slide 1:

GE Measurement Control The PRECISE DPS2000 Series digital pressure transmitter is an ultra high accuracy digital pressure and temperature sensor designed for high pressure measurement in critical applications in harsh environments where accuracy and stability of the data are key to system performance. Features and Benefi ts • Pressure ranges up to 1480 bar/21000 psi • Total accuracy ±0.01 FS • Long-term stability ±0.01 FS/year • Resolution 2 ppm • Shock and vibration resistant • High overpressure capability • Low current consumption • RS-232 and RS-485 communication Applications Areas Oceanographic Applications: • Vertical depth measurement • AUVs and Submarines • ROVs towed arrays bathymetry • Tsunami detection • Dynamic subsea positioning High Pressure Calibration: • Rugged high pressure transfer standard • Laboratory reference • Portable calibration equipment • Pressure controllers • Leak detection The PRECISE DPS2000 Series Digital Pressure Transmitter

slide 2:

Advanced Sensing Technology At the core of the PRECISE sensor is PRESENS’ patented tubular sensing element well proven in subsea oil and gas applications for many years. Our piezoresistivesensors are distinguished for their reliability robustness long-term stability and high fi eld accuracy. This is due to the unique features of the sensing element: Silicon Si single crystal structure: • Minimizes errors due to thermal and mechanical hysteresis • Prevents long-term drift due to ”creep” Tubular design: • Mechanical decoupling of sensing area eliminates error due to mounting stress Operation in compressive stress: • Extreme tolerance to over-pressure and pressure spikes Piezoresistive resistor bridge: • Extremely stable • Pressure and temperature measured simultaneously Unique Pressure Module Design • A thick isolation diaphragm improves protection against harsh environments • A reduced oil volume decreases thermal errors • A reduced oil volume improves protection against damage caused by transient step changes in pressure Dimensional Drawing all dimensions in mm Protective diaphragm Hydraulic oil Sensing element Die attach Glass feed throughs Sensor housing Gold plated pins

slide 3:

PRECISE Specifi cations Pressure Measurement Pressure Ranges Min. range: 0 to 50 bar Max. range: 0 to 1480 bar Pressure Reference Absolute Overpressure 1.5 x FS ranges listed above equals the maximum pressure that can be applied to a transducer without damage or change in performance beyond the specifi ed tolerance. Pressure Containment Burst Pressure 2 x FS ranges listed above Pressure Scales bar psi mH 2 O MPa dbar Temperature Measurement Temperature range: ±0.6°C over the compensated temperature range Pressure Performance Accuracy For each specifi cation better than A1 ±0.04 FS A2 ±0.02 FS A3 ±0.01 FS Defi ned as pressure hysteresis temperature hysteresis temperature effects repeatability non-linearity zero offset and uncertainty of calibration equipment over the compensated temperature range. Compensated Temperature Range: -5 to 35°C 23 to 95°F Long Term Stability drift: 0.01 FS/year max. at reference conditions Resolution 2 ppm FS Acceleration positional Sensitivity Less than 1 mbar/g Shock IEC 60068-2-27: 30 g 11 ms half-sine 3x4 bidirectional shocks Operating within requirements Vibration IEC 60068-2-6: Sinusoidal 5-1000 Hz 20 g 10 ct/min IEC 60068-2-64: Random 20-2000 Hz 6 grms 2 hours Operating within requirements Electrical Power Supply Voltage 8.5-30 Vdc Current Consumption Typ 4.8 mA 24 V receive mode Pulse Power Excitation Switch on to sample time in less than 1 second Output Signal and Protocol RS-232 and RS-485 programmable pressure signal output Modbus Remote Terminal Unit RTU Programmable Lowpass Filter User defi nable down to 30 mHz EMC/RFI Certifi cation IEC 61326 basic immunity test requirements Electrical Insulation Greater than 1 G Ω at 100 Vdc Physical Pressure Connection Autoclave F250C 9/16” G 1/4” Male Pressure Equipment Directive PED 97/23/EC - SEP Operating Temperature Range -40 to 85°C -40 to 185°F Storage Temperature Range -50 to 100°C -58 to 212°F Material Wetted Parts: Inconel 625 Non Wetted Parts: Inconel 625 or AISI316 Electrical Connection 1 metre shielded cable CE Approval Designed for electromagnetic compatibility Calibration Certifi cate Each unit is supplied with a calibration certifi cate stating conformity to pressure performance specifi cations across calibrated pressure and temperature envelope. The specifi cations are traceable to international standards.

slide 4:

920-667A © 2016 General Electric Company. All Rights Reserved. Specifi cations are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies which are not affi liated with GE. www.gemeasurement.com 1. Specify Part String Model DPS Digital Pressure Transmitter Series 2 High Precision Build 0 Non-Hyperbaric Electrical Connection 2 1 m Polyurethane Screened Cable Depth IP68 Output B RS-232/RS-485 Modbus Compensated Temperature Range TA -5 to 35 °C Accuracy A1 Industrial 0.04 A2 Improved 0.02 200 bar and above A3 Premium 0.01 400 bar and above Calibration CC Full Thermal Calibration Hazardous area approval H0 None Pressure Connection P1 G1/4 Male w/nipple pressure ranges to 700 bar P2 9/16-18UNF F250C Female 2. Specify Pressure Range 0 to 50 to 1480 bar 3. Specify Pressure Units bar psi mH 2 0 MPa dbar Examples: DPS202B-TA-A3-CC-H0-P1 0 to 450 bar DPS202B-TA-A2-CC-H0-P2 0 to 30 MPa PRECISE Part Number