillator is used 75 mA is not much current – a small power drill uses 30 times as much * mA = milliampere = 1/1,000 of an ampere Defibrillator in use Burns : Barve associates Training & Education 9 Burns Most common shock-related injury Occurs when you touch electrical wiring or equipment that is improperly used or maintained Typically occurs on hands Very serious injury that needs immediate attention Falls : Barve associates Training & Education 10 Falls Electric shock can also cause indirect injuries Workers in elevated locations who experience a shock may fall, resulting in serious injury or death Electrical Hazards and How to Control Them : Barve associates Training & Education 11 Electrical Hazards and How to Control Them Electrical accidents are caused by a combination of three factors: Unsafe equipment and/or installation, Workplaces made unsafe by the environment, and Unsafe work practices. Hazard – Exposed Electrical Parts : Barve associates Training & Education 12 Hazard – Exposed Electrical Parts Cover removed from wiring or breaker box Control – Isolate Electrical Parts : Barve associates Training & Education 13 Control – Isolate Electrical Parts Use guards or barriers Replace covers Guard live parts of electric equipment operating at 50 volts or more against accidental contact Control – Isolate Electrical Parts - Cabinets, Boxes & Fittings : Barve associates Training & Education 14 Control – Isolate Electrical Parts - Cabinets, Boxes & Fittings Conductors going into them must be protected, and unused openings must be closed Control – Close Openings : Barve associates Training & Education 15 Control – Close Openings Junction boxes, pull boxes and fittings must have approved covers Unused openings in cabinets, boxes and fittings must be closed (no missing knockouts) Photo shows violations of these two requirements Hazard - Overhead Power Lines : Barve associates Training & Education 16 Hazard - Overhead Power Lines Usually not insulated Examples of equipment that can contact power lines: Crane Ladder Scaffold Backhoe Scissors lift Raised dump truck bed Aluminum paint roller Control - Overhead Power Lines : Barve associates Training & Education 17 Control - Overhead Power Lines Stay at least 10 feet away Post warning signs Assume that lines are energized Use wood or fiberglass ladders, not metal Power line workers need special training & PPE Hazard - Inadequate Wiring : Barve associates Training & Education 18 Hazard - Inadequate Wiring Hazard - wire too small for the current Example - portable tool with an extension cord that has a wire too small for the tool The tool will draw more current than the cord can handle, causing overheating and a possible fire without tripping the circuit breaker The circuit breaker could be the right size for the circuit but not for the smaller-wire extension cord Wire gauge measures wires ranging in size from number 36 to 0 American wire gauge (AWG) Control – Use the Correct Wire : Barve associates Training & Education 19 Control – Use the Correct Wire Wire used depends on operation, building materials, electrical load, and environmental factors Use fixed cords rather than flexible cords Use the correct extension cord Must be 3-wire type and designed for hard or extra-hard use Hazard – Defective Cords & Wires : Barve associates Training & Education 20 Hazard – Defective Cords & Wires Plastic or rubber covering is missing Damaged extension cords & tools Hazard – Damaged Cords : Barve associates Training & Education 21 Hazard – Damaged Cords Cords can be damaged by: Aging Door or window edges Staples or fastenings Abrasion from adjacent materials Activity in the area Improper use can cause shocks, burns or fire Control – Cords & Wires : Barve associates Training & Education 22 Control – Cords & Wires Insulate live wires Check before use Use only cords that are 3-wire type Use only cords marked for hard or extra-hard usage Use only cords, connection devices, and fittings equipped with strain relief Remove cords by pulling on the plugs, not the cords Cords not marked for hard or extra-hard use, or which have been modified, must be taken out of service immediately Permissible Use of Flexible Cords : Barve associates Training & Education 23 Permissible Use of Flexible Cords Stationary equipment-to facilitate interchange DO NOT use flexible wiring where frequent inspection would be difficult or where damage would be likely. Flexible cords must not be . . . run through holes in walls, ceilings, or floors; run