logging in or signing up BBS Biaggia Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINTLite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 327 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: February 11, 2008 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript ScanMeg BBS+ & ULTRA S: ScanMeg BBS+ & ULTRA S Click here for introductions Announcing the new ULTRA S Single-point Laser Scanner In addition to the models BBS+4” and 48” field of view, the ULTRA S has been introduced. Waterproof NEMA enclosure Based on the popular Baby S laser series New universal brackets for end or side mounting Stainless steel screws Industrial sealed connector Analog 4-20 mA, serial and PnP output Click here for introductionsBBS+: BBS+ With over 600 Baby S Type Laser Scanners in operation the new BBS+ with its waterproof enclosure will extend its usefulness into areas previously too severe. Current uses include: Cant height detection in front of horizontal bands, vertical gangs and resaws Veneer thickness measurement in front of composer lines Measurement of defect on stickers feeding automatic stick placers Quality Control installations in differential mode for thickness measurements Sorter control for thickness and nominal widths Fence checker for board bounce-back at trimmers Monitoring cant widths after canters or bandsaws Activation of kickers for lumber sweeps – non contact Multiple units used as a low-cost edger optimizer PNP output for impossible to locate photocell positions Manufacturing parts location BBS+ In Differential Mode: BBS+ In Differential Mode Differential mode for Quality Control Use BBS+48” at sawmill sorter and BBS+4” in planermill applications Outputs thickness directly in inches in 4-20 mA or serial Differential communication modules for single or multiple scanners in daisy chain (eg. Transverse scanning applications) Click here for commentsDifferential Communications Module(3 analog outputs 4-20mA, 2 PNP contacts, RS-485 serial communication, 2 plug-in BabyS or BBS+): Differential Communications Module (3 analog outputs 4-20mA, 2 PNP contacts, RS-485 serial communication, 2 plug-in BabyS or BBS+) BBS+ #1 BBS+ #2 Connection to next module (daisy chain) Push button to sequence through data: Scanned value from BBS+ #1 (inches) Scanned value from BBS+ #2 (inches) Differential output (thickness, inches) Module parameters Module output median adjustment LED: green = BBS+48” yellow = BBS+4” (automatic indicator when installed) Dipswitches for: Baud rate Median adjustment Data output connection to PLC or PC Display indicator status Display data for BBS+ #1, #2 differential value or module parameters Connection from previous module (daisy chain) Push button for local differential calibration Dipswitches for: Module I.D. Termination (last module)BBS+ Specifications: BBS+ SpecificationsBBS+ Universal Brackets: BBS+ Universal Brackets Selection of fastener brackets Universal End bracket (90º) Side bracket (90º or 180º) Stainless steel screws Solid aluminium block housing Slide7: BBS48 scanners used to measure differential board thickness in a Cross-beam Edger Optimizer Picture courtesy Automation & Electronics, New Zealand Type T Light-curtain Scanner Type BBS+48 (top sensors shown) Click here for commentsSlide8: BBS+48 Differential Type SE Long-range Single-point scanner (for lumber length) BBS+48 used with DIFF module to get board thickness in conjunction with the Type SE Long-range scanner to determine board length. Picture courtesy of Automation & Electronics, NZ Click here for commentsSlide9: BBS4 sensors scan the kiln stickers and eliminate those with severe twist, bow, crook, splits as well as broken ones. BBS4 used to Eliminate bad Sticks Picture courtesy of Hogue Industries Click here for commentsVeneer Application: Veneer Application Monitor veneer thickness across veneer or composed panels. DIFF Module provides thickness in inches or mm – all calculations done in on-board CPU, not in PLC or PC Daisy-chain modules together 0.001 – 0.005” precision Co-ordinates with TVeneer defect scanner for composing lines Click here for commentsBoard Length Application: Board Length Application For stud length measurement place BBS48” at each end Provides accurate length measurement through Differential module For longer boards