[PDF] INTRODUCTION TO Dell EMC PowerEdge (DES-4121) Exam

Views:
 
Category: Education
     
 

Presentation Description

Get complete detail on DES-4121 exam guide to crack Dell EMC PowerEdge Specialist for Implementation Engineer. You can collect all information on DES-4121 tutorial, practice test, books, study material, exam questions, and syllabus. Firm your knowledge on Dell EMC PowerEdge Specialist for Implementation Engineer and get ready to crack DES-4121 certification. Explore all information on DES-4121 exam with number of questions, passing percentage and time duration to complete test.

Comments

Presentation Transcript

slide 1:

INTRODUCTION TO DELL EMC CERTIFIED SPECIALIST - IMPLEMENTATION ENGINEER - POWEREDGE EXAM DES-4121 Practice Test and Certification Guide EDUSUM.COM Get complete detail on DES-4121 exam guide to crack Dell EMC PowerEdge Specialist for Implementation Engineer. You can collect all information on DES-4121 tutorial practice test books study material exam questions and syllabus. Firm your knowledge on Dell EMC PowerEdge Specialist for Implementation Engineer and get ready to crack DES-4121 certification. Explore all information on DES-4121 exam with number of questions passing percentage and time duration to complete test.

slide 2:

WWW.EDUSUM.COM PDF DES-4121: Dell EMC PowerEdge Specialist for Implementation Engineer 1 Introduction to Dell EMC Certified Specialist - Implementation Engineer - PowerEdge Exam The Dell EMC DES-4121 Exam is challenging and thorough preparation is essential for success. This exam study guide is designed to help you prepare for the PowerEdge Implementation Engineer certification exam. It contains a detailed list of the topics covered on the Professional exam as well as a detailed list of preparation resources. These study guide for the Dell EMC Specialist - Implementation Engineer - PowerEdge will help guide you through the study process for your certification. DES-4121 Dell EMC Specialist - Implementation Engineer - PowerEdge Exam Summary ● Exam Name: Dell EMC Specialist - Implementation Engineer - PowerEdge ● Exam Code: DES-4121

slide 3:

WWW.EDUSUM.COM PDF DES-4121: Dell EMC PowerEdge Specialist for Implementation Engineer 2 ● Exam Price: 200 USD ● Duration: 90 mins ● Number of Questions: 60 ● Passing Score: 63 ● Schedule Exam: Pearson VUE ● Sample Questions: Dell EMC PowerEdge Implementation Engineer Sample Questions ● Recommended Practice: Dell EMC DES-4121 Certification Practice Exam Exam Syllabus: DES-4121 Dell EMC Certified Specialist - Implementation Engineer - PowerEdge 1. Install 29 - Interpret System Hardware Configuration - Install Server hardware Update firmware - Perform initial server/hardware setup 2. Configure 33 - Configure Server Storage System Setup iDRAC LifeCycle Controller 3. Maintain 16 - Perform server firmware updates - Install and configure support and management tools 4. Troubleshoot 22 - Troubleshoot hardware and Configuration issues Dell EMC DES-4121 Certification Sample Questions and Answers To make you familiar with Dell EMC Specialist - Implementation Engineer - PowerEdge DES-4121 certification exam structure we have prepared this sample question set. We suggest you to try our Sample Questions for PowerEdge Implementation Engineer DES-4121 Certification to test your understanding of Dell EMC DES- 4121process with real Dell EMC certification exam environment.

slide 4:

WWW.EDUSUM.COM PDF DES-4121: Dell EMC PowerEdge Specialist for Implementation Engineer 3 DES-4121 Dell EMC Specialist - Implementation Engineer - PowerEdge Sample Questions:- 01. A server is configured in a 1+1 power configuration with both PSUs connected to a single PDU. Which redundancy options does this configuration supply a PSU redundancy only b PSU redundancy and PDU redundancy c No redundancy unless each PSU is connected to a separate PDU d PSU redundancy and Grid redundancy 02. A technician needs to configure a server to allow the OS to manipulate processor frequencies for higher power efficiency. Which setting can they enable to achieve this a Logical Processing b Performance per Watt DAPC c Adjacent Cache Line Prefetch d Performance per Watt OS 03. A technician is replacing a fan on a mission critical PowerEdge R740 server that needs to stay operational. The server has no LCD. How can the technician determine which fan needs to be replaced a Run embedded diagnostics to locate the failing fan b Access the Lifecycle Controller navigate to the System Cooling section to locate the failing fan number c Remove the chassis cover and observe a fan with an amber LED d Use the iDRAC GUI to locate failing fan number 04. How can a system administrator compare the currently installed hardware to the original system configuration a Pull a SupportAssist Collection Comparison Report b Restore the original System Profile c View Factory Shipped Inventory d Export a Tech Support Report 05. A technician receives a repurposed PowerEdge server. After racking and cabling the server they attempt to log into the iDRAC but cannot do so. The default login account has been disabled. What method can be used to enable the default login account a Run the racadm racreset command from the host OS b Boot to F2 and select iDRAC Settings Reset iDRAC configurations to defaults all c Hold down the i button for 16 seconds d SSH into the iDRAC and run the racadm racreset command

slide 5:

WWW.EDUSUM.COM PDF DES-4121: Dell EMC PowerEdge Specialist for Implementation Engineer 4 06. A new Dell customer is ordering servers that have very specific firmware dependencies. Any replaced parts of the same type must match the replaced original part identically. The procedure must be as simple as possible with minimal risk. What action should a technician take to accomplish this goal a Confirm that a valid iDRAC enterprise license exists b Enable the Match Firmware of Replaced Part setting in the system BIOS c Configure servers to access the remote firmware repository d Install and configure a repository manager 07. A technician is deploying a server. What should they do once the server is fully configured and deployed a Switch on write-protect for the vFlash SD card b Back up the server profile and reset the iDRAC to Default Settings c Back up the server profile and configure the Parts Replacement feature d Change the iDRAC secure password based on the users’ company policies 08. A technician installs a NIC on a single CPU server. However the NIC is not detected when they power on the server. What should the technician verify to make sure that the NIC is detected correctly a NIC driver is up to date b System Setup is set to BIOS boot mode c NIC is installed in an expansion slot managed by the single CPU d Network cable is plugged into the newly installed NIC 09. A server is to be configured with a six disk RAID 10 array using 3 TB drives. What is the expected available array size for this configuration a 4 TB b 9 TB c 6 TB d 12 TB 10. A technician wants to configure the iDRAC on a new server using the iDRAC Quick Sync 2 feature. What is required to use this feature a OpenManage Mobile App installed on an Android or iOS device b OpenManage Mobile App installed on a laptop c Quick Sync enabled bezel d iDRAC Enterprise license Answers:- Answer 1 :- a Answer 2 :- d Answer 3 :- d Answer 4 :- a

slide 6:

WWW.EDUSUM.COM PDF DES-4121: Dell EMC PowerEdge Specialist for Implementation Engineer 5 Answer 5 :- b Answer 6 :- a Answer 7 :- d Answer 8 :- c Answer 9 :- b Answer 10:- a

authorStream Live Help