through doorways, windows, or similar openings (unless physically protected); hidden in walls, ceilings, floors, conduit or other raceways. Grounding : Barve associates Training & Education 24 Grounding Grounding creates a low-resistance path from a tool to the earth to disperse unwanted current. When a short or lightning occurs, energy flows to the ground, protecting you from electrical shock, injury and death. Hazard – Improper Grounding : Barve associates Training & Education 25 Hazard – Improper Grounding Tools plugged into improperly grounded circuits may become energized Broken wire or plug on extension cord Some of the most frequently violated OSHA standards Control – Ground Tools & Equipment : Barve associates Training & Education 26 Control – Ground Tools & Equipment Ground power supply systems, electrical circuits, and electrical equipment Frequently inspect electrical systems to insure path to ground is continuous Inspect electrical equipment before use Don’t remove ground prongs from tools or extension cords Ground exposed metal parts of equipment Control – Use GFCI (ground-fault circuit interrupter) : Barve associates Training & Education 27 Control – Use GFCI (ground-fault circuit interrupter) Protects you from shock Detects difference in current between the black and white wires If ground fault detected, GFCI shuts off electricity in 1/40th of a second Use GFCI’s on all 120-volt, single-phase, 15- and 20-ampere receptacles, or have an assured equipment grounding conductor program. Control - Assured Equipment Grounding Conductor Program : Barve associates Training & Education 28 Control - Assured Equipment Grounding Conductor Program Program must cover: All cord sets Receptacles not part of a building or structure Equipment connected by plug and cord Program requirements include: Specific procedures adopted by the employer Competent person to implement the program Visual inspection for damage of equipment connected by cord and plug Hazard – Overloaded Circuits : Barve associates Training & Education 29 Hazard – Overloaded Circuits Hazards may result from: Too many devices plugged into a circuit, causing heated wires and possibly a fire Damaged tools overheating Lack of overcurrent protection Wire insulation melting, which may cause arcing and a fire in the area where the overload exists, even inside a wall Control - Electrical Protective Devices : Barve associates Training & Education 30 Control - Electrical Protective Devices Automatically opens circuit if excess current from overload or ground-fault is detected – shutting off electricity Includes GFCI’s, fuses, and circuit breakers Fuses and circuit breakers are overcurrent devices. When too much current: Fuses melt Circuit breakers trip open Power Tool Requirements : Barve associates Training & Education 31 Power Tool Requirements Have a three-wire cord with ground plugged into a grounded receptacle, or Be double insulated, or Be powered by a low-voltage isolation transformer Tool Safety Tips : Barve associates Training & Education 32 Tool Safety Tips Use gloves and appropriate footwear Store in dry place when not using Don’t use in wet/damp conditions Keep working areas well lit Ensure not a tripping hazard Don’t carry a tool by the cord Don’t yank the cord to disconnect it Keep cords away from heat, oil, & sharp edges Disconnect when not in use and when changing accessories such as blades & bits Remove damaged tools from use Preventing Electrical Hazards - Tools : Barve associates Training & Education 33 Preventing Electrical Hazards - Tools Inspect tools before use Use the right tool correctly Protect your tools Use double insulated tools Double Insulated marking Temporary Lights : Barve associates Training & Education 34 Temporary Lights Protect from contact and damage, and don’t suspend by cords unless designed to do so. Clues that Electrical Hazards Exist : Barve associates Training & Education 35 Clues that Electrical Hazards Exist Tripped circuit breakers or blown fuses Warm tools, wires, cords, connections, or junction boxes GFCI that shuts off a circuit Worn or frayed insulation around wire or connection Lockout and Tagging of Circuits : Barve associates Training & Education 36 Lockout and Tagging of Circuits Apply locks to power source after de-energizing Tag deactivated controls Tag de-energized equipment and circuits at all points where they can be energized Tags must identify equipment or circuits being worked on Safety-Related Work Practices : Barve