the Type SE has a range of 4” – 14’4”Slide12: BBS48 in Differential for cants Picture courtesy of SICAM SystemsSlide13: BBS Laser scanners (3) determine log diameter for reject or sorting Type SE Laser scanner determines setback of log from log line Determination of log set back from log line and approximate log diameter for log reject, sorting or gap controlSlide14: BBS Laser point for Rough log diameter Type SE Laser scanner for setback from log line measurement Measurement of log setback and rough log diameter for oversize logs on Step-feeder or rough log diameter to help with setting appropriate gapSlide15: Two SE scanners used at different elevationsSlide16: BBS48” measures far log line BBS48” Single-point Laser ScannerSlide17: BBS48” Single-point Laser Scanner BBS48” measures far log lineSlide18: BBS48” measures near log lineSlide19: BBS48” measures near log lineSlide20: Ultra S for thickness and width after planerSlide21: Illustrating the Ultra S in Action on a planer used to continuously monitor target sizes Digital ReadoutSlide22: Concentrator Link 10 Inputs C-Link 10 TCP/IP link Encoder input Splitter Encoder signal output Programmable Encoder signal divider Serial link for configuration parameters Automatically recognizes our Single point sensors Keeps in memory all data between Sync. input signal Works in Pulse mode or window mode (Sync. signal) Connect up to 10 Single-point sensors per C-Link module Interface configuration software supplied with all modules Single-point laser concentrator Mounting LED status Sensor Input connector (1 to 6) Sensor Input connector (7 to 10) Encoder and supply connectorScanMeg: ScanMeg ScanMeg Inc. 3517 boul. Grande Allée Boisbriand, QC J7H 1H5 Canada Tel: 450.419.4555 Fax: 450.419.4542 www.scanmeg.com ScanMeg West 10972 Swan Crescent Surrey, BC V3R 5B6 Canada Tel: 604.582.2157 Fax: 604.582.2105 Contact: John Wilby jwilby@scanmeg.com You do not have the permission to view this presentation. In order to view it, please contact the author of the presentation.
BBS Biaggia Download Post to : URL : Related Presentations : Share Add to Flag Embed Email Send to Blogs and Networks Add to Channel Uploaded from authorPOINTLite Insert YouTube videos in PowerPont slides with aS Desktop Copy embed code: (To copy code, click on the text box) Embed: URL: Thumbnail: WordPress Embed Customize Embed The presentation is successfully added In Your Favorites. Views: 327 Category: Entertainment License: All Rights Reserved Like it (0) Dislike it (0) Added: February 11, 2008 This Presentation is Public Favorites: 0 Presentation Description No description available. Comments Posting comment... Premium member Presentation Transcript ScanMeg BBS+ & ULTRA S: ScanMeg BBS+ & ULTRA S Click here for introductions Announcing the new ULTRA S Single-point Laser Scanner In addition to the models BBS+4” and 48” field of view, the ULTRA S has been introduced. Waterproof NEMA enclosure Based on the popular Baby S laser series New universal brackets for end or side mounting Stainless steel screws Industrial sealed connector Analog 4-20 mA, serial and PnP output Click here for introductionsBBS+: BBS+ With over 600 Baby S Type Laser Scanners in operation the new BBS+ with its waterproof enclosure will extend its usefulness into areas previously too severe. Current uses include: Cant height detection in front of horizontal bands, vertical gangs and resaws Veneer thickness measurement in front of composer lines Measurement of defect on stickers feeding automatic stick placers Quality Control installations in differential mode for thickness measurements Sorter control for thickness and nominal widths Fence checker for board bounce-back at trimmers Monitoring cant widths after canters or bandsaws Activation of kickers for lumber sweeps – non contact Multiple units used as a low-cost edger optimizer PNP output for impossible to locate photocell positions Manufacturing parts location BBS+ In Differential Mode: BBS+ In Differential Mode Differential mode for Quality Control Use BBS+48” at sawmill sorter and BBS+4” in planermill applications Outputs thickness directly in inches in 4-20 mA or serial Differential communication modules for single or multiple scanners in daisy chain (eg. Transverse scanning applications) Click here for commentsDifferential