logging in or signing up Product Review Marco1 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINTLite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 144 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: January 09, 2008 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Slide1: Industrial on-line pH measurement & control The Easy Way!Slide2: Universal Analyzers Founded 1985 Ted Barben, President Jim Walden, CFO Bob Bertik, Sales Manager Stack gas sample conditioners Gas chillers PLC sample system controlsSlide3: 1963 – Invented “double junction” sensor, founding engineer Uni-Loc Corp. 1975 – Invented wood-cored pH sensor, founding engineer TBI 1990 – Founded Universal Analyzers 2001 – Invented Axial Ion Path pH sensor, founder B.A.T.Slide4: Barben Analyzer Technology, LLC Founded 2001 Don Peterson - Sales & Marketing Harvey Mitchell - Operations pH/ORP/Conductivity sensors Transmitters / Analyzers Process control Installation accessories Integrated systemsSlide5: Product ReviewSlide6: The # 1 goal of a good industrial sensor is to…Slide7: Survive what the customer does to it.Slide8: The # 2 goal is to be easily serviceableSlide9: The # 3 goal is to be reliableSlide10: The # 4 goal is to be repeatableSlide11: pH / ORP Sensors Features & BenefitsSlide12: Axial Ion Path Reference CellSlide14: Features & Benefits Long tortuous path Resists poison ingressSlide15: Features & Benefits 5 filtration stages Resists poison ingressSlide16: Features & Benefits Non-fouling ion paths No internal pluggingSlide17: Features & Benefits Large quantity of KCl Long life in low and high pH applicationsSlide18: Features & Benefits Complete filling Tolerance of high pressures & temperaturesSlide19: Features & Benefits Pre-soaked blocks No crushing of glass electrodeSlide20: Features & Benefits Pre-soaked blocks No internal leak pathsSlide21: Features & Benefits Nose baffle seals Resists dehydration when exposed to airSlide22: Features & Benefits Massive Reference Electrode Wire Resists precipitation & oxidationSlide23: Features & Benefits Teflon Junction Resists coating, controls KCl flowSlide24: Features & Benefits Electrodes Wide range of choicesSlide25: Features & Benefits Ruggedized “R” Glass Resists breakage Tolerance to caustics Hi-temp capabilitySlide26: Features & Benefits Low temp “E” glass Ruggedized Very fast in low tempsSlide27: Features & Benefits Platinum “PX” Billet Unbreakable Easy to clean Not platedSlide28: Features & Benefits Flat “FG” Glass “J” Glass formula Good for pulp streamsSlide29: Features & Benefits Flouride Resistant “FR” Glass Low-temp flouride toleranceSlide30: Features & Benefits Tip Designs # 1 choice Hemi-glass with Recessed tipSlide31: Features & BenefitsSlide32: Features & Benefits Tip Designs # 2 choice Hemi-glass with Dual-notch tip Slide33: Features & BenefitsSlide34: Features & Benefits Tip Designs # 3 choice Flat glass with flush tip – pulp lines Slide35: Features & BenefitsSlide36: Features & Benefits Tip Designs Auto-clean systems may require specific tip Slide37: Features & Benefits Compatible with Most Transmitters Best Choice Stratos & ProtosSlide38: Features & Benefits Compatible with Most Transmitters Rosemount, ABB, Yokogawa, FoxboroSlide39: Features & Benefits Compatible with Most Transmitters GLI, Eutech, ECD, Hach, E&HSlide40: Features & Benefits Cabling Options Best choice Integral TPE cableSlide41: Features & Benefits Cabling Options TOP 68 Quick-DisconnectSlide42: pH Sensors 546 / 556 Threaded In-Line & Submersible ¾” MNPT top and bottom All body materials All optionsSlide43: 547 / 557 Replaceable Sensor Cartridge Ball-Valve Insertion Threaded In-Line Submersible Hi-Purity Hi-Pressure pH SensorsSlide44: 551 / 