associates Training & Education 37 Safety-Related Work Practices To protect workers from electrical shock: Use barriers and guards to prevent passage through areas of exposed energized equipment Pre-plan work, post hazard warnings and use protective measures Keep working spaces and walkways clear of cords Safety-Related Work Practices : Barve associates Training & Education 38 Safety-Related Work Practices Use special insulated tools when working on fuses with energized terminals Don’t use worn or frayed cords and cables Don’t fasten extension cords with staples, hang from nails, or suspend by wire. Preventing Electrical Hazards - Planning : Barve associates Training & Education 39 Preventing Electrical Hazards - Planning Plan your work with others Plan to avoid falls Plan to lock-out and tag-out equipment Remove jewelry Avoid wet conditions and overhead power lines Avoid Wet Conditions : Barve associates Training & Education 40 Avoid Wet Conditions If you touch a live wire or other electrical component while standing in even a small puddle of water you’ll get a shock. Damaged insulation, equipment, or tools can expose you to live electrical parts. Improperly grounded metal switch plates & ceiling lights are especially hazardous in wet conditions. Wet clothing, high humidity, and perspiration increase your chances of being electrocuted. Preventing Electrical Hazards - PPE : Barve associates Training & Education 41 Preventing Electrical Hazards - PPE Proper foot protection (not tennis shoes) Rubber insulating gloves, hoods, sleeves, matting, and blankets Hard hat (insulated - nonconductive) Preventing Electrical Hazards – Proper Wiring and Connectors : Barve associates Training & Education 42 Preventing Electrical Hazards – Proper Wiring and Connectors Use and test GFCI’s Check switches and insulation Use three prong plugs Use extension cords only when necessary & assure in proper condition and right type for job Use correct connectors Training : Barve associates Training & Education 43 Training Deenergize electric equipment before inspecting or repairing Using cords, cables, and electric tools that are in good repair Lockout / Tagout recognition and procedures Use appropriate protective equipment Train employees working with electric equipment in safe work practices, including: Summary – Hazards & Protections : Barve associates Training & Education 44 Summary – Hazards & Protections Hazards Inadequate wiring Exposed electrical parts Wires with bad insulation Ungrounded electrical systems and tools Overloaded circuits Damaged power tools and equipment Using the wrong PPE and tools Overhead powerlines All hazards are made worse in wet conditions Protective Measures Proper grounding Use GFCI’s Use fuses and circuit breakers Guard live parts Lockout/Tagout Proper use of flexible cords Close electric panels Training Summary : Barve associates Training & Education 45 Summary Electrical equipment must be: Listed and labeled Free from hazards Used in the proper manner If you use electrical tools you must be: Protected from electrical shock Provided necessary safety equipment You do not have the permission to view this presentation. In order to view it, please contact the author of the presentation.
Electrical Safety - Construction aSGuest67357 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 735 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: September 17, 2010 This Presentation is Public Favorites: 1 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Electrical Safety - Construction : Barve associates Training & Education 1 Electrical Safety - Construction Electricity - The Dangers : Barve associates Training & Education 2 Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes very little electricity to cause harm Significant risk of causing fires Electricity – How it Works : Barve associates Training & Education 3 Electricity – How it Works Electricity is the flow of energy from one place to another Requires a source of power: usually a generating station A flow of electrons (current) travels through a conductor Travels in a closed circuit Electrical Terms : Barve associates Training & Education 4 Electrical Terms Current -- electrical movement (measured in amps) Circuit -- complete path of the current. Includes electricity source, a conductor, and the output device or load (such as a lamp, tool, or heater) Resistance -- restriction to electrical flow Conductors – substances, like metals, with little resistance to electricity that allow