logging in or signing up Analy_Meth_Dev aSGuest120088 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 16 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: November 22, 2011 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Pharmaceutical Development with Focus on Paediatric formulations: Pharmaceutical Development with Focus on Paediatric formulations WHO/FIP Training Workshop Hyatt Regency Hotel Sahar Airport Road Andheri East, Mumbai, India 28 April 2008 – 2 May 2008Analytical Method Development: Analytical Method Development Presented by: Birgit Schmauser, PhD Federal Institute for Drugs and Medical Devices (BfArM) b.schmauser@bfarm.deAnalytical Method Development: Analytical Method Development In this presentation: Standards in developing analytical methods for Originator and multisource generic FPPs Specifications Stability Parallel development of analytical methods for cleaning validationAnalytical Method Development: Analytical Method Development Originator , First-time Generic and Multisource Generic Multisource Generic First-time Generic Originator Pharmacopoeias Information from regulatory agencies (publicly available) & literature data Originator´s specifications API quality standards Pharmacopoeias Information from regulatory agencies (publicly available) & literature data Originator´s specifications FPP quality standards Verify identity, potency, purity of API and FPP by pharmacopoeial methods and in-house methods Derive identity, potency, purity of API and FPP by in house methods Establish identity, potency, purity of API and FPP by in-house methods Analytical methodsAnalytical Method Development: Analytical Method Development HPLC-method to assay potency and purity – risk assessment Multisource Generic First-time Generic Originator Selectively screen /detect any impurity or degradant Establish potency Identify impurities/degradants Verify impurities from Pharmacopoeia Characterise „in-house“ impurities/degradants (Response factors) Derive impurities/degradants from Originator Characterize „in-house“ impurities/degradants Calculate response factors Characterise all impurities/degradants Calculate Response factors (qualification by clinical use) Use pharmacopoeial reference materials Extract (& reproduce ) reference materials Establish reference materials „Implement“ for routine use Adapt /modify to/for routine use Adapt to routine useAnalytical Method Development: Analytical Method Development Interchangeability (IC) of multisource generic FPPs ( Essential similarity with Innovator FPP) Pharmaceutical + Bioequivalence Equivalence IC = PE + BEAnalytical Method Development: Analytical Method Development Pharmaceutical equivalence FPPs meet the same or comparable standards by use of equivalent analytical methods Same API ( chemical and physical equivalence) Same dosage form and route of administration Same strength Comparable labeling Equivalence in pharmaceutical development Equivalence in stability Equivalence in manufacture (WHO-GMP)Analytical Method Development: Analytical Method Development Prequalification requirements Validation of analytical methods is a prerequisite for prequalification of product dossiers Non-compendial APIs and FPPs are tested with methods developed by the manufacturer For compendial APIs and FPPs the „applicability“ of pharmacopoeial methods to particular products must be demonstrated (verification) Analytical methods must be developed and validated according to TRS 823, Annex 5, Validation of analytical procedures used in the examination of pharmaceutical materials ; ICH Q2 (R1) To be used within GLP and GMP environmentsAnalytical Method Development: Analytical Method Development METHODS PHARMACEUTICAL CLINICAL At initial phase of pharmaceutical development To understand the profile of related substances and to study stability To start measuring the impact of key product and manufacturing process parameters on consistent FPP quality To develop a stable and reproducible formulation for the manufacture of bioequivalence, dissolution, stability and pilot-scale validation batches To determine bioavailability in healthy volunteers At advanced phase of pharmaceutical development To be robust, transferable, accurate and precise for specification setting, stability assessment and QC release of prequalified product batches To optimise , scale-up and transfer a stable and controlled manufacturing process for the prequalification product To prove bioequivalence after critical variations to the prequalified dossier Use of analytical methods - genericsAnalytical Method Development: Analytical Method Development Prerequisites for analytical method validation Six “ M ”s Quality of the analytical method M an M achine qualified calibrated robust qualified M ethods suitable characterised documented M ilieu M aterial M anagement Quality Reference standards Tempe- rature Analysts´ support skilled Humidity Vibrations Time Supplies Irradi- ationsAnalytical Method Development: Analytical Method Development Method development life cycle Planning Development and Validation Policy Objectives/Requirements of Method Information Gathering Resource Gathering Method development Initital Method Development Pre-Validation Evaluation Method Optimization Robustness System Suitability Development Plan – Project Customer Evaluation Testing Validation Experiments Method Transfer Experiments Filed Method in Use Periodically Monitoring/Review of Methods in Control Labs From: Analytical Chemistry in a GMP Environment . Edited by J.M. Miller and J.B. Crowther, ISBN 0-471-31431-5, Wiley & Sons Inc.Analytical Method Development: Analytical Method Development Validation should verify the suitability of an analytical method for its intended purpose Validation should be founded on method development performed beforehand that suggest the suitability and robustness of the method Validation may be performed in different ways (individual purpose) according to common standardsSlide 13: Validation protocol Method principle / objective Listing of responsibilities Laboratories involved and their role in the validation Method categorization List of reagents (including test lots) and standards Test procedures to evaluate each validation parameter and proposed acceptance criteria Plan or procedure when acceptance criteria are not met Requirements for the final report The validation process cannot proceed until the protocol and all parties involved approve the acceptance criteriaAnalytical Method Development: Analytical Method Development Innovator versus Generics Generics Innovator - + R & D on API - + Preclinical trials - Method validation summary Clinical trials phase I and II - Method validation completed Clinical trials phase III - Validated methods Post marketing phase IV Validated methods: GMP and GLP Validated methods Entering of Generics; Pharmaceutical development, Comparability with InnovatorAnalytical Method Development: Analytical Method Development Validation Characteristics Assay Impurities Identification limit quantitative + - + - Accuracy + - + - Precision + + + + Specificity - + - - Detection Limit - - + - Quantitation Limit + - + - Linearity + - + - Range + + + + RobustnessAnalytical Method Development: Analytical Method Development Accuracy and precision Accurate & precise Accurate & imprecise Inaccurate & precise Inaccurate & impreciseAnalytical Method Development: Analytical Method Development Precision Expresses the closeness of agreement between a series of measurements obtained from multiple sampling of the same homogenous sample Is usually expressed as the standard deviation (S), variance (S 2 ) or coefficient of variation (RSD) of a series of measurements Precision may be considered at three levels Repeatability (intra-assay precision) Intermediate Precision (variability within a laboratory) Reproducibility (precision between laboratories)Analytical Method Development: Analytical Method Development Normal distribution, probability function [P(x)] and confidence interval [CI] Probability (P) , that measurements from a normal distribution fall within [µ-x n , µ+x n ] for x n = n s is described by the “ erf -function” ( µ = mean) : An interval of ± 3 s covers 99.73% of values Number of times each value occurs P x n 0.6826895 s 0.9544997 2s 0.9973002 3s 0.9999366 4s 0.9999994 5s Values s 2s 3s s 2s 3sAnalytical Method Development: Analytical Method Development Normal distribution, probability function [P(x)] and confidence interval [CI] Probability-P Confidence interval [CI] centered around the mean [µ] in units of sigma [ s ] described by “inverse erf -function”: A CI of 95% includes values ± 1.95 s around the mean x p P 1.28155 s 0.800 1.64485 s 0.900 1.95996 s 0.950 2.57583 s 0.995 3.29053 s 0.999Analytical Method Development: Analytical Method Development Relationship of variability, probability and reliability of data High variability of data (large s ) generate large confidence intervals and thus lower the reliability of the mean Low variability of data (small s) generate small confidence intervals and thus increase the reliability of the meanAnalytical Method Development: Analytical Method Development Repeatability Six replicate sample preparation steps from a homogenously prepared tablet mixture (nominal value of API 150 mg) Assay Peak area Injection 147.10 mg/98.06% 173865 1 148.00 mg/98.66% 174926 2 146.32 mg/97.54% 172933 3 148.08 mg/98.72% 175011 4 151.95 mg/101.30% 179557 5 149.28 mg/99.52% 176425 6 148.45 mg/98.96% 175453 Mean 1.98 mg/1.32% 2329 SD ( s ) 1.32% 1.32% RSD Mean ± 3 SD = Confidence interval of 99.73% 98.96 ± 3x1.32% = 95% - 102.92%Analytical Method Development: Analytical Method Development Intermediate precision Expresses within-laboratories variations (different days, different analysts, different equipment etc.) Peak area analyst 3 Peak area analyst 2 Peak area analyst 1 Injection 177965 175656 173865 1 178556 175878 174926 2 177342 176004 172933 3 178011 176344 175011 4 179466 175332 179557 5 179688 174959 176425 6 178504 175695 175453 Mean 918 495 2329 SD ( s ) 0.51% 0.28% 1.32% RSD Analyst 1: 98.96% ± 3 x 1.32% Analyst 2: 99.12% ± 3 x 0.28 Analyst 3: 100.70% ± 3 x 0.51 Average of 3 analysts ± 3SD : 95% - 102.23% Mean ± 3 SD: (177252 100%)Analytical Method Development: Analytical Method Development Reproducibility Expresses the precision between laboratories Collaborative studies, usually applied to standardisation of methodology Transfer of technology Compendial methodsAnalytical Method Development: Analytical Method Development Accuracy Expresses the closeness of agreement between the value which is accepted either as a conventional true value or an accepted reference value and the value found Sometimes referred to as „ TRUENESS “ true meanAnalytical Method Development: Analytical Method Development To find out whether a method is accurate: Drug substance (assay) Application of the method to an analyte of known purity (e.g. reference substance) Comparison of the results of one method with those