LArPerf16mar05

Uploaded from authorPOINTLite
Views:
 
Category: Entertainment
     
 

Presentation Description

No description available.

Comments

Presentation Transcript

Sliding window cluster corrections for 10.0.1: 

Sliding window cluster corrections for 10.0.1 S.Snyder (BNL),S.Paganis (Wisconsin) (with the help of many LAr people) LAr Performance Meeting CERN, 16-Mar-05

Reminders: 

Reminders 10.0.0: We have new cluster corrections but old longitudinal weights 10.0.1: We want to add new cluster dependent longitudinal weights Linearity is good to 2ppm from 10GeV to 1TeV Resolution improves Presently: Weights are ONLY eta dependent and Energy independent

Confusion: 

Confusion We have samples of DC2 electrons (8.0.x) We have e samples for 9.0.x Final Layout We have e samples for 9.0.4 Rome Layout One must be careful with turn-on of charge collection effects and change in the Sampling Fractions in the EndCap. Bottomline: 9.0.4 electrons have consistent EndCap simulation while 9.0.x with x<4 don’t. DC2 and 9.0.x electrons have consistent Barrel simulation

9.0.x Final Layout Electrons: h=0.3, new corrections + new weights, 3x7: 

10 GeV Mean: 0.0021 Sigma: 4.1% TDR: 2.74% 20 GeV Mean: 0.0008 Sigma: 2.3% TDR: 1.974% 50 GeV Mean: 0.0001 Sigma: 1.4% TDR: 1.31% 100 GeV Mean: 0.0001 Sigma: 0.96% TDR: 0.99% 9.0.x Final Layout Electrons: h=0.3, new corrections + new weights, 3x7

Reminder: TDR result for 3x7: 

Reminder: TDR result for 3x7

Slide6: 

DC2 electrons with new corrections + new weights running 10.0.0 (K.Benslama) 500 GeV 5x5 DC2 electrons 1 TeV 5x5 DC2 electrons

DC2 electrons with new corrections + new weights running 10.0.0 (K.Benslama) : 

DC2 electrons with new corrections + new weights running 10.0.0 (K.Benslama) Barrel Only: integrated over eta, 5x5 Improved Linearity Improved Resolution

Rome 904 Electrons with new corrections and new weights: 100GeV and 200GeV: 

Rome 904 Electrons with new corrections and new weights: 100GeV and 200GeV 100 GeV h=0.3 5x5 Mean: 0.004 Sigma: 1.0% 200 GeV h=0.3 5x5 Mean: 0.0036 Sigma: 0.08% The Rome electrons are slightly overcorrected +0.4% Rome Electrons produced by Neng Xu and Luis Flores (Wisconsin)

Rome 904 Electrons with new corrections and new weights: 5GeV electrons at h=0.3: 

Rome 904 Electrons with new corrections and new weights: 5GeV electrons at h=0.3 5 GeV h=0.3 5x5 Mean: 0.015 Sigma: 8% Reasonable results all the way down to 5GeV! We rediscover the DC1 result that weights work from a few GeV to the TeV scale.

EndCap: Rome 904 Electrons with new corrections and new weights + rec10.0.0 (Karina Loureiro): 

EndCap: Rome 904 Electrons with new corrections and new weights + rec10.0.0 (Karina Loureiro) Rome Electrons produced by Neng Xu and Luis Flores (Wisconsin) 100 GeV h=2.0375 5x5 (no Presampler)

Summary: 

Summary Barrel: We have new Long. Weights which give ppm linearity from ~10GeV to TeV and improved resolution. EndCap: We have new L.Weights which also seem to be performing fine, although we have done less validation than in the barrel. Implementation in 10.0.1 ? (for 5x5, 3x5 and 3x7 sizes)