electricity to flow Grounding – a conductive connection to the earth which acts as a protective measure Insulators -- substances with high resistance to electricity like glass, porcelain, plastic, and dry wood that prevent electricity from getting to unwanted areas Electrical Injuries : Barve associates Training & Education 5 Electrical Injuries There are four main types of electrical injuries: Direct: Electrocution or death due to electrical shock Electrical shock Burns Indirect - Falls Electrical Shock : Barve associates Training & Education 6 Electrical Shock An electrical shock is received when electrical current passes through the body. You will get an electrical shock if a part of your body completes an electrical circuit by… Touching a live wire and an electrical ground, or Touching a live wire and another wire at a different voltage. Shock Severity : Barve associates Training & Education 7 Shock Severity Severity of the shock depends on: Path of current through the body Amount of current flowing through the body (amps) Duration of the shocking current through the body, LOW VOLTAGE DOES NOT MEAN LOW HAZARD Dangers of Electrical Shock : Barve associates Training & Education 8 Dangers of Electrical Shock Currents above 10 mA* can paralyze or “freeze” muscles. Currents more than 75 mA can cause a rapid, ineffective heartbeat -- death will occur in a few minutes unless a defibrillator is used 75 mA is not much current – a small power drill uses 30 times as much * mA = milliampere = 1/1,000 of an ampere Defibrillator in use Burns : Barve associates Training & Education 9 Burns Most common shock-related injury Occurs when you touch electrical wiring or equipment that is improperly used or maintained Typically occurs on hands Very serious injury that needs immediate attention Falls : Barve associates Training & Education 10 Falls Electric shock can also cause indirect injuries Workers in elevated locations who experience a shock may fall, resulting in serious injury or death Electrical Hazards and How to Control Them : Barve associates Training & Education 11 Electrical Hazards and How to Control Them Electrical accidents are caused by a combination of three factors: Unsafe equipment and/or installation, Workplaces made unsafe by the environment, and Unsafe work practices. Hazard – Exposed Electrical Parts : Barve associates Training & Education 12 Hazard – Exposed Electrical Parts Cover removed from wiring or breaker box Control – Isolate Electrical Parts : Barve associates Training & Education 13 Control – Isolate Electrical Parts Use guards or barriers Replace covers Guard live parts of electric equipment operating at 50 volts or more against accidental contact Control – Isolate Electrical Parts - Cabinets, Boxes & Fittings : Barve associates Training & Education 14 Control – Isolate Electrical Parts - Cabinets, Boxes & Fittings Conductors going into them must be protected, and unused openings must be closed Control – Close Openings : Barve associates Training & Education 15 Control – Close Openings Junction boxes, pull boxes and fittings must have approved covers Unused openings in cabinets, boxes and fittings must be closed (no missing knockouts) Photo shows violations of these two requirements Hazard - Overhead Power Lines : Barve associates Training & Education 16 Hazard - Overhead Power Lines Usually not insulated Examples of equipment that can contact power lines: Crane Ladder Scaffold Backhoe Scissors lift Raised dump truck bed Aluminum paint roller Control - Overhead Power Lines : Barve associates Training & Education 17 Control - Overhead Power Lines Stay at least 10 feet away Post warning signs Assume that lines are energized Use wood or fiberglass ladders, not metal Power line workers need special training & PPE Hazard - Inadequate Wiring : Barve associates Training & Education 18 Hazard - Inadequate Wiring Hazard - wire too small for the current Example - portable tool with an extension cord that has a wire too small for the tool The tool will draw more current than the cord can handle, causing overheating and a possible fire without tripping the circuit breaker The circuit breaker could be the right size for the circuit but not for the smaller-wire extension cord Wire gauge measures wires ranging in size from number 36 to 0 American wire gauge (AWG) Control – Use the Correct Wire : Barve associates Training & Education 19 Control – Use the Correct Wire Wire used depends on operation, building materials, electrical load, and