561 Quick Change in-line & Submersible 1” MNPT Nut-loc adapter ¾” MNPT on top Safer than twist loc Hi-pressure version pH SensorsSlide45: Available in all 3 body styles: pH ORP 4-Electrode Conductivity DO pH SensorsSlide46: Hot New Products: BAT-1 & 2 General Purpose Sensors 546 Threaded In-line or Submersible AIP Reference Water/Wastewater market $ 175 with discount for multiples pH SensorsSlide47: Hot New Products: Dissolved Oxygen Galvanic Membrane style Replaceable membrane cartridge Economical complete packages Auto-clean options DO SystemsSlide48: Hot New Products: Turbidity & Suspended Solids Immersion & Hygenic sensors Controller and Transmitter Replaces competitor sensors Turbidity & Suspended SolidsSlide49: Hot New Products: Hi-Pressure Insertion System Uses 546/556 sensor Up to 300 psig Easier insertion pressure in lo-pressure applications Hi-Pressure InsertionSlide50: Hi-Pressure Insertion System 300 PSISlide51: Hot New Products: B46 4 – Electrode Conductivity Ultra-stable Self-compensating for scale and corrosion Wide conductivity range Available in all BAT body styles 4-Electrode ConductivitySlide52: 4-Electrode ConductivitySlide53: Hot Old Products: B37 – B36 Jet Cleaners Clean both glass and reference Use when client must clean 2+ times/week Can use air, water, special cleaning fluids Submerged or in-line operation Jet CleanersSlide54: Jet CleanersSlide55: Hot Old Products: B38 Mechanical Scrubbers Cleans glass electrode only Good for oily / fatty waters Can use air or water Submerged operation – optional pot Mechanical ScrubberSlide56: Mechanical ScrubberSlide57: Hot Old Products: All Scrubbers and Cleaners Sales opportunity for B41 Fluid Dist Unit Check minimum pressure available Confirm access hole is big enough Locally supplied stand-pipe Scrubbers & Cleaners You do not have the permission to view this presentation. In order to view it, please contact the author of the presentation.
Product Review Marco1 Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINTLite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 144 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: January 09, 2008 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript Slide1: Industrial on-line pH measurement & control The Easy Way!Slide2: Universal Analyzers Founded 1985 Ted Barben, President Jim Walden, CFO Bob Bertik, Sales Manager Stack gas sample conditioners Gas chillers PLC sample system controlsSlide3: 1963 – Invented “double junction” sensor, founding engineer Uni-Loc Corp. 1975 – Invented wood-cored pH sensor, founding engineer TBI 1990 – Founded Universal Analyzers 2001 – Invented Axial Ion Path pH sensor, founder B.A.T.Slide4: Barben Analyzer Technology, LLC Founded 2001 Don Peterson - Sales & Marketing Harvey Mitchell - Operations pH/ORP/Conductivity sensors Transmitters / Analyzers Process control Installation accessories Integrated systemsSlide5: Product ReviewSlide6: The # 1 goal of a good industrial sensor is to…Slide7: Survive what the customer does to it.Slide8: The # 2 goal is to be easily serviceableSlide9: The # 3 goal is to be reliableSlide10: The # 4 goal is to be repeatableSlide11: pH / ORP Sensors Features & BenefitsSlide12: Axial Ion Path Reference CellSlide14: Features & Benefits Long tortuous path Resists poison ingressSlide15: Features & Benefits 5 filtration stages Resists poison ingressSlide16: Features & Benefits Non-fouling ion paths No internal pluggingSlide17: Features & Benefits Large quantity of KCl Long life in low and high pH applicationsSlide18: Features & Benefits Complete filling Tolerance of high pressures & temperaturesSlide19: Features & Benefits Pre-soaked blocks No crushing of glass electrodeSlide20: Features & Benefits Pre-soaked blocks No internal leak pathsSlide21: Features & Benefits Nose baffle seals Resists dehydration when exposed to airSlide22: Features & Benefits Massive Reference Electrode Wire Resists precipitation & oxidationSlide23: Features & Benefits Teflon Junction Resists coating, controls KCl flowSlide24: Features & Benefits Electrodes Wide range of choicesSlide25: Features & Benefits Ruggedized “R” Glass Resists breakage Tolerance to caustics Hi-temp capabilitySlide26: Features & Benefits Low temp “E” glass Ruggedized Very fast in low tempsSlide27: Features & Benefits Platinum “PX” Billet Unbreakable Easy to clean Not platedSlide28: Features & Benefits Flat “FG” Glass “J” Glass formula Good for pulp streamsSlide29: Features & Benefits Flouride Resistant “FR” Glass Low-temp flouride toleranceSlide30: Features & Benefits Tip Designs # 1 choice Hemi-glass with Recessed tipSlide31: Features & BenefitsSlide32: Features & Benefits Tip Designs # 2 choice Hemi-glass with Dual-notch tip Slide33: Features & BenefitsSlide34: Features & Benefits Tip Designs # 3 choice Flat glass with flush tip – pulp lines Slide35: Features & BenefitsSlide36: Features & Benefits Tip Designs Auto-clean systems may require specific tip Slide37: Features & Benefits Compatible with Most Transmitters Best Choice Stratos & ProtosSlide38: Features & Benefits Compatible with Most Transmitters Rosemount, ABB, Yokogawa, FoxboroSlide39: Features & Benefits Compatible with Most Transmitters GLI, Eutech, ECD, Hach, E&HSlide40: Features & Benefits Cabling Options Best choice Integral TPE cableSlide41: Features & Benefits Cabling Options TOP 68 Quick-DisconnectSlide42: pH Sensors 546 / 556 Threaded In-Line & Submersible ¾” MNPT top and bottom All body materials All optionsSlide43: 547 / 557 Replaceable Sensor Cartridge Ball-Valve Insertion Threaded In-Line Submersible Hi-Purity Hi-Pressure pH SensorsSlide44: 551 / 561 Quick Change in-line & Submersible 1” MNPT Nut-loc adapter ¾” MNPT on top Safer than twist loc Hi-pressure version pH SensorsSlide45: Available in all 3 body styles: pH ORP 4-Electrode Conductivity DO pH SensorsSlide46: Hot New Products: BAT-1 & 2 General Purpose Sensors 546 Threaded In-line or Submersible AIP Reference Water/Wastewater market $ 175 with discount for multiples pH SensorsSlide47: Hot New Products: Dissolved Oxygen Galvanic Membrane style Replaceable membrane cartridge Economical complete packages Auto-clean options DO SystemsSlide48: Hot New Products: Turbidity & Suspended Solids Immersion & Hygenic sensors Controller and Transmitter Replaces competitor sensors Turbidity & Suspended SolidsSlide49: Hot New Products: Hi-Pressure Insertion System Uses 546/556 sensor Up to 300 psig Easier insertion pressure in lo-pressure applications Hi-Pressure InsertionSlide50: Hi-Pressure Insertion System 300 PSISlide51: Hot New Products: B46 4 – Electrode Conductivity Ultra-stable Self-compensating for scale and corrosion Wide conductivity range Available in all BAT body styles 4-Electrode ConductivitySlide52: 4-Electrode ConductivitySlide53: Hot Old Products: B37 – B36 Jet Cleaners Clean both glass and reference Use when client must clean 2+ times/week Can use air, water, special cleaning fluids Submerged or in-line operation Jet CleanersSlide54: Jet CleanersSlide55: Hot Old Products: B38 Mechanical Scrubbers Cleans glass electrode only Good for oily / fatty waters Can use air or water Submerged operation – optional pot Mechanical ScrubberSlide56: Mechanical ScrubberSlide57: Hot Old Products: All Scrubbers and Cleaners Sales opportunity for B41 Fluid Dist Unit Check minimum pressure available Confirm access hole is big enough Locally supplied stand-pipe Scrubbers & Cleaners