of a second well-characterised method (accuracy known) Drug product (assay) Application of the method to synthetic mixtures of the drug product component to which known quantities of the analyte have been added Drug product may exceptionally be used as matrix Drug substance/Drug product (Impurities) Application of the method to samples spiked with known amounts of impuritiesAnalytical Method Development: Analytical Method Development Accuracy : Application of the method to synthetic mixtures of the drug product components to which known quantities of the analyte have been added Recovery reduced by ~10 – 15% From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development When to expect Accuracy problems Insufficient selectivity of the method Impurity peaks are not resolved and account for assay value Recovery is < 100% Irreversible adsorption of analyte to surfaces of the system Incorrect assay value of a reference standard Due to decomposition of reference standard Incorrect assay value due to change in matrix Analytical laboratory still uses the preceding matrix as standardAnalytical Method Development: Analytical Method Development Specificity Is the ability to assess unequivocally the analyte in the presence of components which may be expected to be present (impurities, degradants, matrix…) Identity testing To ensure the identity of an analyte Purity testing To ensure accurate statement on the content of impurities of an analyte Assay To allow an accurate statement on the content of an analyte in a sampleAnalytical Method Development: Analytical Method Development Specificity: Overlay chromatogram of an impurity solution with a sample solution From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development Specificity and stability Stress stability testing to ensure the stability indicating potential of an analytical method Apply diverse stress factors to the API Apply diverse stress factors to the FPP Stress conditions: e.g. Supplement 2 of Generic Guideline; TRS 929, Annex 5 Assure that the API can be assessed specifically in the presence of known and unknown (generated by stress) impurities Assure that known impurities/degradants can be specifically assessed in the presence of further degradants By peak purity assessment and (overlay of) chromatogramsAnalytical Method Development: Analytical Method Development Stress stability studies versus forced degradation studies Stress stability (5 – 15% decomposition) Forced degradation Stress parameter pH ± 2 (2 weeks) 0.2 ml 1N HCl / 5 ml API-solution / 3h, 6h , 12h, 24h…7d (RT & 60°C) Acid pH ± 10 (2 weeks) 0.2 ml 1N NaOH / 5 ml API-solution / 3h, 6h , 12h, 24h…7d (RT & 60°C) Base 1 g/ml oxygen bubbled through (8 hours) 0.1 – 2% H 2 O 2 (24 hours) 0.2 ml 5% or 35% H 2 O 2 / 5 ml API-solution (RT, to 7d & 60°C, 3h ) H 2 O 2 / Oxygen - 60°C / 5 ml solution ( 3h, 6h …7d) Heat 60°C (4 weeks) 105° C / solid API ( 1d and 7d) Heat 365 nm or white fluorescent light / solid API ( 1d and 7d) UV or Light 50°C / 80% RH (4 weeks) - HumidityAnalytical Method Development: Analytical Method Development Limit of Detection (LOD, DL) The LOD of an analytical procedure is the lowest amount of analyte in sample which can be detected but not necessarily quantitated as an exact value Determination is usually based on Signal to noise ratio (~3:1) ( baseline noise ) or Standard deviation of response ( s ) and Slope (S) 3.3 s /SAnalytical Method Development: Analytical Method Development Limit of Quantitation (LOQ, QL) The LOQ is the lowest amount of analyte in a sample which can be quantitatively determined with suitable precision and accuracy The quantitation limit is used particularly for the determination of impurities and/or degradation products Determination is usually based on Signal to noise ratio (~10:1) ( baseline noise ) or Standard deviation of response ( s ) and Slope (S) 10 s/ SAnalytical Method Development: Analytical Method Development Noise LOD Signal to Noise = 3: 1 LOQ Signal to Noise = 10: 1 LOD, LOQ and Signal to Noise Ratio (SNR)Analytical Method Development: Analytical Method Development LOQ Quantitation by SNR is accepted Quantitation by Standard deviation of response ( s ) and Slope (S) (10 s/ S) is more adequate as it involves the response of the actual analyte Best to calculate in the region close to y-interceptAnalytical Method Development: Analytical Method Development LOQ and impurities In determination of impurities in APIs and FPPs the LOQ should be determined in the presence of API LOQ should be NMT reporting level LOQ should be given relative to the test concentration of API Specificity of impurity determination should always be demonstrated in the presence of API at API specification levels Spiking of test concentration (API/FPP) with impurities at levels of their specification rangeAnalytical Method Development: Analytical Method Development Spiking API test concentration (normalised) 0.1 mg/ml (100%) Impurity spiking concentrations 0.001 mg/ml (1%) – specification limit 0.0001 mg/ml (0.1%) – limit of quantitation (minimum requirement) API at test concentrations API below test concentrationsAnalytical Method Development: Analytical Method Development Linearity of an analytical procedure is its ability ( within a given range ) to obtain test results which are directly proportional to the concentration (amount) of analyte in the sample If there is a linear relationship test results should be evaluated by appropriate statistical methods Correlation coefficient (r) Y-intercept Slope of regression line Residual sum of squares PLOT OF THE DATAAnalytical Method Development: Analytical Method Development Usual acceptance criteria for a linear calibration curve r > 0.999 ; y-intercept a < 0 to 5% of target concentration RSD (wrt calibration curve) < 1.5-2% r > 0.997 r < 0.997 From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development Range The range of an analytical procedure is the interval between the upper and lower concentration (amounts) of analyte in the sample for which it has been demonstrated that the analytical procedure has a suitable level of precision, accuracy and linearityAnalytical Method Development: Analytical Method Development Range Assay 80 to 120% of test concentration Content uniformity 70 to 130% of test concentration Dissolution Q-20% to 120% Impurities Reporting level – 120% of specification limit (with respect to test concentration of API) Assay & Impurities Reporting level to 120% of assay specificationAnalytical Method Development: Analytical Method Development Linearity is limited to 150%of shelf life specification of impurities Test concentration can be used to determine impurities To determine drug substance (assay) the test concentration must be diluted The range is 0 – ~ 150% of impurity specification From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development Robustness Robustness of an analytical procedure should show the reliability of an analysis with respect to deliberate variations in method parameters The evaluation of robustness should be considered during the development phase If measurements are susceptible to variations in analytical conditions the analytical conditions should be suitably controlled or a precautionary statement should be included in the procedureAnalytical Method Development: Analytical Method Development Influence of buffer pH and buffer concentration in mobile phase on retention times of API and impurities Conclusion: The buffer composition should be maintained in a range of 85 ± 0.5% Missing: Acceptance criterion for maximal deviation of retention time should be defined unless justified Impurity C Impurity B Impurity A API 8.26 7.43 3.86 10.46 As is 8.38 7.51 3.94 10.45 buffer pH 5.9 8.34 7.49 3.94 10.46 buffer pH 6.9 6.66 6.16 3.43 7.84 Buffer conc. 83% 11.18 9.61 4.77 15.26 Buffer conc. 87%Analytical Method Development: Analytical Method Development System suitability testing Based on the concept that equipment, electronics, analytical operations and samples to be analysed constitute an integral system that can be evaluated as such Suitability parameters are established for each analytical procedure individually Depend on the type of analytical procedureAnalytical Method Development: Analytical Method Development Method stability System suitability over time Sample solution stability A solution of stavudine is stable for ~ 2 h, then it starts to degrade to thymine Impurity-spiked sample solution stability A solution containing stavudine spiked with its impurity thymine does not allow to clearly distinguish between degradation and spike A solution containing stavudine of a FPP-stability sample solution does not allow to clearly distinguish between FPP-stability degradation and sample solution degradation Should be analysed immediatelyAnalytical Method Development: Analytical Method Development When to be „surprised“ about validation data: Precision of impurity determination Precision of API determination Method precision of released API (dissolution) % RSD 0.33 – 2.25 System precision % RSD 0.0 Method precision % RSD 0.08 Average peak area % RSD ≤ 2.0 Acceptance criterion % RSD 0.4 Average peak area % RSD ≤ 10.0 Acceptance criterionAnalytical Method Development: Analytical Method Development Specification range (USL-LSL) Process variability (usually ± 2 SD) Analytical variability ( ± 3 s ) ~ NMT 30% of total specification range Analytical variability Process variability Reliability of evaluation of major process variables by analytical procedures depends on analytical variability Impurities LOQ and specification limit (e.g. qualification limits NMT 0.15%) Response factors (LOQ modified by response factor)Analytical Method Development: Analytical Method Development Methods for cleaning validation Method for assay and related substances used in stability studies of API and FPP Specificity (in samples taken from a cleaning assessment ) L inearity of response (from 50% of the cleaning limit to 1 0x this concentration ; R 2 ≥ 0.9900) Precision Repeatability (RSD ≤ 5%) i nter mediate precision [ruggedness (USP)] Reproducibility L imits of detection and quantitation A ccuracy or recovery from rinsate ( ≥ 80%) , swabs ( ≥ 90%) , and process surface ( ≥ 70%) R ange ( lowest level is at least 2x higher than LOQ )Analytical Method Development: Analytical Method Development Summary Analytical procedures play a critical role in pharmaceutical equivalence and risk assessment/management Establishment of product-specific acceptance criteria Assessment of stability of APIs and FPPs Validation of analytical procedures should demonstrate that they are suitable for their intended use Validation of analytical procedures deserves special attention during assessment of dossiers for prequalificationAnalytical Method Development: Analytical Method Development THANK YOU You do not have the permission to view this presentation. In order to view it, please contact the author of the presentation.
