MicroE Systems Mercury I Product Presentation

Views:
 
     
 

Presentation Description

MicroE Systems Mercury I Product Presentation

Comments

Presentation Transcript

PowerPoint Presentation: 

Mercury Overview ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com

PowerPoint Presentation: 

Mercury Family Analog Quadrature in the head Programmable Quadrature Programmable Serial Word Vacuum Compatible ld & Serviced By: • M1000: Analog sensor with cable and sub D connector • M1200: PCB Analog sensor with output pins • M1500: Digital output sensor with cable and connector • M1500P: PCB Digital sensor with output pins • M2000: Analog sensor with cable to SS-200c interpolator • M3000: Analog sensor with cable to SS-300c interpolator • M3500: Analog sensor with cable to SS-350c interpolator • M3000SI: Analog sensor with cable to SS-300cSI interpolator. Serial word output • M3500SI: Analog sensor with cable to SS-350cSI interpolator. Serial word output • Vacuum: M1000V,M1500V,M2000V,M3000V, M3500V, M3000VSi and M3500VSi Dual Axis • ELECTROMATE er • Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com M3000SiDAA: Two analog sensors with serial word averaging interpolator M3000DAA: Two analog sensors with quadrature averaging interpolator

PowerPoint Presentation: 

Mercury Family Common Features • Single laser optical configuration • Chrome on glass scales only - Linear, full rotary and rotary segment - Index only (no left/right limits) • Modular (Any Mercury encoder can pair up with any Mercury grating) • Broad alignment tolerances • Very small sensor head • Wide selection of derivatives • CE and RoHS compliant ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com

PowerPoint Presentation: 

Mercury Analog • M1000 - Analog sensor head (M05, M10, M20) - 20µm period Sin and Cos output - 1.0Vp-p differential across a 120 Ω resistor – 20µm wide index window - Calibration required for gain and offset corrections using alignment tool - Electronics inside the DB15 connector - Same sensor head as programmable units - Up to x256 customer interpolation ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com

PowerPoint Presentation: 

Mercury Analog • M1200 - 20µm period Sin and Cos output - 1.6Vp-p differential across a 2k Ω resistor – 20µm wide index window - No gain, offset or phase corrections - 10 pins for thru-hole PCB mounting - Up to x256 interpolation with customer supplied signal corrections (gain, offset and phase) ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com

PowerPoint Presentation: 

Mercury Quadrature in the Head • ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com M1500 - Factory set resolution • x4 = 5µm • x8 = 2.5µm • x20 = 1.0µm • x40 = 0.5µm – Comparator based interpolation - 20µm wide index window – No gain, offset or phase corrections - 3 form factors • M1500S with 422 drivers in the DB15 connector • M1500H with 2x5 micro connector • M1500P with 10 pins for thru hole PCB mount – Optional alignment tools and SmartPrecision software

PowerPoint Presentation: 

Mercury Programmable Quadrature • All use the analog sensor head (M05, M10, M20) • Interpolator driven by micro and FPGA • 3 models - M2000: x4 - x256 - M3000: x4 - x1024 - M3500: x4 - x4096 • 1 LSB index pulse • Programmable interpolation and maximum output frequency • Built-in LED status indicators • Push-button calibration • SmartPrecision software required for programming ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com

PowerPoint Presentation: 

Mercury Programmable Serial Word • • • • • • • • • ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com All use the analog sensor head (M05, M10, M20) Interpolator driven by micro and FPGA 2 models - M3000Si: x1024 - M3500Si: x4096 Position word maintained in interpolator Encoder speed limited only by analog bandwidth (7.2M/s) Programmable index mode Built-in LED status indicators Push-button calibration SmartPrecision software required for programming

PowerPoint Presentation: 

Mercury Vacuum • • • • ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com All Mercury models available in vacuum compatible versions except M1200 and M1500P System: - Vacuum sensor head w/ 1.5M cable - 0.5M Atmospheric cable – Atmospheric processing electronics M1500V sensor cable is 5M with optional external cable. Rated to 10 -8 Torr

PowerPoint Presentation: 

Mercury Dual Axis Averager • All use two analog sensor heads (M05, M10, M20) • Interpolator driven by micro and FPGA • Interpolation depth: x1024 • 2 models - M3000SiDAA: Serial Word Output - M3500DAA: Quadrature Output • Provides the averaged output of two sensors or their difference (or both) • Many programmable features • Priced 25% less than two separate M3000 interpolators • USB software interface ld & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com