Communications Module(3 analog outputs 4-20mA, 2 PNP contacts, RS-485 serial communication, 2 plug-in BabyS or BBS+): Differential Communications Module (3 analog outputs 4-20mA, 2 PNP contacts, RS-485 serial communication, 2 plug-in BabyS or BBS+) BBS+ #1 BBS+ #2 Connection to next module (daisy chain) Push button to sequence through data: Scanned value from BBS+ #1 (inches) Scanned value from BBS+ #2 (inches) Differential output (thickness, inches) Module parameters Module output median adjustment LED: green = BBS+48” yellow = BBS+4” (automatic indicator when installed) Dipswitches for: Baud rate Median adjustment Data output connection to PLC or PC Display indicator status Display data for BBS+ #1, #2 differential value or module parameters Connection from previous module (daisy chain) Push button for local differential calibration Dipswitches for: Module I.D. Termination (last module)BBS+ Specifications: BBS+ SpecificationsBBS+ Universal Brackets: BBS+ Universal Brackets Selection of fastener brackets Universal End bracket (90º) Side bracket (90º or 180º) Stainless steel screws Solid aluminium block housing Slide7: BBS48 scanners used to measure differential board thickness in a Cross-beam Edger Optimizer Picture courtesy Automation & Electronics, New Zealand Type T Light-curtain Scanner Type BBS+48 (top sensors shown) Click here for commentsSlide8: BBS+48 Differential Type SE Long-range Single-point scanner (for lumber length) BBS+48 used with DIFF module to get board thickness in conjunction with the Type SE Long-range scanner to determine board length. Picture courtesy of Automation & Electronics, NZ Click here for commentsSlide9: BBS4 sensors scan the kiln stickers and eliminate those with severe twist, bow, crook, splits as well as broken ones. BBS4 used to Eliminate bad Sticks Picture courtesy of Hogue Industries Click here for commentsVeneer Application: Veneer Application Monitor veneer thickness across veneer or composed panels. DIFF Module provides thickness in inches or mm – all calculations done in on-board CPU, not in PLC or PC Daisy-chain modules together 0.001 – 0.005” precision Co-ordinates with TVeneer defect scanner for composing lines Click here for commentsBoard Length Application: Board Length Application For stud length measurement place BBS48” at each end Provides accurate length measurement through Differential module For longer boards the Type SE has a range of 4” – 14’4”Slide12: BBS48 in Differential for cants Picture courtesy of SICAM SystemsSlide13: BBS Laser scanners (3) determine log diameter for reject or sorting Type SE Laser scanner determines setback of log from log line Determination of log set back from log line and approximate log diameter for log reject, sorting or gap controlSlide14: BBS Laser point for Rough log diameter Type SE Laser scanner for setback from log line measurement Measurement of log setback and rough log diameter for oversize logs on Step-feeder or rough log diameter to help with setting appropriate gapSlide15: Two SE scanners used at different elevationsSlide16: BBS48” measures far log line BBS48” Single-point Laser ScannerSlide17: BBS48” Single-point Laser Scanner BBS48” measures far log lineSlide18: BBS48” measures near log lineSlide19: BBS48” measures near log lineSlide20: Ultra S for thickness and width after planerSlide21: Illustrating the Ultra S in Action on a planer used to continuously monitor target sizes Digital ReadoutSlide22: Concentrator Link 10 Inputs C-Link 10 TCP/IP link Encoder input Splitter Encoder signal output Programmable Encoder signal divider Serial link for configuration parameters Automatically recognizes our Single point sensors Keeps in memory all data between Sync. input signal Works in Pulse mode or window mode (Sync. signal) Connect up to 10 Single-point sensors per C-Link module Interface configuration software supplied with all modules Single-point laser concentrator Mounting LED status Sensor Input connector (1 to 6) Sensor Input connector (7 to 10) Encoder and supply connectorScanMeg: ScanMeg ScanMeg Inc. 3517 boul. Grande Allée Boisbriand, QC J7H 1H5 Canada Tel: 450.419.4555 Fax: 450.419.4542 www.scanmeg.com ScanMeg West 10972 Swan Crescent Surrey, BC V3R 5B6 Canada Tel: 604.582.2157 Fax: 604.582.2105 Contact: John Wilby jwilby@scanmeg.com