Analy_Meth_Dev aSGuest120088 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINT lite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 16 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: November 22, 2011 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Pharmaceutical Development with Focus on Paediatric formulations: Pharmaceutical Development with Focus on Paediatric formulations WHO/FIP Training Workshop Hyatt Regency Hotel Sahar Airport Road Andheri East, Mumbai, India 28 April 2008 – 2 May 2008Analytical Method Development: Analytical Method Development Presented by: Birgit Schmauser, PhD Federal Institute for Drugs and Medical Devices (BfArM) b.schmauser@bfarm.deAnalytical Method Development: Analytical Method Development In this presentation: Standards in developing analytical methods for Originator and multisource generic FPPs Specifications Stability Parallel development of analytical methods for cleaning validationAnalytical Method Development: Analytical Method Development Originator , First-time Generic and Multisource Generic Multisource Generic First-time Generic Originator Pharmacopoeias Information from regulatory agencies (publicly available) & literature data Originator´s specifications API quality standards Pharmacopoeias Information from regulatory agencies (publicly available) & literature data Originator´s specifications FPP quality standards Verify identity, potency, purity of API and FPP by pharmacopoeial methods and in-house methods Derive identity, potency, purity of API and FPP by in house methods Establish identity, potency, purity of API and FPP by in-house methods Analytical methodsAnalytical Method Development: Analytical Method Development HPLC-method to assay potency and purity – risk assessment Multisource Generic First-time Generic Originator Selectively screen /detect any impurity or degradant Establish potency Identify impurities/degradants Verify impurities from Pharmacopoeia Characterise „in-house“ impurities/degradants (Response factors) Derive impurities/degradants from Originator Characterize „in-house“ impurities/degradants Calculate response factors Characterise all impurities/degradants Calculate Response factors (qualification by clinical use) Use pharmacopoeial reference materials Extract (& reproduce ) reference materials Establish reference materials „Implement“ for routine use Adapt /modify to/for routine use Adapt to routine useAnalytical Method Development: Analytical Method Development Interchangeability (IC) of multisource generic FPPs ( Essential similarity with Innovator FPP) Pharmaceutical + Bioequivalence Equivalence IC = PE + BEAnalytical Method Development: Analytical Method Development Pharmaceutical equivalence FPPs meet the same or comparable standards by use of equivalent analytical methods Same API ( chemical and physical equivalence) Same dosage form and route of administration Same strength Comparable labeling Equivalence in pharmaceutical development Equivalence in stability Equivalence in manufacture (WHO-GMP)Analytical Method Development: Analytical Method Development Prequalification requirements Validation of analytical methods is a prerequisite for prequalification of product dossiers Non-compendial APIs and FPPs are tested with methods developed by the manufacturer For compendial APIs and FPPs the „applicability“ of pharmacopoeial methods to particular products must be demonstrated (verification) Analytical methods must be developed and validated according to TRS 823, Annex 5, Validation of analytical procedures used in the examination of pharmaceutical materials ; ICH Q2 (R1) To be used within GLP and GMP environmentsAnalytical Method Development: Analytical Method Development METHODS PHARMACEUTICAL CLINICAL At initial phase of pharmaceutical development To understand the profile of related substances and to study stability To start measuring the impact of key product and manufacturing process parameters on consistent FPP quality To develop a stable and reproducible formulation for the manufacture of bioequivalence, dissolution, stability and pilot-scale validation batches To determine bioavailability in healthy volunteers At advanced phase of pharmaceutical development To be robust, transferable, accurate and precise for specification setting, stability assessment and QC release of prequalified product batches To optimise , scale-up and transfer a stable and controlled manufacturing process for the prequalification product To prove bioequivalence after critical variations to the prequalified dossier Use of analytical methods - genericsAnalytical Method Development: Analytical Method Development Prerequisites for analytical method validation Six “ M ”s Quality of the analytical method M an M achine qualified calibrated robust qualified M ethods suitable characterised documented M ilieu M aterial M anagement Quality Reference standards Tempe- rature Analysts´ support skilled Humidity Vibrations Time Supplies Irradi- ationsAnalytical Method Development: Analytical Method Development Method development life cycle Planning Development and Validation Policy Objectives/Requirements of Method Information Gathering Resource Gathering Method development Initital Method Development Pre-Validation Evaluation Method Optimization Robustness System Suitability Development Plan – Project Customer Evaluation Testing Validation Experiments Method Transfer Experiments Filed Method in Use Periodically Monitoring/Review of Methods in Control Labs From: Analytical Chemistry in a GMP Environment . Edited by J.M. Miller and J.B. Crowther, ISBN 0-471-31431-5, Wiley & Sons Inc.Analytical Method Development: Analytical Method Development Validation should verify the suitability of an analytical method for its intended purpose Validation should be founded on method development performed beforehand that suggest the suitability and robustness of the method Validation may be performed in different ways (individual purpose) according to common standardsSlide 13: Validation protocol Method principle / objective Listing of responsibilities Laboratories involved and their role in the validation Method categorization List of reagents (including test lots) and standards Test procedures to evaluate each validation parameter and proposed acceptance criteria Plan or procedure when acceptance criteria are not met Requirements for the final report The validation process cannot proceed until the protocol and all parties involved approve the acceptance criteriaAnalytical Method Development: Analytical Method Development Innovator versus Generics Generics Innovator - + R & D on API - + Preclinical trials - Method validation summary Clinical trials phase I and II - Method validation completed Clinical trials phase III - Validated methods Post marketing phase IV Validated methods: GMP and GLP Validated methods Entering of Generics; Pharmaceutical development, Comparability with InnovatorAnalytical Method Development: Analytical Method Development Validation Characteristics Assay Impurities Identification limit quantitative + - + - Accuracy + - + - Precision + + + + Specificity - + - - Detection Limit - - + - Quantitation Limit + - + - Linearity + - + - Range + + + + RobustnessAnalytical Method Development: Analytical Method Development Accuracy and precision Accurate & precise Accurate & imprecise Inaccurate & precise Inaccurate & impreciseAnalytical Method Development: Analytical Method Development Precision Expresses the closeness of agreement between a series of measurements obtained from multiple sampling of the same homogenous sample Is usually expressed as the standard deviation (S), variance (S 2 ) or coefficient of variation (RSD) of a series of measurements Precision may be considered at three levels Repeatability (intra-assay precision) Intermediate Precision (variability within a laboratory) Reproducibility (precision between laboratories)Analytical Method Development: Analytical Method Development Normal distribution, probability function [P(x)] and confidence interval [CI] Probability (P) , that measurements from a normal distribution fall within [µ-x n , µ+x n ] for x n = n s is described by the “ erf -function” ( µ = mean) : An interval of ± 3 s covers 99.73% of values Number of times each value occurs P x n 0.6826895 s 0.9544997 2s 0.9973002 3s 0.9999366 4s 0.9999994 5s Values s 2s 3s s 2s 3sAnalytical Method Development: Analytical Method Development Normal distribution, probability function [P(x)] and confidence interval [CI] Probability-P Confidence interval [CI] centered around the mean [µ] in units of sigma [ s ] described by “inverse erf -function”: A CI of 95% includes values ± 1.95 s around the mean x p P 1.28155 s 0.800 1.64485 s 0.900 1.95996 s 0.950 2.57583 s 0.995 3.29053 s 0.999Analytical Method Development: Analytical Method Development Relationship of variability, probability and reliability of data High variability of data (large s ) generate large confidence intervals and thus lower the reliability of the mean Low variability of data (small s) generate small confidence intervals and thus increase the reliability of the meanAnalytical Method Development: Analytical Method Development Repeatability Six replicate sample preparation steps from a homogenously prepared tablet mixture (nominal value of API 150 mg) Assay Peak area Injection 147.10 mg/98.06% 173865 1 148.00 mg/98.66% 174926 2 146.32 mg/97.54% 172933 3 148.08 mg/98.72% 175011 4 151.95 mg/101.30% 179557 5 149.28 mg/99.52% 176425 6 148.45 mg/98.96% 175453 Mean 1.98 mg/1.32% 2329 SD ( s ) 1.32% 1.32% RSD Mean ± 3 SD = Confidence interval of 99.73% 98.96 ± 3x1.32% = 95% - 102.92%Analytical Method Development: Analytical Method Development Intermediate precision Expresses within-laboratories variations (different days, different analysts, different equipment etc.) Peak area analyst 3 Peak area analyst 2 Peak area analyst 1 Injection 177965 175656 173865 1 178556 175878 174926 2 177342 176004 172933 3 178011 176344 175011 4 179466 175332 179557 5 179688 174959 176425 6 178504 175695 175453 Mean 918 495 2329 SD ( s ) 0.51% 0.28% 1.32% RSD Analyst 1: 98.96% ± 3 x 1.32% Analyst 2: 99.12% ± 3 x 0.28 Analyst 3: 100.70% ± 3 x 0.51 Average of 3 analysts ± 3SD : 95% - 102.23% Mean ± 3 SD: (177252 100%)Analytical Method Development: Analytical Method Development Reproducibility Expresses the precision between laboratories Collaborative studies, usually applied to standardisation of methodology Transfer of technology Compendial methodsAnalytical Method Development: Analytical Method Development Accuracy Expresses the closeness of agreement between the value which is accepted either as a conventional true value or an accepted reference value and the value found Sometimes referred to as „ TRUENESS “ true meanAnalytical Method Development: Analytical Method Development To find out whether a method is accurate: Drug substance (assay) Application of the method to an analyte of known purity (e.g. reference substance) Comparison of the results of one method with those of a