environmental factors Use fixed cords rather than flexible cords Use the correct extension cord Must be 3-wire type and designed for hard or extra-hard use Hazard – Defective Cords & Wires : Barve associates Training & Education 20 Hazard – Defective Cords & Wires Plastic or rubber covering is missing Damaged extension cords & tools Hazard – Damaged Cords : Barve associates Training & Education 21 Hazard – Damaged Cords Cords can be damaged by: Aging Door or window edges Staples or fastenings Abrasion from adjacent materials Activity in the area Improper use can cause shocks, burns or fire Control – Cords & Wires : Barve associates Training & Education 22 Control – Cords & Wires Insulate live wires Check before use Use only cords that are 3-wire type Use only cords marked for hard or extra-hard usage Use only cords, connection devices, and fittings equipped with strain relief Remove cords by pulling on the plugs, not the cords Cords not marked for hard or extra-hard use, or which have been modified, must be taken out of service immediately Permissible Use of Flexible Cords : Barve associates Training & Education 23 Permissible Use of Flexible Cords Stationary equipment-to facilitate interchange DO NOT use flexible wiring where frequent inspection would be difficult or where damage would be likely. Flexible cords must not be . . . run through holes in walls, ceilings, or floors; run through doorways, windows, or similar openings (unless physically protected); hidden in walls, ceilings, floors, conduit or other raceways. Grounding : Barve associates Training & Education 24 Grounding Grounding creates a low-resistance path from a tool to the earth to disperse unwanted current. When a short or lightning occurs, energy flows to the ground, protecting you from electrical shock, injury and death. Hazard – Improper Grounding : Barve associates Training & Education 25 Hazard – Improper Grounding Tools plugged into improperly grounded circuits may become energized Broken wire or plug on extension cord Some of the most frequently violated OSHA standards Control – Ground Tools & Equipment : Barve associates Training & Education 26 Control – Ground Tools & Equipment Ground power supply systems, electrical circuits, and electrical equipment Frequently inspect electrical systems to insure path to ground is continuous Inspect electrical equipment before use Don’t remove ground prongs from tools or extension cords Ground exposed metal parts of equipment Control – Use GFCI (ground-fault circuit interrupter) : Barve associates Training & Education 27 Control – Use GFCI (ground-fault circuit interrupter) Protects you from shock Detects difference in current between the black and white wires If ground fault detected, GFCI shuts off electricity in 1/40th of a second Use GFCI’s on all 120-volt, single-phase, 15- and 20-ampere receptacles, or have an assured equipment grounding conductor program. Control - Assured Equipment Grounding Conductor Program : Barve associates Training & Education 28 Control - Assured Equipment Grounding Conductor Program Program must cover: All cord sets Receptacles not part of a building or structure Equipment connected by plug and cord Program requirements include: Specific procedures adopted by the employer Competent person to implement the program Visual inspection for damage of equipment connected by cord and plug Hazard – Overloaded Circuits : Barve associates Training & Education 29 Hazard – Overloaded Circuits Hazards may result from: Too many devices plugged into a circuit, causing heated wires and possibly a fire Damaged tools overheating Lack of overcurrent protection Wire insulation melting, which may cause arcing and a fire in the area where the overload exists, even inside a wall Control - Electrical Protective Devices : Barve associates Training & Education 30 Control - Electrical Protective Devices Automatically opens circuit if excess current from overload or ground-fault is detected – shutting off electricity Includes GFCI’s, fuses, and circuit breakers Fuses and circuit breakers are overcurrent devices. When too much current: Fuses melt Circuit breakers trip open Power Tool Requirements : Barve associates Training & Education 31 Power Tool Requirements Have a three-wire cord with ground plugged into a grounded receptacle, or Be double insulated, or Be powered by a low-voltage isolation transformer Tool Safety Tips : Barve associates Training & Education 32 Tool Safety Tips Use gloves and appropriate footwear Store