second well-characterised method (accuracy known) Drug product (assay) Application of the method to synthetic mixtures of the drug product component to which known quantities of the analyte have been added Drug product may exceptionally be used as matrix Drug substance/Drug product (Impurities) Application of the method to samples spiked with known amounts of impuritiesAnalytical Method Development: Analytical Method Development Accuracy : Application of the method to synthetic mixtures of the drug product components to which known quantities of the analyte have been added Recovery reduced by ~10 – 15% From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development When to expect Accuracy problems Insufficient selectivity of the method Impurity peaks are not resolved and account for assay value Recovery is < 100% Irreversible adsorption of analyte to surfaces of the system Incorrect assay value of a reference standard Due to decomposition of reference standard Incorrect assay value due to change in matrix Analytical laboratory still uses the preceding matrix as standardAnalytical Method Development: Analytical Method Development Specificity Is the ability to assess unequivocally the analyte in the presence of components which may be expected to be present (impurities, degradants, matrix…) Identity testing To ensure the identity of an analyte Purity testing To ensure accurate statement on the content of impurities of an analyte Assay To allow an accurate statement on the content of an analyte in a sampleAnalytical Method Development: Analytical Method Development Specificity: Overlay chromatogram of an impurity solution with a sample solution From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development Specificity and stability Stress stability testing to ensure the stability indicating potential of an analytical method Apply diverse stress factors to the API Apply diverse stress factors to the FPP Stress conditions: e.g. Supplement 2 of Generic Guideline; TRS 929, Annex 5 Assure that the API can be assessed specifically in the presence of known and unknown (generated by stress) impurities Assure that known impurities/degradants can be specifically assessed in the presence of further degradants By peak purity assessment and (overlay of) chromatogramsAnalytical Method Development: Analytical Method Development Stress stability studies versus forced degradation studies Stress stability (5 – 15% decomposition) Forced degradation Stress parameter pH ± 2 (2 weeks) 0.2 ml 1N HCl / 5 ml API-solution / 3h, 6h , 12h, 24h…7d (RT & 60°C) Acid pH ± 10 (2 weeks) 0.2 ml 1N NaOH / 5 ml API-solution / 3h, 6h , 12h, 24h…7d (RT & 60°C) Base 1 g/ml oxygen bubbled through (8 hours) 0.1 – 2% H 2 O 2 (24 hours) 0.2 ml 5% or 35% H 2 O 2 / 5 ml API-solution (RT, to 7d & 60°C, 3h ) H 2 O 2 / Oxygen - 60°C / 5 ml solution ( 3h, 6h …7d) Heat 60°C (4 weeks) 105° C / solid API ( 1d and 7d) Heat 365 nm or white fluorescent light / solid API ( 1d and 7d) UV or Light 50°C / 80% RH (4 weeks) - HumidityAnalytical Method Development: Analytical Method Development Limit of Detection (LOD, DL) The LOD of an analytical procedure is the lowest amount of analyte in sample which can be detected but not necessarily quantitated as an exact value Determination is usually based on Signal to noise ratio (~3:1) ( baseline noise ) or Standard deviation of response ( s ) and Slope (S) 3.3 s /SAnalytical Method Development: Analytical Method Development Limit of Quantitation (LOQ, QL) The LOQ is the lowest amount of analyte in a sample which can be quantitatively determined with suitable precision and accuracy The quantitation limit is used particularly for the determination of impurities and/or degradation products Determination is usually based on Signal to noise ratio (~10:1) ( baseline noise ) or Standard deviation of response ( s ) and Slope (S) 10 s/ SAnalytical Method Development: Analytical Method Development Noise LOD Signal to Noise = 3: 1 LOQ Signal to Noise = 10: 1 LOD, LOQ and Signal to Noise Ratio (SNR)Analytical Method Development: Analytical Method Development LOQ Quantitation by SNR is accepted Quantitation by Standard deviation of response ( s ) and Slope (S) (10 s/ S) is more adequate as it involves the response of the actual analyte Best to calculate in the region close to y-interceptAnalytical Method Development: Analytical Method Development LOQ and impurities In determination of impurities in APIs and FPPs the LOQ should be determined in the presence of API LOQ should be NMT reporting level LOQ should be given relative to the test concentration of API Specificity of impurity determination should always be demonstrated in the presence of API at API specification levels Spiking of test concentration (API/FPP) with impurities at levels of their specification rangeAnalytical Method Development: Analytical Method Development Spiking API test concentration (normalised) 0.1 mg/ml (100%) Impurity spiking concentrations 0.001 mg/ml (1%) – specification limit 0.0001 mg/ml (0.1%) – limit of quantitation (minimum requirement) API at test concentrations API below test concentrationsAnalytical Method Development: Analytical Method Development Linearity of an analytical procedure is its ability ( within a given range ) to obtain test results which are directly proportional to the concentration (amount) of analyte in the sample If there is a linear relationship test results should be evaluated by appropriate statistical methods Correlation coefficient (r) Y-intercept Slope of regression line Residual sum of squares PLOT OF THE DATAAnalytical Method Development: Analytical Method Development Usual acceptance criteria for a linear calibration curve r > 0.999 ; y-intercept a < 0 to 5% of target concentration RSD (wrt calibration curve) < 1.5-2% r > 0.997 r < 0.997 From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development Range The range of an analytical procedure is the interval between the upper and lower concentration (amounts) of analyte in the sample for which it has been demonstrated that the analytical procedure has a suitable level of precision, accuracy and linearityAnalytical Method Development: Analytical Method Development Range Assay 80 to 120% of test concentration Content uniformity 70 to 130% of test concentration Dissolution Q-20% to 120% Impurities Reporting level – 120% of specification limit (with respect to test concentration of API) Assay & Impurities Reporting level to 120% of assay specificationAnalytical Method Development: Analytical Method Development Linearity is limited to 150%of shelf life specification of impurities Test concentration can be used to determine impurities To determine drug substance (assay) the test concentration must be diluted The range is 0 – ~ 150% of impurity specification From : Analytical Method Validation and Instrument Performance Verification , Edited by Chung Chow Chan,Herman Lam, Y.C. Lee and Xue-Ming Zhang, ISBN 0-471-25953-5, Wiley & SonsAnalytical Method Development: Analytical Method Development Robustness Robustness of an analytical procedure should show the reliability of an analysis with respect to deliberate variations in method parameters The evaluation of robustness should be considered during the development phase If measurements are susceptible to variations in analytical conditions the analytical conditions should be suitably controlled or a precautionary statement should be included in the procedureAnalytical Method Development: Analytical Method Development Influence of buffer pH and buffer concentration in mobile phase on retention times of API and impurities Conclusion: The buffer composition should be maintained in a range of 85 ± 0.5% Missing: Acceptance criterion for maximal deviation of retention time should be defined unless justified Impurity C Impurity B Impurity A API 8.26 7.43 3.86 10.46 As is 8.38 7.51 3.94 10.45 buffer pH 5.9 8.34 7.49 3.94 10.46 buffer pH 6.9 6.66 6.16 3.43 7.84 Buffer conc. 83% 11.18 9.61 4.77 15.26 Buffer conc. 87%Analytical Method Development: Analytical Method Development System suitability testing Based on the concept that equipment, electronics, analytical operations and samples to be analysed constitute an integral system that can be evaluated as such Suitability parameters are established for each analytical procedure individually Depend on the type of analytical procedureAnalytical Method Development: Analytical Method Development Method stability System suitability over time Sample solution stability A solution of stavudine is stable for ~ 2 h, then it starts to degrade to thymine Impurity-spiked sample solution stability A solution containing stavudine spiked with its impurity thymine does not allow to clearly distinguish between degradation and spike A solution containing stavudine of a FPP-stability sample solution does not allow to clearly distinguish between FPP-stability degradation and sample solution degradation Should be analysed immediatelyAnalytical Method Development: Analytical Method Development When to be „surprised“ about validation data: Precision of impurity determination Precision of API determination Method precision of released API (dissolution) % RSD 0.33 – 2.25 System precision % RSD 0.0 Method precision % RSD 0.08 Average peak area % RSD ≤ 2.0 Acceptance criterion % RSD 0.4 Average peak area % RSD ≤ 10.0 Acceptance criterionAnalytical Method Development: Analytical Method Development Specification range (USL-LSL) Process variability (usually ± 2 SD) Analytical variability ( ± 3 s ) ~ NMT 30% of total specification range Analytical variability Process variability Reliability of evaluation of major process variables by analytical procedures depends on analytical variability Impurities LOQ and specification limit (e.g. qualification limits NMT 0.15%) Response factors (LOQ modified by response factor)Analytical Method Development: Analytical Method Development Methods for cleaning validation Method for assay and related substances used in stability studies of API and FPP Specificity (in samples taken from a cleaning assessment ) L inearity of response (from 50% of the cleaning limit to 1 0x this concentration ; R 2 ≥ 0.9900) Precision Repeatability (RSD ≤ 5%) i nter mediate precision [ruggedness (USP)] Reproducibility L imits of detection and quantitation A ccuracy or recovery from rinsate ( ≥ 80%) , swabs ( ≥ 90%) , and process surface ( ≥ 70%) R ange ( lowest level is at least 2x higher than LOQ )Analytical Method Development: Analytical Method Development Summary Analytical procedures play a critical role in pharmaceutical equivalence and risk assessment/management Establishment of product-specific acceptance criteria Assessment of stability of APIs and FPPs Validation of analytical procedures should demonstrate that they are suitable for their intended use Validation of analytical procedures deserves special attention during assessment of dossiers for prequalificationAnalytical Method Development: Analytical Method Development THANK YOU