in dry place when not using Don’t use in wet/damp conditions Keep working areas well lit Ensure not a tripping hazard Don’t carry a tool by the cord Don’t yank the cord to disconnect it Keep cords away from heat, oil, & sharp edges Disconnect when not in use and when changing accessories such as blades & bits Remove damaged tools from use Preventing Electrical Hazards - Tools : Barve associates Training & Education 33 Preventing Electrical Hazards - Tools Inspect tools before use Use the right tool correctly Protect your tools Use double insulated tools Double Insulated marking Temporary Lights : Barve associates Training & Education 34 Temporary Lights Protect from contact and damage, and don’t suspend by cords unless designed to do so. Clues that Electrical Hazards Exist : Barve associates Training & Education 35 Clues that Electrical Hazards Exist Tripped circuit breakers or blown fuses Warm tools, wires, cords, connections, or junction boxes GFCI that shuts off a circuit Worn or frayed insulation around wire or connection Lockout and Tagging of Circuits : Barve associates Training & Education 36 Lockout and Tagging of Circuits Apply locks to power source after de-energizing Tag deactivated controls Tag de-energized equipment and circuits at all points where they can be energized Tags must identify equipment or circuits being worked on Safety-Related Work Practices : Barve associates Training & Education 37 Safety-Related Work Practices To protect workers from electrical shock: Use barriers and guards to prevent passage through areas of exposed energized equipment Pre-plan work, post hazard warnings and use protective measures Keep working spaces and walkways clear of cords Safety-Related Work Practices : Barve associates Training & Education 38 Safety-Related Work Practices Use special insulated tools when working on fuses with energized terminals Don’t use worn or frayed cords and cables Don’t fasten extension cords with staples, hang from nails, or suspend by wire. Preventing Electrical Hazards - Planning : Barve associates Training & Education 39 Preventing Electrical Hazards - Planning Plan your work with others Plan to avoid falls Plan to lock-out and tag-out equipment Remove jewelry Avoid wet conditions and overhead power lines Avoid Wet Conditions : Barve associates Training & Education 40 Avoid Wet Conditions If you touch a live wire or other electrical component while standing in even a small puddle of water you’ll get a shock. Damaged insulation, equipment, or tools can expose you to live electrical parts. Improperly grounded metal switch plates & ceiling lights are especially hazardous in wet conditions. Wet clothing, high humidity, and perspiration increase your chances of being electrocuted. Preventing Electrical Hazards - PPE : Barve associates Training & Education 41 Preventing Electrical Hazards - PPE Proper foot protection (not tennis shoes) Rubber insulating gloves, hoods, sleeves, matting, and blankets Hard hat (insulated - nonconductive) Preventing Electrical Hazards – Proper Wiring and Connectors : Barve associates Training & Education 42 Preventing Electrical Hazards – Proper Wiring and Connectors Use and test GFCI’s Check switches and insulation Use three prong plugs Use extension cords only when necessary & assure in proper condition and right type for job Use correct connectors Training : Barve associates Training & Education 43 Training Deenergize electric equipment before inspecting or repairing Using cords, cables, and electric tools that are in good repair Lockout / Tagout recognition and procedures Use appropriate protective equipment Train employees working with electric equipment in safe work practices, including: Summary – Hazards & Protections : Barve associates Training & Education 44 Summary – Hazards & Protections Hazards Inadequate wiring Exposed electrical parts Wires with bad insulation Ungrounded electrical systems and tools Overloaded circuits Damaged power tools and equipment Using the wrong PPE and tools Overhead powerlines All hazards are made worse in wet conditions Protective Measures Proper grounding Use GFCI’s Use fuses and circuit breakers Guard live parts Lockout/Tagout Proper use of flexible cords Close electric panels Training Summary : Barve associates Training & Education 45 Summary Electrical equipment must be: Listed and labeled Free from hazards Used in the proper manner If you use electrical tools you must be: Protected from electrical shock Provided necessary safety equipment